Skip to main content
The search returned 5 results
Now showing 1 - 5 of 5
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: Open Access ,

    Structural Evolution of a Crustal-Scale Seismogenic Fault in a Magmatic Arc: The Bolfin Fault Zone (Atacama Fault System)

    How major crustal-scale seismogenic faults nucleate and evolve in crystalline basements represents a long-standing, but poorly understood, issue in structural geology and fault mechanics. Here, we address the spatio-temporal evolution of the Bolfin Fault Zone (BFZ), a >40-km-long exhumed seismogenic splay fault of the 1000-km-long strike-slip Atacama Fault System. The BFZ has a sinuous fault trace across the Mesozoic magmatic arc of the Coastal Cordillera (Northern Chile) and formed during the oblique subduction of the Aluk plate beneath the South American plate. Seismic faulting occurred at 5-7 km depth and ≤ 300°C in a fluid-rich environment as recorded by extensive propylitic alteration and epidote-chlorite veining. Ancient (125-118 Ma) seismicity is attested by the widespread occurrence of pseudotachylytes. Field geologic surveys indicate nucleation of the BFZ on precursory geometrical anisotropies represented by magmatic foliation of plutons (northern and central segments) and andesitic dyke swarms (southern segment) within the heterogeneous crystalline basement. Seismic faulting exploited the segments of precursory anisotropies that were optimal to favorably oriented with respect to the long-term far-stress field associated with the oblique ancient subduction. The large-scale sinuous geometry of the BFZ resulted from the hard linkage of these anisotropy-pinned segments during fault growth.
      48  115
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: Open Access ,

    Along-strike architectural variability of an exhumed crustal-scale seismogenic fault (Bolfin Fault Zone, Atacama Fault System, Chile)

    Fault zone architecture and its internal structural variability play a pivotal role in earthquake mechanics, by controlling, for instance, the nucleation, propagation and arrest of individual seismic ruptures and the evolution in space and time of foreshock and aftershock seismic sequences. Nevertheless, the along-strike architectural variability of crustal-scale seismogenic sources over regional distances is still poorly investigated. Here, we describe the architectural variability of the >40-km-long exhumed, seismogenic Bolfin Fault Zone (BFZ) of the intra-arc Atacama Fault System (Northern Chile). The BFZ cuts through plutonic rocks of the Mesozoic Coastal Cordillera and was seismically active at 5–7 km depth and ≤ 300 °C in a fluid-rich environment. The BFZ includes multiple altered fault core strands, consisting of chlorite-rich cataclasites-ultracataclasites and pseudotachylytes, surrounded by chlorite-rich protobreccias to protocataclasites over a zone up to 60-m-thick. These fault rocks are embedded within a low-strain damage zone, up to 150-m-thick, which includes strongly altered volumes of dilatational hydrothermal breccias and clusters of epidote-rich fault-vein networks at the linkage of the BFZ with subsidiary faults. The strong hydrothermal alteration of rocks along both the fault core and the damage zone attests to an extensive percolation of fluids across all the elements of the structural network during the activity of the entire fault zone. In particular, we interpret the epidote-rich fault-vein networks and associated breccias as an exhumed example of upper-crustal fluid-driven earthquake swarms, similar to the presently active intra-arc Liquiñe-Ofqui Fault System (Southern Andean Volcanic Zone, Chile).
      62  139
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: Open Access ,

    Frictional Melting in Hydrothermal Fluid-Rich Faults: Field and Experimental Evidence From the Bolfín Fault Zone (Chile)

    Tectonic pseudotachylytes are thought to be unique to certain water-deficient seismogenic environments and their presence is considered to be rare in the geological record. Here, we present field and experimental evidence that frictional melting can occur in hydrothermal fluid-rich faults hosted in the continental crust. Pseudotachylytes were found in the >40 km-long Bolfín Fault Zone of the Atacama Fault System, within two ca. 1 m-thick (ultra)cataclastic strands hosted in a damage-zone made of chlorite-epidote-rich hydrothermally altered tonalite. This alteration state indicates that hydrothermal fluids were active during the fault development. Pseudotachylytes, characterized by presenting amygdales, cut and are cut by chlorite-, epidote- and calcite-bearing veins. In turn, crosscutting relationship with the hydrothermal veins indicates pseudotachylytes were formed during this period of fluid activity. Rotary shear experiments conducted on bare surfaces of hydrothermally altered rocks at seismic slip velocities (3 m s-1) resulted in the production of vesiculated pseudotachylytes both at dry and water-pressurized conditions, with melt lubrication as the primary mechanism for fault dynamic weakening. The presented evidence challenges the common hypothesis that pseudotachylytes are limited to fluid-deficient environments, and gives insights into the ancient seismic activity of the system. Both field observations and experimental evidence, indicate that pseudotachylytes may easily be produced in hydrothermal environments, and could be a common co-seismic fault product. Consequently, melt lubrication could be considered one of the most efficient seismic dynamic weakening mechanisms in crystalline basement rocks of the continental crust.
      68  100
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: Open Access ,

    Physical state of water controls friction of gabbro-built faults

    Earthquakes often occur along faults in the presence of hot, pressurized water. Here we exploit a new experimental device to study friction in gabbro faults with water in vapor, liquid and supercritical states (water temperature and pressure up to 400 °C and 30 MPa, respectively). The experimental faults are sheared over slip velocities from 1 μm/s to 100 mm/s and slip distances up to 3 m (seismic deformation conditions). Here, we show with water in the vapor state, fault friction decreases with increasing slip distance and velocity. However, when water is in the liquid or supercritical state, friction decreases with slip distance, regardless of slip velocity. We propose that the formation of weak minerals, the chemical bonding properties of water and (elasto)hydrodynamic lubrication may explain the weakening behavior of the experimental faults. In nature, the transition of water from liquid or supercritical to vapor state can cause an abrupt increase in fault friction that can stop or delay the nucleation phase of an earthquake.
      24  135
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: Open Access ,

    Frictional power dissipation in a seismic ancient fault

    The frictional power per unit area (product of frictional traction τ and slip rate in MW m−2) dissipated during earthquakes triggers fault dynamic weakening mechanisms that control rupture nucleation, propagation and arrest. Although of great relevance in earthquake mechanics, cannot, with rare exceptions, be determined by geophysical methods. Here we exploit theoretical, experimental and geological constraints to estimate dissipated on a fault patch exhumed from 7-9 km depth. According to theoretical models, in polymineralic, silicate rocks the amplitude (< 1 mm) of the grain-scale roughness of the boundary between frictional melt (pseudotachylyte) and host rock decreases with increasing . The dependence of grain-scale roughness with is due to differential melt front migration in the host rock minerals. This dependence is confirmed by friction experiments reproducing seismic slip where pseudotachylytes were produced by shearing tonalite at ranging from 5 to 25 MW m−2. In natural pseudotachylytes across tonalites, the grain-scale roughness broadly decreases from extensional to compressional fault domains where lower and higher are expected, respectively. Analysis of the natural dataset calibrated by experiments yields values in the range of 4-60 MW m−2 (16 MW m−2 average value). These values, estimated in small fault patches, are at the lower end of broad estimates of (3-300 MW m−2) obtained from frictional tractions (30-300 MPa) and fault slip rates (0.1-1 m/s) assumed as typical of upper crustal earthquakes.
      29  212