Skip to main content
The search returned 9 results
Now showing 1 - 9 of 9
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: Open Access ,

    Stable isotope composition and airborne concentration of CO 2 in Rome capital city (Italy)

    Airborne CO2 has played a pivotal role in maintaining the Earth's atmospheric temperature at reasonable levels throughout its history. Since the onset of the industrial revolution, the level of airborne CO2 has surged due to the combustion of hydrocarbons, leading to global warming. Hydrocarbon consumption is predominantly concentrated in metropolitan areas, driven by various human activities. Estimations of CO2 emissions into the atmosphere rely on the growth of electrical power generation through hydrocarbon combustion. This study presents the outcomes of direct measurements of stable isotope concentrations in airborne CO2 in the urban area of Rome, Italy. We focused on Rome capital city, because i) it is the most populous municipality in Italy (2.8 millions inhabitants), ii) it is the European municipality with the largest surface of green areas and iii) in its south-east sector it borders the Colli Albani quiescent volcano. The dataset encompasses stable isotope compositions and airborne CO2 concentrations gathered to investigate variations in CO2 emissions across space and time. The spatial survey conducted throughout Rome's urbanized area, on a 250 km long path, aims to pinpoint the relevant sources of CO2 based on the stable isotope signature. Results reveal that the combustion of fossil fuels, stemming from urban mobility and household heating, constitutes the predominant source for the excess of airborne CO2 across a wide area of Rome centre. On the contrary, within the Rome south-east sector, including Colli Albani periphery, the carbon isotopic signature of airborne CO2 discloses the endogenous origin of the gas emissions. Continuous monitoring was carried out by the installation of an isotope analyser in three specific points of interest throughout Rome: the busiest area of the city centre, the woodland urban park of Villa Ada and the endogenous gas emission of Cava dei Selci. Findings unveil cyclic variations in human-related CO2 emissions in the city centre. The highest concentrations of airborne CO2 coincide with rush hours during morning and evening. The urban park is not affected by anthropic CO2 and its trend displays the typical day-night cycle. At Cava dei Selci we found high CO2 concentrations by a volcanic source and variations in the urban area correlate with changes in environmental conditions, such as wind speed and direction.
      12  25
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: Open Access ,

    Sullo sviluppo della rete multiparametrica in Sicilia

    This contribution illustrates the state of the art on the development of the multiparametric network in Sicily in the last three years. This region is wellknown for the strong earthquakes (M>6.5) which struck in historic time. However, the coverage of the seismic network developed in the last decades was not fully optimized to the need of the seismic surveillance. Since 2017, the group belonging to the National Earthquake Observatory (ONT) which operates in Sicily launched a developing plan of the preexisting seismic network in the framework of the project FISR “Sale Operative Integrate e Reti di Monitoraggio del futuro: l’INGV 2.0 (S.O.I.R.)”. Such update will end by the next years thanks to the project “GRINT Italian Research Infrastructure for Geosciences” in the framework of the “Programma Operativo Nazionale” (PON) of the Italian Ministry for the University and Research. This plan envisages both the upgrade of monitoring systems in the already existing nodes, and the integration of new nodes. The main objective is to build a multiparametric network which integrates the main seismic network, with the monitoring of other geophysical signals through the implementation of other sensors: accelerometers, geodetic GPS, radon detectors, and corner reflectors. We also illustrate the plan for the realization of a redundant network which could support the tasks of the main infrastructure in case of failure of the latter. Finally, we present some experimental urbanscale networks which in the future could support the main infrastructure.
      719  36
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: Open Access ,

    Sviluppo di una stazione sismica low-cost basata su tecnologia MEMS

    The impact of a strong earthqauke onto an urban community can be reduced taking timely actions managed by the authority in charge for the civil protection. In this view, it is of fundamental importance that the authority in charge for the seismic surveillance is provided with the appropriate monitoring tools able to give the most useful information for the best emergency management in the immediate postevent. Today this goal can be reached realizing urbanscale, realtime seismic monitoring networks (Osservatori Sismici Urbani, OSU, in Italian). The realtime OSU networks are able to promptly provide information to the emergency authority about the ground shaking at each node after an earthquake. Maps showing the spatial distribution of the ground shaking could help in the optimization of the priorities and a good management of the rescue resources in order to reduce the number of victims. Also the assessment of the damage of the buildings could be carried out according to the logic of priority given by the shakings measured by the OSU. The realisation of OSUs is the main objective of the MEMS project. This project is funded by the MIUR under the SIR program (Scientific Independence of young Researchers). The first challenge of the MEMS project was the design and the development of a devoted accelerometric stations. This work illustrates in detail the accelerometric station based on MEMS technology (Micro ElectroMechanical Systems). The final product is a lowcost accelerometric station with high performance and great versatility.
      931  43
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: Restricted ,

    Heat flux-based strategies for the thermal monitoring of sub-fumarolic areas: Examples from Vulcano and La Soufrière de Guadeloupe

    Although it is relatively easy to set-up, the monitoring of soil temperature in sub-fumarolic areas is quite rarely used to monitor the evolution of hydrothermal systems. Indeed, measurements are highly sensitive to environmental conditions, in particular daily and seasonal variations of atmospheric temperatures and rainfalls, which can be only partially filtered by the established statistical analysis. In this paper, we develop two innovative processingmethods, both based on the computation of the heat flux in the soil. The upward heat flux method (UHF), designed for dry environments, consists in computing both the conductive and convective components of the heat flux between two thermocouples placed vertically. In the cases of wet environments, the excess of total heat method (ETH) allows the integration of rain gauges data in order to correct the heat balance fromthe superficial cooling effect of the precipitations. The performances of both processing techniques are faced to established methods (temperature gradient and coefficient of determination) on soil temperature time series from two test volcanoes. At La Fossa di Vulcano (Italy), the UHF method undoubtedly detects three thermal crises between 2009 and 2012, enabling to quantify not only the intensity but also the precise timing of the heat flux increase with respect to corresponding geochemical and seismic crises. At La Soufrière de Guadeloupe (French Lesser Antilles), despite large rainfalls dramatically influencing the thermal behavior of the soil, a constant geothermal heat flux is retrieved by the ETH method, confirming the absence of fumarolic crisis during the observation period (February–August 2010). Being quantitative, robust, and usable in almost any context of sub-fumarolic zones, our two heat flux-based methods increase the potential of soil temperature for the monitoring, but also the general interpretation of fumarolic crises together with geochemical and seismological observations. A spreadsheet allowing direct computation of UHF and ETH is provided as supplemental material.
      367  12
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: Restricted ,

    Hydrothermal system of Central Tenerife Volcanic Complex, Canary Islands (Spain), inferred from self-potential measurements.

    An extensive self-potential survey was carried out in the central volcanic complex of Tenerife Island (Canary Islands, Spain). A total amount of ~237 kmof profileswith 20 mspacing betweenmeasurementswas completed, including radial profiles extending from the summits of Teide and Pico Viejo, and circular profiles inside and around Las Cañadas caldera and the northern slopes of Teide and Pico Viejo. One of themain results of this mapping is the detection ofwell-developed hydrothermal systemswithin the edifices of Teide and Pico Viejo, and also associated with the flank satellite M. Blanca and M. Rajada volcanoes. A strong structural control of the surface manifestation of these hydrothermal systems is deduced from the data, pointing to the subdivision of Teide and Pico Viejo hydrothermal systems in three zones: summit crater, upper and lower hydrothermal systems. Self-potential maxima related to hydrothermal activity are absent from the proximal parts of the NE and NW rift zones as well as from at least two of the mafic historical eruptions (Chinyero and Siete Fuentes), indicating that long-lived hydrothermal systems have developed exclusively over relatively shallow felsic magma reservoirs. Towards Las Cañadas caldera floor and walls, the influence of the central hydrothermal systems disappears and the self-potential signal is controlled by the topography, the distance to thewater table of Las Cañadas aquifer and its geometry. Nevertheless, fossil or remanent hydrothermal activity at some points along the Caldera wall, especially around the Roques de García area, is also suggested by the data. Self-potential data indicate the existence of independent groundwater systems in the three calderas of Ucanca, Guajara and Diego Hernández, with a funnel shaped negative anomaly in the Diego Hernández caldera floor related to the subsurface topography of the caldera bottom. Two other important self-potential features are detected: positive values towards the northwestern Santiago rift, possibly due to the relatively high altitude of the water-table in this area; and a linear set ofminima to thewest of Pico Viejo, aligned with the northwestern rift and related to meteoricwater infiltration along its fracture system.
      366  75
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: Restricted ,

    Hydrogeology of Stromboli volcano, Aeolian Islands (Italy) from the interpretation of resistivity tomograms, self-potential, soil temperature and soil CO2 concentration measurements

    To gain a better insight of the hydrogeology and the location of the main tectonic faults of Stromboli volcano in Italy, we collected electrical resistivity measurements, soil CO2 concentrations, temperature and self-potential measurements along two profiles. These two profiles started at the village of Ginostra in the southwest part of the island. The first profile (4.8 km in length) ended up at the village of Scari in the north east part of the volcano and the second one (3.5 km in length) at Forgia Vecchia beach, in the eastern part of the island. These data were used to provide insights regarding the position of shallow aquifers and the extension of the hydrothermal system. This large-scale study is complemented by two high-resolution studies, one at the Pizzo area (near the active vents) and one at Rina Grande where flank collapse areas can be observed. The Pizzo corresponds to one of the main degassing structure of the hydrothermal system. The main degassing area is localized along a higher permeability area corresponding to the head of the gliding plane of the Rina Grande sector collapse. We found that the self-potential data reveal the position of an aquifer above the villages of Scari and San Vincenzo. We provide an estimate of the depth of this aquifer from these data. The lateral extension of the hydrothermal system (resistivity ∼15–60 ohm m) is broader than anticipated extending in the direction of the villages of Scari and San Vincenzo (in agreement with temperature data recorded in shallow wells). The lateral extension of the hydrothermal system reaches the lower third of the Rina Grande sector collapse area in the eastern part of the island. The hydrothermal body in this area is blocked by an old collapse boundary. This position of the hydrothermal body is consistent with low values of the magnetization (<2.5 A m−1) from previously published work. The presence of the hydrothermal body below Rina Grande raises questions about the mechanical stability of this flank of the edifice.
      486  40
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: Restricted ,

    Adventive hydrothermal circulation on Stromboli volcano (Aeolian Islands, Italy) revealed by geophysical and geochemical approaches: Implications for general fluid flow models on volcanoes

    On March 15th 2007 a paroxysmal explosion occurred at the Stromboli volcano. This event generated a large amount of products,mostly lithic blocks, someofwhich impacted the ground as far as down to 200 m a.s.l., about 1.5 kmfaraway fromthe active vents. Two days after the explosion, a newvapouremissionwas discovered on the north-eastern flank of the volcanic edifice, at 560 m a.s.l., just above the area called “Nel Cannestrà”. This new vapour emission was due to a block impact. In order to investigate the block impact area to understand the appearance of the vapour emission, we conducted on May 2008 a multidisciplinary study involving Electrical Resistivity Tomography (ERT), Ground Penetrating Radar (GPR), Self-Potential (SP), CO2 soil diffuse degassing and soil temperature surveys. This complementary data set revealed the presence of an anomalous conductive body, probably related to a shallow hydrothermal level, at about 10–15 m depth, more or less parallel to the topography. It is the first time that such a hydrothermal fluid flow,with a temperature close to thewater boiling point (76 °C) has been evidenced at Stromboli at this low elevation on the flank of the edifice. The ERT results suggest a possible link between (1) the main central hydrothermal system of Stromboli, located just above the plumbing system feeding the active vents, with a maximum of subsurface soil temperature close to 90 °C and limited by the NeoStromboli summit crater boundary and (2) the investigated area of Nel Cannestrà, at ~500 m a.s.l., a buried eruptive fissure active 9 ka ago. In parallel, SP and CO2 soil diffuse degassingmeasurements suggest in this sector at slightly lower elevation fromthe block impact crater a magmatic and hydrothermal fluid rising system along the N41° regional fault. A complementary ERT profile, on May 2009, carried out from the NeoStromboli crater boundary downto the block impact crater displayed a flank fluid flowapparently connected to a deeper system. The concept of shallow hydrothermal level have been compared to similar ERT results recently obtained onMount Etna and La Fossa cone of Vulcano. This information needs to be taken into account in general fluid flow models on volcanoes. In particular, peripheral thermal waters (as those bordering the northeastern coast of Stromboli) could be contaminated by hydrothermal and magmatic fluids coming from regional faults but also from the summit.
      540  30
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: Open Access ,

    New geological insights and structural control on fluid circulation in La Fossa cone (Vulcano, Aeolian Islands, Italy)

    Electric resistivity tomography (ERT), self-potential (SP), soil CO2 flux, and temperature are used to study the inner structure of La Fossa cone (Vulcano, Aeolian Islands). Nine profiles were performed across the cone with a measurement spacing of 20 m. The crater rims of La Fossa cone are underlined by sharp horizontal resistivity contrasts. SP, CO2 flux, and temperature anomalies underline these boundaries which we interpret as structural limits associated to preferential circulation of fluids. The Pietre Cotte crater and Gran Cratere crater enclose the main hydrothermal system, identified at the centre of the edifice on the base of low electrical resistivity values (b20 Ω m) and strong CO2 degassing, SP, and temperature anomalies. In the periphery, the hydrothermal activity is also visible along structural boundaries such as the Punte Nere, Forgia Vecchia, and Palizzi crater rims and at the base of the cone, on the southern side of the edifice, along a fault attributed to the NW main tectonic trend of the island. Inside the Punte Nere crater, the ERT sections show an electrical resistive body that we interpret as an intrusion or a dome. This magmatic body is reconstructed in 3D using the available ERT profiles. Its shape and position, with respect to the Pietre Cotte crater fault, allows replacing this structure in the chronology of the development of the volcano. It corresponds to a late phase of activity of the Punte Nere edifice. Considering the position of the SP, soil CO2 flux, and temperature maxima and the repartition of conductive zones related to hydrothermal circulation with respect to the main structural features, La Fossa cone could be considered as a relevant example of the strong influence of preexisting structures on hydrothermal fluid circulation at the scale of a volcanic edifice.
      601  1678
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: Restricted ,

    Continuous soil CO2 and discrete plume SO2 measurements at Mt. Etna (Italy) during 1997-2000: a contribution to volcano monitoring

    Continuous monitoring of soil CO2 dynamic concentration (which is proportional to the CO2 flux through the soil) was carried out at a peripheral site of Mt. Etna during the period November 1997 - September 2000 using an automated station. The acquired data were compared with SO2 flux from the summit craters measured two to three times a week during the same period. The high frequency of data acquisition with both methods allowed us to analyze in detail the time variations of both parameters. Anomalous high values of soil CO2 dynamic concentration always preceded periods of increased flux of plume SO2, and these in turn were followed by periods of summit eruptions. The variations were modeled in terms of gas efflux increase due to magma ascent to shallow depth and its consequent depressurization and degassing. This model is supported by data from other geophysical and volcanological parameters. The rates of increase both of soil CO2 dynamic concentration and of plume SO2 flux are interpreted to be positively correlated both to the velocity of magma ascent within the volcano and to lava effusion rate once magma is erupted at the surface. Low rates of the increase were recorded before the nine-month-long 1999 subterminal eruption. Higher rates of increase were observed before the violent summit eruption of September-November 1999, and the highest rates were observed during shorter and very frequent spike-like anomalies that preceded the sequence of short-lived but very violent summit eruptions that started in late January 2000 and continued until late June of the same year. Furthermore, the time interval between the peaks of CO2 and SO2 in a single sequence of gas anomalies is likely to be controlled by magma ascent velocity.
      252  107