Skip to main content
The search returned 6 results
Now showing 1 - 6 of 6
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: Restricted ,

    Small-scale spatial variability of soil CO2 flux: Implication for monitoring strategy

    In recent decades, soil CO2 flux measurements have been often used in both volcanic and seismically active areas to investigate the interconnections between temporal and spatial anomalies in degassing and telluric activities. In this study, we focus on a narrow degassing area of the Piton de la Fournaise volcano, that has been chosen for its proximity and link with the frequently active volcanic area. Our aim is to constrain the degassing in this narrow area and identify the potential processes involved in both spatial and temporal soil CO2 variations in order to provide an enhanced monitoring strategy for soil CO2 flux. We performed a geophysical survey (self-potential measurements: SP; electrical resistivity tomography: ERT) to provide a high-resolution description of the subsurface. We identified one main SP negative anomaly dividing the area in two zones. Based on these results, we set ten control points, from the site of the main SP negative anomaly up to 230 m away, where soil CO2 fluxes were weekly measured during one year of intense eruptive activity at Piton de la Fournaise. Our findings show that lateral and vertical soil heterogeneities and structures exert a strong control on the degassing pattern. We find that temporal soil CO2 flux series at control points close to the main SP negative anomaly better record variations linked to the volcanic activity. We also show that the synchronicity between the increase of soil CO2 flux and deep seismicity can be best explained by a pulsed process pushing out the CO2 already stored and fractionated in the system. Importantly, our findings show that low soil CO2 fluxes and low carbon isotopic signature are able to track variations of volcanic activity in the same way as high fluxes and high carbon isotopic signature do. This result gives important insights in terms of monitoring strategy of volcanic and seismotectonic areas in geodynamics contexts characterized by difficult environmental operational conditions as commonly met in tropical area
      364  7
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: Restricted ,

    Heat flux-based strategies for the thermal monitoring of sub-fumarolic areas: Examples from Vulcano and La Soufrière de Guadeloupe

    Although it is relatively easy to set-up, the monitoring of soil temperature in sub-fumarolic areas is quite rarely used to monitor the evolution of hydrothermal systems. Indeed, measurements are highly sensitive to environmental conditions, in particular daily and seasonal variations of atmospheric temperatures and rainfalls, which can be only partially filtered by the established statistical analysis. In this paper, we develop two innovative processingmethods, both based on the computation of the heat flux in the soil. The upward heat flux method (UHF), designed for dry environments, consists in computing both the conductive and convective components of the heat flux between two thermocouples placed vertically. In the cases of wet environments, the excess of total heat method (ETH) allows the integration of rain gauges data in order to correct the heat balance fromthe superficial cooling effect of the precipitations. The performances of both processing techniques are faced to established methods (temperature gradient and coefficient of determination) on soil temperature time series from two test volcanoes. At La Fossa di Vulcano (Italy), the UHF method undoubtedly detects three thermal crises between 2009 and 2012, enabling to quantify not only the intensity but also the precise timing of the heat flux increase with respect to corresponding geochemical and seismic crises. At La Soufrière de Guadeloupe (French Lesser Antilles), despite large rainfalls dramatically influencing the thermal behavior of the soil, a constant geothermal heat flux is retrieved by the ETH method, confirming the absence of fumarolic crisis during the observation period (February–August 2010). Being quantitative, robust, and usable in almost any context of sub-fumarolic zones, our two heat flux-based methods increase the potential of soil temperature for the monitoring, but also the general interpretation of fumarolic crises together with geochemical and seismological observations. A spreadsheet allowing direct computation of UHF and ETH is provided as supplemental material.
      367  12
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: Restricted ,

    Deep electrical resistivity tomography along the tectonically active Middle Aterno Valley (2009 L'Aquila earthquake area, central Italy)

    Three 2-D Deep Electrical Resistivity Tomography (ERT) transects, up to 6.36 km long, were obtained across the Paganica-San Demetrio Basin, bounded by the 2009 L’Aquila Mw 6.1 normal-faulting earthquake causative fault (central Italy). The investigations allowed defining for the first time the shallow subsurface basin structure. The resistivity images, and their geological interpretation, showa dissected Mesozoic-Tertiary substratum buried under continental infill of mainly Quaternary age due to the long-term activity of the Paganica-San Demetrio normal faults system (PSDFS), ruling the most recent deformational phase. Our results indicate that the basin bottom deepens up to 600 m moving to the south, with the continental infill largely exceeding the known thickness of the Quaternary sequence. The causes of this increasing thickness can be: (1) the onset of the continental deposition in the southern sector took place before the Quaternary, (2) there was an early stage of the basin development driven by different fault systems that produced a depocentre in the southern sector not related to the present-day basin shape, or (3) the fault system slip rate in the southern sector was faster than in the northern sector. We were able to gain sights into the long-term PSDFS behaviour and evolution, by comparing throw rates at different timescales and discriminating the splays that lead deformation. Some fault splays exhibit large cumulative throws (>300 m) in coincidence with large displacement of the continental deposits sequence (>100 m), thus testifying a general persistence in time of their activity as leading splays of the fault system. We evaluate the long-term (3–2.5Myr) cumulative and Quaternary throw rates of most of the leading splays to be 0.08–0.17 mm yr−1, indicating a substantial stability of the faults activity. Among them, an individual leading fault splay extends from Paganica to San Demetrio ne’ Vestini as a result of a post-Early Pleistocene linkage of two smaller splays. This 15 km long fault splay can explain the Holocene surface ruptures observed to be larger than those occurred during the 2009 L’Aquila earthquake, such as revealed by palaeoseismological investigations. Finally, the architecture of the basin at depth suggests that the PSDFS can also rupture a longer structure at the surface, allowing earthquakes larger than M 6.5, besides rupturing only small sections, as it occurred in 2009.
      286  5
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: Open Access ,

    Hydrothermal fluid flow disruptions evidenced by subsurface changes in heat transfer modality: The La Fossa cone of Vulcano (Italy) case study

    Detecting volcanic unrest is of primary importance for eruption forecasting, especially on volcanoes characterized by highly dangerous, and often seemingly unpredictable, phreatic or phreatomagmatic eruptions. We present a simple and innovative analysis of shallow vertical temperature profiles to depths of 70 cm. These data were recorded at La Fossa cone of Vulcano (Aeolian Islands, Italy), during an episode of increased hydrothermal and seismic activities that occurred between September and December 2009. This work involves the use of the coefficient of determination (R-2) on vertical temperature profiles in order to identify changes in conductive versus convective heat transfer modality. The increase in convective heat transfer can be related to the disruption of the hydrothermal system due to its pressurization and/or variation of ground permeability between the hydrothermal system and the surface. While raw temperature data do not evidence any significant variation during the period investigated and the classic temperature gradient is highly influenced by seasonal variations, the fluctuation of R-2 displayed striking spikes that coincided with the seismic swarm inside the volcanic edifice. Such a low-cost device associated with easy real-time data processing could constitute a very promising, yet deceptively simple, technique to monitor hydrothermal systems, in order to assess the hazard posed by high-energy eruptions for populations living close to active volcanoes.
      384  95
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: Restricted ,

    Hydrogeology of Stromboli volcano, Aeolian Islands (Italy) from the interpretation of resistivity tomograms, self-potential, soil temperature and soil CO2 concentration measurements

    To gain a better insight of the hydrogeology and the location of the main tectonic faults of Stromboli volcano in Italy, we collected electrical resistivity measurements, soil CO2 concentrations, temperature and self-potential measurements along two profiles. These two profiles started at the village of Ginostra in the southwest part of the island. The first profile (4.8 km in length) ended up at the village of Scari in the north east part of the volcano and the second one (3.5 km in length) at Forgia Vecchia beach, in the eastern part of the island. These data were used to provide insights regarding the position of shallow aquifers and the extension of the hydrothermal system. This large-scale study is complemented by two high-resolution studies, one at the Pizzo area (near the active vents) and one at Rina Grande where flank collapse areas can be observed. The Pizzo corresponds to one of the main degassing structure of the hydrothermal system. The main degassing area is localized along a higher permeability area corresponding to the head of the gliding plane of the Rina Grande sector collapse. We found that the self-potential data reveal the position of an aquifer above the villages of Scari and San Vincenzo. We provide an estimate of the depth of this aquifer from these data. The lateral extension of the hydrothermal system (resistivity ∼15–60 ohm m) is broader than anticipated extending in the direction of the villages of Scari and San Vincenzo (in agreement with temperature data recorded in shallow wells). The lateral extension of the hydrothermal system reaches the lower third of the Rina Grande sector collapse area in the eastern part of the island. The hydrothermal body in this area is blocked by an old collapse boundary. This position of the hydrothermal body is consistent with low values of the magnetization (<2.5 A m−1) from previously published work. The presence of the hydrothermal body below Rina Grande raises questions about the mechanical stability of this flank of the edifice.
      486  40
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: Restricted ,

    Adventive hydrothermal circulation on Stromboli volcano (Aeolian Islands, Italy) revealed by geophysical and geochemical approaches: Implications for general fluid flow models on volcanoes

    On March 15th 2007 a paroxysmal explosion occurred at the Stromboli volcano. This event generated a large amount of products,mostly lithic blocks, someofwhich impacted the ground as far as down to 200 m a.s.l., about 1.5 kmfaraway fromthe active vents. Two days after the explosion, a newvapouremissionwas discovered on the north-eastern flank of the volcanic edifice, at 560 m a.s.l., just above the area called “Nel Cannestrà”. This new vapour emission was due to a block impact. In order to investigate the block impact area to understand the appearance of the vapour emission, we conducted on May 2008 a multidisciplinary study involving Electrical Resistivity Tomography (ERT), Ground Penetrating Radar (GPR), Self-Potential (SP), CO2 soil diffuse degassing and soil temperature surveys. This complementary data set revealed the presence of an anomalous conductive body, probably related to a shallow hydrothermal level, at about 10–15 m depth, more or less parallel to the topography. It is the first time that such a hydrothermal fluid flow,with a temperature close to thewater boiling point (76 °C) has been evidenced at Stromboli at this low elevation on the flank of the edifice. The ERT results suggest a possible link between (1) the main central hydrothermal system of Stromboli, located just above the plumbing system feeding the active vents, with a maximum of subsurface soil temperature close to 90 °C and limited by the NeoStromboli summit crater boundary and (2) the investigated area of Nel Cannestrà, at ~500 m a.s.l., a buried eruptive fissure active 9 ka ago. In parallel, SP and CO2 soil diffuse degassingmeasurements suggest in this sector at slightly lower elevation fromthe block impact crater a magmatic and hydrothermal fluid rising system along the N41° regional fault. A complementary ERT profile, on May 2009, carried out from the NeoStromboli crater boundary downto the block impact crater displayed a flank fluid flowapparently connected to a deeper system. The concept of shallow hydrothermal level have been compared to similar ERT results recently obtained onMount Etna and La Fossa cone of Vulcano. This information needs to be taken into account in general fluid flow models on volcanoes. In particular, peripheral thermal waters (as those bordering the northeastern coast of Stromboli) could be contaminated by hydrothermal and magmatic fluids coming from regional faults but also from the summit.
      539  30