dc.description.abstractIn order to evaluate detection and localization capabilities of a future array in the Upper Tiber Valley (Northern Apennines – Italy), an irregularly configured test array was installed near Città di Castello (CDC) for a period of two weeks, consisting of nine sites with inter-sensor distances between 150 and 2200 m. This test-array installation is particular in its use of three component sensors at all array sites, which allows the application of all array specific analyses techniques for the full seismic wavefield, i.e., also for horizontal-component data. In this study we investigate the inter-sensor coherence of the seismic noise field for the test-array area. In addition to the “classic” noise analysis, where noise cross-correlation values are calculated at single vertical instruments without relative time shifts between the traces, we extend the study by a “dynamic” approach, which accounts for possible slowness characteristics of the noise field. Furthermore, we investigate how the noise characteristics are dependent on the chosen component of the seismic sensors, by analyzing the noise coherence not only between vertical components but also on the radial and the transverse components. The coherence found for noise observed by the different sensors of the test array shows strong azimuthal variations on all components, which are most pronounced for noise within the frequency passband of 1.5 - 4.0 Hz and an apparent velocity of 1.5 km/s (Rg waves). The calculated correlation lengths of noise observed for the CDC array are about half of the values found for the NORES array in Southern Norway. Therefore, a future permanent array installation should be planned for minimum inter-sensor distances between 150 and 200 m.en
dc.language.isoEnglishen
dc.publisher.nameSeismological Society of Americaen
dc.relation.ispartofBulletin Seismological Society Americaen
dc.relation.ispartofseries4/98 (2008)en
dc.subjectseismic arrayen
dc.subjectnoise fielden
dc.titleSpatial Noise-Field Characteristics of a Temporary Three-Component Small Aperture Array in Central Italyen
dc.typearticleen
dc.description.statusPublisheden
dc.type.QualityControlPeer-revieweden
dc.description.pagenumber1876-1886en
dc.subject.INGV04. Solid Earth::04.06. Seismology::04.06.10. Instruments and techniquesen
dc.identifier.doi10.1785/0120070077en
dc.description.obiettivoSpecifico1.1. TTC - Monitoraggio sismico del territorio nazionaleen
dc.description.journalTypeJCR Journalen
dc.description.fulltextopenen
dc.contributor.authorBraun, T.en
dc.contributor.authorSchweitzer, J.en
dc.contributor.departmentIstituto Nazionale di Geofisica e Vulcanologia, Sezione Roma1, Roma, Italiaen
dc.contributor.departmentNORSAR-Kjelleren
item.openairetypearticle-
item.cerifentitytypePublications-
item.languageiso639-1en-
item.grantfulltextopen-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.fulltextWith Fulltext-
crisitem.author.deptIstituto Nazionale di Geofisica e Vulcanologia (INGV), Sezione Roma1, Roma, Italia-
crisitem.author.orcid0000-0003-1778-1328-
crisitem.author.parentorgIstituto Nazionale di Geofisica e Vulcanologia-
crisitem.classification.parent04. Solid Earth-
crisitem.department.parentorgIstituto Nazionale di Geofisica e Vulcanologia-
Appears in Collections:Article published / in press
Files in This Item:
File Description SizeFormat
BSSA_2007077_final.pdf949.86 kBAdobe PDFView/Open
Show simple item record

WEB OF SCIENCETM
Citations 50

4
checked on Feb 7, 2021

Page view(s)

105
checked on Apr 24, 2024

Download(s) 50

97
checked on Apr 24, 2024

Google ScholarTM

Check

Altmetric