ACTIVE FAULTS AND RELATED HAZARDS: NEW INSIGHTS ON THE CENTRAL APENNINE SEISMOTECTONICS AND SURFACE FAULTING ZONATION
Author(s)
Language
English
Obiettivo Specifico
2T. Deformazione crostale attiva
Status
Published
JCR Journal
JCR Journal
Peer review journal
Yes
Issue/vol(year)
Special Issue 2019/ (2019)
Pages (printed)
79-83
Date Issued
2019
Abstract
The term active and capable fault (ACF) defines an active
tectonic structure able to rupture permanently the ground
surface. When an ACF represents the expression at surface of a
seismogenic source, the study of an ACF involves a twofold
aspect: one concerns surface faulting hazard, with engineering
implications regarding infrastructures crossing the trace of a
ACF, the other concerns the definition of geometric and
kinematic characteristics of seismogenic sources, with
implications regarding the definition of the seismogenic
potential of a given active tectonic structure. Here, we show the
results of geological investigations regarding two case studies
in the central Apennines. The first site is located near the
village of Venere dei Marsi (AQ), where the detailed
characterization of geometry and kinematics of a fault splay
connected to “San Benedetto dei Marsi – Gioia dei Marsi”
active fault segment, allowed us to verify the effectiveness of
the ACF territory zonation proposed in “Guidelines for the
management of territories affected by Active and Capable
Faults” promulgated by the Dipartimento della Protezione
Civile Nazionale of Italy in 2015. The second case study is
located close to Preci (PG), where field geological
investigations were aimed to verify the presence of an ACF in
the area of the Sant’Eutizio Abbey severely damaged by the 30
October 2016 Mw 6.5 seismic event, for retrofitting activities,
and to characterize the Campi fault segment in terms of recent
activity. This allowed to better define the geometric and
kinematic characteristics of seismogenic source, responsible for
the 2 February 1703 (Mw = 6.8), nucleated by the Norcia
active faults system.
tectonic structure able to rupture permanently the ground
surface. When an ACF represents the expression at surface of a
seismogenic source, the study of an ACF involves a twofold
aspect: one concerns surface faulting hazard, with engineering
implications regarding infrastructures crossing the trace of a
ACF, the other concerns the definition of geometric and
kinematic characteristics of seismogenic sources, with
implications regarding the definition of the seismogenic
potential of a given active tectonic structure. Here, we show the
results of geological investigations regarding two case studies
in the central Apennines. The first site is located near the
village of Venere dei Marsi (AQ), where the detailed
characterization of geometry and kinematics of a fault splay
connected to “San Benedetto dei Marsi – Gioia dei Marsi”
active fault segment, allowed us to verify the effectiveness of
the ACF territory zonation proposed in “Guidelines for the
management of territories affected by Active and Capable
Faults” promulgated by the Dipartimento della Protezione
Civile Nazionale of Italy in 2015. The second case study is
located close to Preci (PG), where field geological
investigations were aimed to verify the presence of an ACF in
the area of the Sant’Eutizio Abbey severely damaged by the 30
October 2016 Mw 6.5 seismic event, for retrofitting activities,
and to characterize the Campi fault segment in terms of recent
activity. This allowed to better define the geometric and
kinematic characteristics of seismogenic source, responsible for
the 2 February 1703 (Mw = 6.8), nucleated by the Norcia
active faults system.
Type
article
File(s)![]()
Name
MACERONI_10_09_2019[486].pdf
Size
620.94 KB
Format
Adobe PDF
Checksum (MD5)
The MD5 message-digest algorithm can be used to verify the integrity of the file that you have uploaded. You can calculate its value locally via tools that are generally available in each operative system like md5sum
be3a7728f00ccd0dacf18f2a3fc0df1b
