Study of the cosmic muon rate nearby the Advanced Virgo detector at the end of the O3 run
Author(s)
Language
English
Obiettivo Specifico
OSA3 Meteorologia spaziale e Osservazione della Terra dallo Spazio, sviluppo di tecnologie spaziali
Status
Published
JCR Journal
N/A or not JCR
Peer review journal
Yes
Journal
Issue/vol(year)
/398 (2022)
ISSN
1824-8039
Publisher
Sissa
Pages (printed)
059
Date Issued
2022
Subjects
Abstract
Cosmic-ray particles have long been studied as a potential source of noise for interferometric
gravitational-wave detectors. These particles, mostly muons at sea level, can interact with the
detector mirrors inducing thermal effects, which, at the detector output, could be observed as
transient excesses of noise, namely glitches. For the Advanced Virgo detector, the rate of these
particles is monitored by a muon telescope located in the vicinity of the detector central building.
We present here the correlation study of the rate of muons with the rate of glitches during a couple
of weeks at the end of the third joint LIGO-Virgo observing, O3. We also present the correlation
of the previous quantities with other environmental effects, showing how the latter dominate the
glitch rate and can explain a significant part of its variations.
gravitational-wave detectors. These particles, mostly muons at sea level, can interact with the
detector mirrors inducing thermal effects, which, at the detector output, could be observed as
transient excesses of noise, namely glitches. For the Advanced Virgo detector, the rate of these
particles is monitored by a muon telescope located in the vicinity of the detector central building.
We present here the correlation study of the rate of muons with the rate of glitches during a couple
of weeks at the end of the third joint LIGO-Virgo observing, O3. We also present the correlation
of the previous quantities with other environmental effects, showing how the latter dominate the
glitch rate and can explain a significant part of its variations.
Type
article
File(s)![]()
Name
EPS-HEP2021_059.pdf
Description
Open Access Published Article
Size
377.68 KB
Format
Adobe PDF
Checksum (MD5)
The MD5 message-digest algorithm can be used to verify the integrity of the file that you have uploaded. You can calculate its value locally via tools that are generally available in each operative system like md5sum
d09a2ae23b6bef75561d177faba04afd