The shallow structure of a surface-rupturing fault in unconsolidated deposits from multi-scale electrical resistivity data: The 30 October 2016 Mw 6.5 central Italy earthquake case study
Language
English
Obiettivo Specifico
1T. Deformazione crostale attiva
2TR. Ricostruzione e modellazione della struttura crostale
Status
Published
JCR Journal
JCR Journal
Peer review journal
Yes
Journal
Issue/vol(year)
/717 (2017)
Pages (printed)
628-644
Date Issued
2017
Abstract
We report the results of a shallow electrical resistivity investigation performed across a normal fault that ruptured the surface displacingwith average ~0.05mvertical offset alluvial fan deposits (b23 kyr old) within an intermontane fault-bounded basin following the 30 October 2016Mw6.5 earthquake in central Italy.Weadopted a multi-scale geophysical approach, by acquiring three 2-D electrical resistivity tomography (ERT) profiles centred on the coseismic ruptures, and characterized by different spatial resolution and investigation depth. Below the fault scarp, the ERT models show a narrow (~10 m wide) and steeply-dipping moderately-resistive region (100–150 Ωm), which we interpret as the electrical response of the fault zone displacing layers of relatively high-resistivity (300–700 Ωm) values. We explain the electrical signature of the retrieved fault zone as due to an increment of permeability caused by coseismic fracturing, and to the subsequent water migration from adjacent shallow aquifers squeezed by compaction induced by seismic waves. By using a statistically-based classification of electrical units, we estimate that the shallowest alluvial fan layer is affected by 2.7 ± 0.9 m vertical offset,which is consistentwith the measured 2.3–2.8mmorphologic offset of the top fan surface, and suggesting a post-12 kyr throw-rate of 0.23± 0.08 mm/yr. Similarly, we evaluate a post-23 kyr throw of 5.1 ± 1.7 m, indicating a Late Pleistocene throw-rate of 0.22 ± 0.07 mm/yr, in accordance with available paleoseismic data. We further hypothesize a minimal total fault throw N30 m, which likely accrued since the Middle Pleistocene (possibly in the last 350–500 kyr). The investigated fault structure is therefore an important splay characterized by a thick and highly permeable damage zone in unconsolidated deposits, andwhich ruptured the surface during several tens of strong (M N 6) earthquakes.
Type
article
File(s)![]()
![]()
Name
Villani and Sapia_TECTO_2017.pdf
Size
5.33 MB
Format
Adobe PDF
Checksum (MD5)
The MD5 message-digest algorithm can be used to verify the integrity of the file that you have uploaded. You can calculate its value locally via tools that are generally available in each operative system like md5sum
b2bf0f9bfb4e7b02305444a6af9dd5d0
Name
TECTO11880R2.pdf
Description
Open Access
Size
8.44 MB
Format
Adobe PDF
Checksum (MD5)
The MD5 message-digest algorithm can be used to verify the integrity of the file that you have uploaded. You can calculate its value locally via tools that are generally available in each operative system like md5sum
423162e9e7f27fa8d849df11ab159691
