Siracusano, Giulio
Preferred name
Siracusano, Giulio
ORCID
8 results
Filters
Settings
The search returned 8 results
Now showing 1 - 8 of 8
- Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: Open Access , Ultra-sensitive voltage-controlled skyrmion-based spintronic diode
We have designed a passive spintronic diode based on a single skyrmion stabilized in a magnetic tunnel junction and studied its dynamics induced by voltage-controlled magnetic anisotropy (VCMA) and Dzyaloshinskii-Moriya interaction (VDMI). We have demonstrated that the sensitivity (rectified output voltage over input microwave power) with realistic physical parameters and geometry can be larger than 10 kV W-1which is one order of magnitude larger than diodes employing a uniform ferromagnetic state. Our numerical and analytical results on the VCMA and VDMI-driven resonant excitation of skyrmions beyond the linear regime reveal a frequency dependence on the amplitude and no efficient parametric resonance. Skyrmions with a smaller radius produced higher sensitivities, demonstrating the efficient scalability of skyrmion-based spintronic diodes. These results pave the way for designing passive ultra-sensitive and energy efficient skyrmion-based microwave detectors.35 130 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: Open Access , Effective processing pipeline PACE 2.0 for enhancing chest x‑ray contrast and diagnostic interpretability
Preprocessing is an essential task for the correct analysis of digital medical images. In particular, X-ray imaging might contain artifacts, low contrast, diffractions or intensity inhomogeneities. Recently, we have developed a procedure named PACE that is able to improve chest X-ray (CXR) images including the enforcement of clinical evaluation of pneumonia originated by COVID-19. At the clinical benchmark state of this tool, there have been found some peculiar conditions causing a reduction of details over large bright regions (as in ground-glass opacities and in pleural effusions in bedridden patients) and resulting in oversaturated areas. Here, we have significantly improved the overall performance of the original approach including the results in those specific cases by developing PACE2.0. It combines 2D image decomposition, non-local means denoising, gamma correction, and recursive algorithms to improve image quality. The tool has been evaluated using three metrics: contrast improvement index, information entropy, and effective measure of enhancement, resulting in an average increase of 35% in CII, 7.5% in ENT, 95.6% in EME and 13% in BRISQUE against original radiographies. Additionally, the enhanced images were fed to a pre-trained DenseNet-121 model for transfer learning, resulting in an increase in classification accuracy from 80 to 94% and recall from 89 to 97%, respectively. These improvements led to a potential enhancement of the interpretability of lesion detection in CXRs. PACE2.0 has the potential to become a valuable tool for clinical decision support and could help healthcare professionals detect pneumonia more accurately.30 101 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: Open Access , Role of magnetic skyrmions for the solution of the shortest path problem
Magnetic skyrmions are emerging as key elements of unconventional operations having unique properties such as small size and low current manipulation. In particular, it is possible to design skyrmion-based neurons and synapses for neuromorphic computing in devices where skyrmions move along the current direction (zero skyrmion Hall angle). Here, we show that, for a given graph, skyrmions can be used in optimization problems facing the calculation of the shortest path. Our tests show a solution with the same path length as computed with Algorithm. In addition, we also discuss how skyrmions act as positive feedback on this type of problem giving rise to a self-reinforcement of the path which is a possible solution.41 126 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: Open Access , Pipeline for Advanced Contrast Enhancement (PACE) of Chest X-ray in Evaluating COVID-19 Patients by Combining Bidimensional Empirical Mode Decomposition and Contrast Limited Adaptive Histogram Equalization (CLAHE)
(2020-10-16); ; ; ; COVID-19 is a new pulmonary disease which is driving stress to the hospitals due to the large number of cases worldwide. Imaging of lungs can play a key role in the monitoring of health status. Non-contrast chest computed tomography (CT) has been used for this purpose, mainly in China, with significant success. However, this approach cannot be massively used, mainly for both high risk and cost, also in some countries, this tool is not extensively available. Alternatively, chest X-ray, although less sensitive than CT-scan, can provide important information about the evolution of pulmonary involvement during the disease; this aspect is very important to verify the response of a patient to treatments. Here, we show how to improve the sensitivity of chest X-ray via a nonlinear post-processing tool, named PACE (Pipeline for Advanced Contrast Enhancement), combining properly Fast and Adaptive Bidimensional Empirical Mode Decomposition (FABEMD) and Contrast Limited Adaptive Histogram Equalization (CLAHE). The results show an enhancement of the image contrast as confirmed by three widely used metrics: (i) contrast improvement index, (ii) entropy, and (iii) measure of enhancement. This improvement gives rise to a detectability of more lung lesions as identified by two radiologists, who evaluated the images separately, and confirmed by CT-scans. The results show this method is a flexible and an e ective approach for medical image enhancement and can be used as a post-processing tool for medical image understanding and analysis.120 58 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: Open Access , Spin-orbit torque based physical unclonable function
(2020-07-15); ; ; ; This paper introduces the concept of spin-orbit-torque-MRAM (SOT-MRAM) based physical unclonable function (PUF). The secret of the PUF is stored into a random state of a matrix of perpendicular SOT-MRAMs. Here, we show experimentally and with micromagnetic simulations that this random state is driven by the intrinsic nonlinear dynamics of the free layer of the memory excited by the SOT. In detail, a large enough current drives the magnetization along an in-plane direction. Once the current is removed, the in-plane magnetic state becomes unstable evolving towards one of the two perpendicular stable configurations randomly. In addition, an hybrid CMOS/spintronics model is used to evaluate the electrical characteristics of a PUF realized with an array of 16x16 SOT-MRAM cells. Beyond robustness against voltage and temperature variations, hardware authentication based on this PUF scheme has additional advantages over other PUF technologies such as non-volatility (no power consumption in standby mode), reconfigurability (the secret can be rewritten), and scalability. We believe that this work is a step forward the design of spintronic devices for application in security.183 47 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: Restricted , Micromagnetic understanding of the skyrmion Hall angle current dependence in perpendicular magnetized ferromagnets
The understanding of the dynamical properties of skyrmion is a fundamental aspect for the realization of a competitive skyrmion based technology beyond CMOS. Most of the theoretical approaches are based on the approximation of a rigid skyrmion. However, thermal fluctuations can drive a continuous change of the skyrmion size via the excitation of thermal modes. Here, by taking advantage of the Hilbert-Huang transform, we demonstrate that at least two thermal modes can be excited which are non-stationary in time. In addition, one limit of the rigid skyrmion approximation is that this hypothesis does not allow for correctly describing the recent experimental evidence of skyrmion Hall angle dependence on the amplitude of the driving force, which is proportional to the injected current. In this work, we show that, in an ideal sample, the combined effect of field-like and damping-like torques on a breathing skyrmion can indeed give rise to such a current dependent skyrmion Hall angle. While here we design and control the breathing mode of the skyrmion, our results can be linked to the experiments by considering that the thermal fluctuations and/or disorder can excite the breathing mode. We also propose an experiment to validate our findings.205 2 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: Restricted , Micromagnetic Analysis of Statistical Switching in Perpendicular Magnetic Tunnel Junctions With Double Reference Layers
The recent technological realization of perpendicular magnetic tunnel junctions (MTJs) with two reference layers has opened a new route for scaling the overall size of spin-transfer torque magnetic random-access memory. This is because, for an antiparallel configuration of the magnetization of the reference layers, the two spin-transfer torques add constructively, giving rise to more efficient switching processes of the free layer magnetization as compared to a single MTJ. We use full micromagnetic simulations to study the magnetization switching of a double MTJ. The probability distribution function (PDF) of the switching time is the same for both switching processes (parallel to antiparallel and vice versa), and the PDF approaches a Gaussian shape for switching time smaller than 1 ns. The dynamical performance (achieved for switching time below 1 ns) of double MTJs with circular shape and diameter ranging from 30 to 14 nm is comparable. Compared to full micromagnetic data, computations of the PDF within the macrospin approximation show an overestimation of the skewness for MTJ with circular shape and diameter of 30 and 20 nm, whereas they are very close for 14 nm diameter, as expected. The proper micromagnetic model and a PDF comparison can drive the design of hybrid magnetic-CMOS systems.38 1 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: Restricted , On the R2⁎ relaxometry in complex multi-peak multi-Echo chemical shift-based water-fat quantification: Applications to the neuromuscular diseases
Investigation of the feasibility of the R2⁎ mapping techniques by using latest theoretical models corrected for confounding factors and optimized for signal to noise ratio.49 4
