Effective processing pipeline PACE 2.0 for enhancing chest x‑ray contrast and diagnostic interpretability
Author(s)
Language
English
Obiettivo Specifico
OSA1 Variazioni del campo magnetico terrestre, imaging crostale e sicurezza del territorio
Status
Published
JCR Journal
JCR Journal
Peer review journal
Yes
Journal
Issue/vol(year)
/13 (2023)
ISSN
2045-2322
Publisher
Nature PG
Pages (printed)
22471
Date Issued
2023
Abstract
Preprocessing is an essential task for the correct analysis of digital medical images. In particular,
X-ray imaging might contain artifacts, low contrast, diffractions or intensity inhomogeneities.
Recently, we have developed a procedure named PACE that is able to improve chest X-ray (CXR)
images including the enforcement of clinical evaluation of pneumonia originated by COVID-19. At
the clinical benchmark state of this tool, there have been found some peculiar conditions causing a
reduction of details over large bright regions (as in ground-glass opacities and in pleural effusions in
bedridden patients) and resulting in oversaturated areas. Here, we have significantly improved the
overall performance of the original approach including the results in those specific cases by developing
PACE2.0. It combines 2D image decomposition, non-local means denoising, gamma correction, and
recursive algorithms to improve image quality. The tool has been evaluated using three metrics:
contrast improvement index, information entropy, and effective measure of enhancement, resulting
in an average increase of 35% in CII, 7.5% in ENT, 95.6% in EME and 13% in BRISQUE against original
radiographies. Additionally, the enhanced images were fed to a pre-trained DenseNet-121 model for
transfer learning, resulting in an increase in classification accuracy from 80 to 94% and recall from
89 to 97%, respectively. These improvements led to a potential enhancement of the interpretability
of lesion detection in CXRs. PACE2.0 has the potential to become a valuable tool for clinical decision
support and could help healthcare professionals detect pneumonia more accurately.
X-ray imaging might contain artifacts, low contrast, diffractions or intensity inhomogeneities.
Recently, we have developed a procedure named PACE that is able to improve chest X-ray (CXR)
images including the enforcement of clinical evaluation of pneumonia originated by COVID-19. At
the clinical benchmark state of this tool, there have been found some peculiar conditions causing a
reduction of details over large bright regions (as in ground-glass opacities and in pleural effusions in
bedridden patients) and resulting in oversaturated areas. Here, we have significantly improved the
overall performance of the original approach including the results in those specific cases by developing
PACE2.0. It combines 2D image decomposition, non-local means denoising, gamma correction, and
recursive algorithms to improve image quality. The tool has been evaluated using three metrics:
contrast improvement index, information entropy, and effective measure of enhancement, resulting
in an average increase of 35% in CII, 7.5% in ENT, 95.6% in EME and 13% in BRISQUE against original
radiographies. Additionally, the enhanced images were fed to a pre-trained DenseNet-121 model for
transfer learning, resulting in an increase in classification accuracy from 80 to 94% and recall from
89 to 97%, respectively. These improvements led to a potential enhancement of the interpretability
of lesion detection in CXRs. PACE2.0 has the potential to become a valuable tool for clinical decision
support and could help healthcare professionals detect pneumonia more accurately.