Tuccimei, Paola
Preferred name
Tuccimei, Paola
Main Affiliation
ORCID
The search returned 8 results
Now showing 1 - 8 of 8
- Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: Open Access , Using a multi-method approach based on soil radon deficit, resistivity, and induced polarization measurements to monitor non-aqueous phase liquid contamination in two study areas in Italy and India
Geochemical and geophysical surveys employing radon deficit, resistivity, and induced polarization (IP) measurements were undertaken on soil contaminated with non-aqueous phase liquids (NAPLs) in two different sites in India and in Italy. Radon deficit, validated through the comparison with average soil radon in reference unpolluted areas, shows the extension of contamination in the upper part of the unsaturated aquifers. In site 1 (Italy), the spill is not recent. A residual film of kerosene covers soil grains, inhibiting their chargeability and reducing electrical resistivity difference with background unpolluted areas. No correlation between the two parameters is observed. Soil volatile organic compounds (VOCs) concentration is not linked with radon deficit, supporting the old age of the spillage. NAPL pollution in sites 2a and 2b (India) is more recent and probably still active, as demonstrated by higher values of electrical resistivity. A good correlation with IP values suggests that NAPL is still distributed as droplets or as a continuous phase in the pores, strengthening the scenario of a fresh spill or leakage. Residual fraction of gasoline in the pore space of sites 2a and 2b is respectively 1.5 and 11.8 kg per cubic meter of terrain. This estimation is referred to the shallower portion of the unsaturated aquifer. Electrical resistivity is still very high indicating that the gasoline has not been strongly degraded yet. Temperature and soil water content influence differently radon deficit in the three areas, reducing soil radon concentration and partly masking the deficit in sites 2a and 2b.135 191 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: Restricted , Using Natural Radon as a Tracer of Gasoline Contamination
Radon concentration in soil gas can be employed to trace the presence of gasoline contamination because it is very soluble in hydrocarbons. Radon available in the soil pores accumulates in the contaminated volume, producing a local deficit at shallow depth that can be easily mapped. The suitability of this method is here checked by field simulation of a gasoline spill and by laboratory experiments where known amounts of a volcanic tuff contaminated with increasing gasoline show proportional drops of radon exhalation rates.65 2 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: Restricted , Correcting for H2O interference using a RAD7 electrostatic collection-based silicon detector
The effect of water molecules on the electrostatic collection of 218Po ions onto the surface of silicon detectors (neutralization) is evaluated through the comparison with a scintillation cell (ZnS), not affected by air humidity. A radon monitor (RAD7, Durridge Company) was connected to a stainless steel radon chamber, equipped with the scintillation cell. Radon gas, extracted from an acidified RaCl2 source, was injected into the chamber and the amount of water molecules in the system was alternatively lowered or increased (from 0.00075 to 0.014 g of water in RAD7) by connecting the chamber to a desiccant or to a bubbling water bottle. The relative efficiency of the silicon detector with respect to the scintillation cell decreases with the growth of water molecules inside RAD7. This dependence, with a fixed i) electrostatic chamber geometry and ii) nominal high voltage, diverges during the humidification or the drying phase because it is in turn influenced by the length of interaction of polonium atoms with water molecules, which impacts on the size of 218Po clusters and thus on the neutralization process. For water contents higher that 0.01 g in RAD7, this effect is greatly enhanced. Temperature in the investigated range (18.5-35.6 °C) does not affect the efficiency of electrostatic collection-based silicon detectors. Based on these experiments, admitting a certain error on the efficiency (from 1.8 to 7.5%, depending on the water content), proper corrections were developed to adjust soil radon readings, when a desiccant is removed. This operation is necessary if recent Non-Aqueous Phase Liquids (NAPLs) leakage has occurred in the subsoil to avoid the sorption and possible later release of radon by Drierite, with related partition between the solid and liquid phases (water and NAPL).102 485 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: Restricted , Our PET project: an unlimited supply of big and small water sample vials for the assay of radon in water
RAD7 and BigBottle system has been developed, using large glass bottles, but these are fragile and awkward to carry around. In searching for a better solution, we tested polyethylene terephthalate (PET) bottles for water samples storage to estimate radon loss over time. Two sets of experiments with 0.355 and 1.75 L bottles demonstrated that PET is a suitable material for storage. If correction for 226Ra content in water is applied, we can also calculate the rate of radon loss (0.03 ± 0.08 % day-1).91 1 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: Restricted , Laboratory simulation of recent NAPL spills to investigate radon partition among NAPL vapours and soil air
Soil radon is employed to trace residual NAPL (Non-Aqueous Phase Liquid) contamination because it is very soluble in these substances and is strongly depleted over polluted volumes of the subsoil. The solubility of radon into NAPL vapors, generally poorly considered, is investigated here, either as growth of radon exhalation from a material contaminated with increasing volumes of kerosene, or as radon partition between liquid kerosene, water and total air, considered ad the sum of kerosene vapors plus air.121 2 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: Restricted , Soil radon survey to assess NAPL contamination from an ancient spill. Do kerosene vapors affect radon partition ?
A soil radon-deficit survey was carried out in a site polluted with kerosene (Rome, Italy) in winter 2016 to assess the contamination due to the NAPL residual component in the vadose zone and to investigate the role of the vapor plume. Radon is indeed more soluble in the residual NAPL than in air or water, but laboratory experiments demonstrated that it is also preferentially partitioned in the NAPL vapors that transport it and may influence soil radon distribution patterns. Specific experimental configurations were designed and applied to a 31-station grid to test this hypothesis; two RAD7 radon monitors were placed in-series and connected to the top of a hollow probe driven up to 80-cm depth; the first instrument was directly attached to the probe and received humid soil gas, which was counted and then conveyed to the second monitor through a desiccant (drierite) cylinder capturing moisture and eventually the NAPL volatile component plus the radon dissolved in vapors. The values from the two instruments were cross-calibrated through specifically designed laboratory experiments and compared. The results are in agreement within the error range, so the presence of significant NAPL vapors, eventually absorbed by drierite, was ruled out. This is in agreement with low concentrations of soil VOCs. Accordingly, the radon-deficit is ascribed to the residual NAPL in the soil pores, as shown very well also by the obtained maps. Preferential areas of radon-deficit were recognised, as in previous surveys. An average estimate of 21 L (17 Kg) of residual NAPL per cubic meter of terrain is provided on the basis of original calculations, developed from published equations. A comparison with direct determination of total hydrocarbon concentration (23 kg per cubic meter of terrain) is provided.141 1 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: Restricted , Evaluating radon loss from water during storage in standard PET, bio-based PET, and PLA bottles
Polyethylene terephthalate (PET) and polylactic acid (PLA) bottles were tested to evaluate radon loss from water during 15 days of storage. PET bottles (lower surface/volume-ratio vials) lost 0.4e7.1% of initial radon, whereas PLA bottles lost 3.7% of it. PET bottles with volume of 0.5 L, lower surface/weight ratio, and hence higher thickness display proportionally reduced radon loss. Corrections for dissolved radium are needed during analyses. Formulas for calculating degassing efficiency and water interference on electrostatic collections are developed.93 235 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: Open Access , Calibration of Big Bottle RAD H2O set-up for radon in water using HDPE bottles
Glass bottles are generally employed for water sampling because glass is impervious to radon and is not lost during sample storage. On the other hand, glass is fragile and may break, so 1 L High Density PolyEthylene (HDPE) bottles (Thermo Scientific Nalgene) are tested in place of glass vessels employing Big Bottle RAD H2O device (Durridge Company) coupled with RAD7 monitor. The purpose of this calibration is to quantify radon loss during storage in HDPE bottles, evaluate possible radon uptake by known volume of desiccant (Drierite, granular CaSO4) and quantify radon interaction with the rubber and plastic parts of the experimental circuit. These processes have been separately investigated, performing proper experiments for the assessment of their influence on resulting radon data using seven series of solutions at known activity concentrations in the range from 27 to 194 Bq/L. Percent radon loss during storage in 1 L HDPE bottles has been estimated at 0.0045 min-1. Radon absorption by desiccant, expressed as ‘equivalent’ volume of Drierite is 0.673 ± 0.092 L and is somehow independent, within errors, from i) the amount of water already absorbed in Drierite, ii) a recirculation time greater than 30 min and iii) radon concentrations. Radon absorption/desorption from rubber and plastic parts of the experimental device has been assessed as a function of concentration gradient between the inner volume of the circuit and the pores of polymer's. A final algorithm accounting for the above described physical processes has been developed for long runs (2-3 h). A simplified calculation method for short measurements (30 min) is also provided.85 278
