De Simone, Gabriele
Preferred name
De Simone, Gabriele
Main Affiliation
15 results
Filters
Settings
The search returned 15 results
Now showing 1 - 10 of 15
- Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: Restricted , Using Natural Radon as a Tracer of Gasoline Contamination
Radon concentration in soil gas can be employed to trace the presence of gasoline contamination because it is very soluble in hydrocarbons. Radon available in the soil pores accumulates in the contaminated volume, producing a local deficit at shallow depth that can be easily mapped. The suitability of this method is here checked by field simulation of a gasoline spill and by laboratory experiments where known amounts of a volcanic tuff contaminated with increasing gasoline show proportional drops of radon exhalation rates.64 2 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: Open Access , Calibration of Big Bottle RAD H2O set-up for radon in water using HDPE bottles
Glass bottles are generally employed for water sampling because glass is impervious to radon and is not lost during sample storage. On the other hand, glass is fragile and may break, so 1 L High Density PolyEthylene (HDPE) bottles (Thermo Scientific Nalgene) are tested in place of glass vessels employing Big Bottle RAD H2O device (Durridge Company) coupled with RAD7 monitor. The purpose of this calibration is to quantify radon loss during storage in HDPE bottles, evaluate possible radon uptake by known volume of desiccant (Drierite, granular CaSO4) and quantify radon interaction with the rubber and plastic parts of the experimental circuit. These processes have been separately investigated, performing proper experiments for the assessment of their influence on resulting radon data using seven series of solutions at known activity concentrations in the range from 27 to 194 Bq/L. Percent radon loss during storage in 1 L HDPE bottles has been estimated at 0.0045 min-1. Radon absorption by desiccant, expressed as ‘equivalent’ volume of Drierite is 0.673 ± 0.092 L and is somehow independent, within errors, from i) the amount of water already absorbed in Drierite, ii) a recirculation time greater than 30 min and iii) radon concentrations. Radon absorption/desorption from rubber and plastic parts of the experimental device has been assessed as a function of concentration gradient between the inner volume of the circuit and the pores of polymer's. A final algorithm accounting for the above described physical processes has been developed for long runs (2-3 h). A simplified calculation method for short measurements (30 min) is also provided.85 268 - Some of the metrics are blocked by yourconsent settings
Item type:Product, Access status: Open Access , 115 208 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: Restricted , Our PET project: an unlimited supply of big and small water sample vials for the assay of radon in water
RAD7 and BigBottle system has been developed, using large glass bottles, but these are fragile and awkward to carry around. In searching for a better solution, we tested polyethylene terephthalate (PET) bottles for water samples storage to estimate radon loss over time. Two sets of experiments with 0.355 and 1.75 L bottles demonstrated that PET is a suitable material for storage. If correction for 226Ra content in water is applied, we can also calculate the rate of radon loss (0.03 ± 0.08 % day-1).90 1 - Some of the metrics are blocked by yourconsent settings
Item type:Product, Access status: Open Access , 84 84 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: Open Access , Continuous monitoring of CO2 and H2S air concentration and soil CO2 flux survey for gas hazard assessment at Tor Caldara nature reserve (Anzio, Italy).
Tor Caldara natural reserve hosts the southernmost discharge of endogenous gas of Colli Albani volcano (mostly CO2 with a relevant H2S content up to 6.3 vol.%). Gas discharges in zones where past sulfur mining removed the impervious surficial cover (e.g. Miniera Grande and Miniera Piccola) and along tectonic fissures. A structural study of the reserve has shown the presence of two zones with different characteristics: prevailing directions NS and N30° in the northern zone; EW and N60° in the southern one. In MarchJuly 2012 a geochemical study was carried out, including a soil CO2 flux survey and continuous monitoring (from 2 to 11 days) of air concentration of CO2 and H2S in 12 sites of the reserve. Environmental parameters were also monitored. Total diffuse soil flux of endogenous CO2 was estimated to 17.48 ton*day1 from 1,259 measurements over a 0.47 km2 surface, with 6.56 ton*day1 only from Miniera Grande. This is the second highest value of soil CO2 flux at Miniera Grande, after that of 2005 (9.25 ton*day1) and is significantly higher than in 2009 (1.20 ton*day1). As both the 2005 and 2012 surveys were made shortly after earthquakes with epicentres near to Tor Caldara (max ML= 4.7 in 2005 and 3.5 in 2012), data confirm that soil CO2 flux increases during earthquakes because of seismic rock microfracturing and soil shaking. Hazardous air concentrations have been found only for H2S, up to immediately lethal values (5651,124 ppm) and with potentially lethal values (≥ 250 ppm) long persisting (up to 12h27’) in several no wind nights. Instead, the CO2 air concentration remained always well below dangerous levels (maximum recorded value = 2.1 vol.%). The most hazardous gas releasing sites were found in Miniera Grande and in a small pond NE of Miniera Piccola, where the carcasses of mammals and other small animals are frequently found. The killer gas is H2S, and the dangerous sites should be appropriately fenced to prevent access to people and animals.690 197 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: Restricted , Correcting for H2O interference using a RAD7 electrostatic collection-based silicon detector
The effect of water molecules on the electrostatic collection of 218Po ions onto the surface of silicon detectors (neutralization) is evaluated through the comparison with a scintillation cell (ZnS), not affected by air humidity. A radon monitor (RAD7, Durridge Company) was connected to a stainless steel radon chamber, equipped with the scintillation cell. Radon gas, extracted from an acidified RaCl2 source, was injected into the chamber and the amount of water molecules in the system was alternatively lowered or increased (from 0.00075 to 0.014 g of water in RAD7) by connecting the chamber to a desiccant or to a bubbling water bottle. The relative efficiency of the silicon detector with respect to the scintillation cell decreases with the growth of water molecules inside RAD7. This dependence, with a fixed i) electrostatic chamber geometry and ii) nominal high voltage, diverges during the humidification or the drying phase because it is in turn influenced by the length of interaction of polonium atoms with water molecules, which impacts on the size of 218Po clusters and thus on the neutralization process. For water contents higher that 0.01 g in RAD7, this effect is greatly enhanced. Temperature in the investigated range (18.5-35.6 °C) does not affect the efficiency of electrostatic collection-based silicon detectors. Based on these experiments, admitting a certain error on the efficiency (from 1.8 to 7.5%, depending on the water content), proper corrections were developed to adjust soil radon readings, when a desiccant is removed. This operation is necessary if recent Non-Aqueous Phase Liquids (NAPLs) leakage has occurred in the subsoil to avoid the sorption and possible later release of radon by Drierite, with related partition between the solid and liquid phases (water and NAPL).102 472 - Some of the metrics are blocked by yourconsent settings
Item type:Product, Access status: Open Access , 753 1605 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: Open Access , Health impact of natural gas emission at Cava dei Selci residential zone (metropolitan city of Rome, Italy)
Natural gas hazard was assessed at Cava dei Selci, a residential neighbourhood of Marino (Rome) by a joint study of gas emissions and related health problems. Here a densely urbanized zone with 4000 residents surrounds a dangerous natural gas discharge where, along the years, dozens of animals were killed by the gas. Gas originates from Colli Albani volcano and consists mostly of CO2 with ~1 vol.% of H2S. In recent years, several gas-related accidents occurred in the urbanized zone (gas blowouts and road collapses). Some houses were evacuated because of hazardous indoor air gas concentration. Gas hazard was assessed by soil CO2 flux and concentration surveys and indoor and outdoor air CO2 and H2S concentration measurements. Open fields and house gardens release a high quantity of CO2 (32.23 tonnes*day-1). Inside most houses, CO2 air concentration exceeds 0.1 vol.%, the acceptable long-term exposure range. In several houses both CO2 and H2S exceed the IDLH level (Immediately Dangerous to Life and Health). An epidemiological cohort study was carried out on the residents of two Cava dei Selci zones with high (ZoneA) and medium (ZoneB) gas hazard exposure, using the rest of Marino as reference zone. We found excess mortality and Emergency Room Visits (ERV) related to high exposure to CO2 and H2S; in particular , an increased risk of mortality and ERV for diseases of central nervous system (HR 1.57, 95% CI 0.76-3.25 and HR 5.82, 95% CI 1.27-26.56 respectively) was found among men living in Zone A.501 120 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: Open Access , Using a multi-method approach based on soil radon deficit, resistivity, and induced polarization measurements to monitor non-aqueous phase liquid contamination in two study areas in Italy and India
Geochemical and geophysical surveys employing radon deficit, resistivity, and induced polarization (IP) measurements were undertaken on soil contaminated with non-aqueous phase liquids (NAPLs) in two different sites in India and in Italy. Radon deficit, validated through the comparison with average soil radon in reference unpolluted areas, shows the extension of contamination in the upper part of the unsaturated aquifers. In site 1 (Italy), the spill is not recent. A residual film of kerosene covers soil grains, inhibiting their chargeability and reducing electrical resistivity difference with background unpolluted areas. No correlation between the two parameters is observed. Soil volatile organic compounds (VOCs) concentration is not linked with radon deficit, supporting the old age of the spillage. NAPL pollution in sites 2a and 2b (India) is more recent and probably still active, as demonstrated by higher values of electrical resistivity. A good correlation with IP values suggests that NAPL is still distributed as droplets or as a continuous phase in the pores, strengthening the scenario of a fresh spill or leakage. Residual fraction of gasoline in the pore space of sites 2a and 2b is respectively 1.5 and 11.8 kg per cubic meter of terrain. This estimation is referred to the shallower portion of the unsaturated aquifer. Electrical resistivity is still very high indicating that the gasoline has not been strongly degraded yet. Temperature and soil water content influence differently radon deficit in the three areas, reducing soil radon concentration and partly masking the deficit in sites 2a and 2b.133 187
