Varnam, Matthew
Preferred name
Varnam, Matthew
ORCID
The search returned 7 results
Now showing 1 - 7 of 7
- Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: Open Access , TROPOMI enables high resolution SO2 flux observations from Mt. Etna, Italy, and beyond
(2019-01-30); ; ; ; The newly launched imaging spectrometer TROPOMI onboard the Sentinel-5 Precursor satellite provides atmospheric column measurements of sulfur dioxide (SO2) and other gases with a pixel resolution of 3.5 × 7 km2. This permits mapping emission plumes from a vast number of natural and anthropogenic emitters with unprecedented sensitivity, revealing sources which were previously undetectable from space. Novel analysis using back-trajectory modelling of satellite-based SO2 columns allows calculation of SO2 flux time series, which would be of great utility and scientific interest if applied globally. Volcanic SO2 emission time series reflect magma dynamics and are used for risk assessment and calculation of the global volcanic CO2 gas flux. TROPOMI data make this flux time series reconstruction approach possible with unprecedented spatiotemporal resolution, but these new data must be tested and validated against ground-based observations. Mt. Etna (Italy) emits SO2 with fluxes ranging typically between 500 and 5000 t/day, measured automatically by the largest network of scanning UV spectrometers in the world, providing the ideal test-bed for this validation. A comparison of three SO2 flux datasets, TROPOMI (one month), ground-network (one month), and ground-traverse (two days) shows acceptable to excellent agreement for most days. The result demonstrates that reliable, nearly real-time, high temporal resolution SO2 flux time series from TROPOMI measurements are possible for Etna and, by extension, other volcanic and anthropogenic sources globally. This suggests that global automated real-time measurements of large numbers of degassing volcanoes world-wide are now possible, revolutionizing the quantity and quality of magmatic degassing data available and insights into volcanic processes to the volcanological community.347 142 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: Open Access , Ground-Based Remote Sensing of Volcanic CO2 Fluxes at Solfatara (Italy)—Direct Versus Inverse Bayesian Retrieval
CO2 is the second most abundant volatile species of degassing magma. CO2 fluxes carry information of incredible value, such as periods of volcanic unrest. Ground-based laser remote sensing is a powerful technique to measure CO2 fluxes in a spatially integrated manner, quickly and from a safe distance, but it needs accurate knowledge of the plume speed. The latter is often difficult to estimate, particularly for complex topographies. So, a supplementary or even alternative way of retrieving fluxes would be beneficial. Here, we assess Bayesian inversion as a potential technique for the case of the volcanic crater of Solfatara (Italy), a complex terrain hosting two major CO2 degassing fumarolic vents close to a steep slope. Direct integration of remotely sensed CO2 concentrations of these vents using plume speed derived from optical flow analysis yielded a flux of 717 121 t day1, in agreement with independent measurements. The flux from Bayesian inversion based on a simple Gaussian plume model was in excellent agreement under certain conditions. In conclusion, Bayesian inversion is a promising retrieval tool for CO2 fluxes, especially in situations where plume speed estimation methods fail, e.g., optical flow for transparent plumes. The results have implications beyond volcanology, including ground-based remote sensing of greenhouse gases and verification of satellite soundings.229 173 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: Open Access , Quantification of ash sedimentation dynamics through depolarisation imaging with AshCam
(2018-10-24); ; ; ; Even modest ash-rich volcanic eruptions can severely impact a range of human activities, especially air travel. The dispersal of ash in these eruptions depends critically on aggregation and sedimentation processes - however these are difficult to quantify in volcanic plumes. Here, we image ash dynamics from mild explosive activity at Santiaguito Volcano, Guatemala, by measuring the depolarisation of scattered sunlight by non-spherical ash particles, allowing the dynamics of diffuse ash plumes to be investigated with high temporal resolution (>1 Hz). We measure the ash settling velocity downwind from the main plume, and compare it directly with ground sampled ash particles, finding good agreement with a sedimentation model based on particle size. Our new, cost-effective technique leverages existing technology, opening a new frontier of integrated ash visualisation and ground collection studies which could test models of ash coagulation and sedimentation, leading to improved ash dispersion forecasts. This will provide risk managers with improved data quality on ash location, reducing the economic and societal impacts of future ash-rich eruptions.451 93 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: Open Access , Quantification of gas, ash, and sulphate aerosols in volcanic plumes from open path Fourier transform infrared (OP-FTIR) emission measurements at Stromboli volcano, Italy
Field-portable Open Path Fourier Transform Infrared (OP-FTIR) spectrometers can be used to remotely measure the composition of volcanic plumes using absorption spectroscopy, providing invaluable data on total gas emissions. Quantifying the temporal evolution of gas compositions during an eruption helps develop models of volcanic processes and aids in eruption forecasting. Absorption measurements require a viewing geometry which aligns infrared source, plume, and instrument, which can be challenging. Here, we present a fast retrieval algorithm to estimate quantities of gas, ash and sulphate aerosols from thermal emission OP-FTIR measurements, and the results from two pilot campaigns on Stromboli volcano in Italy in 2019 and 2021. We validate the method by comparing time series of SO2 slant column densities retrieved using our method with those obtained from a conventional UV spectrometer, demonstrating that the two methods generally agree to within a factor of 2. The algorithm correctly identifies ash-rich plumes and gas bursts associated with explosions and quantifies the mass column densities and particle sizes of ash and sulphate aerosols (SA) in the plume. We compare the ash sizes retrieved using our method with the particle size distribution (PSD) of an ash sample collected during the period of measurements in 2019 by flying a Remotely Piloted Aircraft System into the path of a drifting ash plume and find that both modes of the bimodal PSD (a fine fraction with diameter around 5–10 μm and a coarse fraction around 65 μm) are identified within our datasets at different times. We measure a decrease in the retrieved ash particle size with distance downwind, consistent with settling of larger particles, which we also observed visually. We measure a decrease in the SO2/SA ratio as the plume travels downwind, coupled with an increase in measured SA particle size (range 2–6 μm), suggesting rapid hygroscopic particle growth and/or SO2 oxidation. We propose that infrared emission spectroscopy can be used to examine physical and chemical changes during plume transport and opens the possibility of remote night-time monitoring of volcanic plume emissions. These ground-based analyses may also aid the refinement of satellite-based aerosol retrievals.28 110 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: Open Access , Quantifying Light Dilution in Ultraviolet Spectroscopic Measurements of Volcanic SO2 Using Dual-Band Modeling
High precision and accuracy in volcanic SO2 emission rate quantification is critical for eruption forecasting and, in combination with in-plume gas ratios, quantifying global volcanic emission inventories. Light dilution, where scattering of ultraviolet light dilutes plume SO2 absorbance signals, has been recognized for more than 50 years, but is still not routinely corrected for during gas flux quantification. Here we use modeling and empirical observations from Masaya volcano, Nicaragua, to show that light dilution produces: i) underestimates in SO2 that can reach a factor of 5 and, at low column densities, cause little impact on standard retrieval fit quality, even for heavily diluted spectra; ii) retrieved SO2 amounts that are capped by a maximum value regardless of the true amount of SO2, with this maximum amount being reduced as light dilution increases. Global volcanic volatile emission rates may therefore be significantly underestimated. An easily implementable dual-waveband analysis provides a means to detect, and in clear sky conditions, correct dilution effects directly from the spectra, opening a path to more accurate SO2 quantifications.225 388 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: Open Access , Two Independent Light Dilution Corrections for the SO2 Camera Retrieve Comparable Emission Rates at Masaya Volcano, Nicaragua
SO2 cameras are able to measure rapid changes in volcanic emission rate but require accurate calibrations and corrections to convert optical depth images into slant column densities. We conducted a test at Masaya volcano of two SO2 camera calibration approaches, calibration cells and co-located spectrometer, and corrected both calibrations for light dilution, a process caused by light scattering between the plume and camera. We demonstrate an advancement on the image-based correction that allows the retrieval of the scattering efficiency across a 2D area of an SO2 camera image. When appropriately corrected for the dilution, we show that our two calibration approaches produce final calculated emission rates that agree with simultaneously measured traverse flux data and each other but highlight that the observed distribution of gas within the image is different. We demonstrate that traverses and SO2 camera techniques, when used together, generate better plume speed estimates for traverses and improved knowledge of wind direction for the camera, producing more reliable emission rates. We suggest combining traverses and the SO2 camera should be adopted where possible.200 96 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: Open Access , iFit: A simple method for measuring volcanic SO2 without a measured Fraunhofer reference spectrum
Accurate quantification of the emission rate of sulphur dioxide (SO 2 ) from volcanoes provides both insights into magmatic processes and a powerful monitoring tool for hazard mitigation. The primary method for measuring magmatic SO 2 is Differential Optical Absorption Spectroscopy (DOAS) of UV scattered sunlight spectra, in which a reference spectrum taken outside the plume is used to quantify the SO2 slant column density inside the plume. This can lead to problems if the reference spectrum is contaminated with SO2 as this will result in a systematic underestimation of the retrieved SO2 slant column density, and therefore emission rate. We present a new analysis method, named ―iFit‖, which retrieves the SO 2 slant column density from UV spectra by directly fitting the measured intensity spectrum at high spectral resolution (0.01 nm) using a literature solar reference spectrum and measured instrument characteristics. This eliminates the requirement for a measured reference spectrum, providing a ―point and shoot‖ method for quantifying SO 2 slant column densities. We show that iFit retrieves correct SO2 slant column densities in a series of test cases, finding agreement with existing methods. We propose that iFit is suitable for both traverse measurements and permanent scanning stations, and could be integrated into volcano monitoring networks at observatories. Finally, we provide an open source software implementation of iFit with a user friendly graphical interface to allow users to easily utilise iFit.254 120
