iFit: A simple method for measuring volcanic SO2 without a measured Fraunhofer reference spectrum
Author(s)
Language
English
Obiettivo Specifico
5V. Processi eruttivi e post-eruttivi
Status
Published
JCR Journal
JCR Journal
Peer review journal
Yes
Issue/vol(year)
/402 (2020)
Publisher
Elsevier
Pages (printed)
107000
Date Issued
2020
Subjects
Abstract
Accurate quantification of the emission rate of sulphur dioxide (SO 2 ) from volcanoes provides both insights into magmatic processes and a powerful monitoring tool for hazard mitigation. The primary method for measuring magmatic SO 2 is Differential Optical Absorption Spectroscopy (DOAS) of UV scattered sunlight spectra, in which a reference spectrum taken outside the plume is used to quantify the SO2 slant column density inside the plume. This can lead to problems if the reference spectrum is contaminated with SO2 as this will result in a systematic underestimation of
the retrieved SO2 slant column density, and therefore emission rate. We present a new analysis method, named ―iFit‖, which retrieves the SO 2 slant column density from UV spectra by directly fitting the measured intensity spectrum at high spectral resolution (0.01 nm) using a literature solar reference spectrum and measured instrument characteristics. This eliminates the requirement for a measured reference spectrum, providing a ―point and shoot‖ method for quantifying SO 2 slant column densities. We show that iFit retrieves correct SO2 slant column densities in a series of test
cases, finding agreement with existing methods. We propose that iFit is suitable for both traverse measurements and permanent scanning stations, and could be integrated into volcano monitoring networks at observatories. Finally, we provide an open source software implementation of iFit with a user friendly graphical interface to allow users to easily utilise iFit.
the retrieved SO2 slant column density, and therefore emission rate. We present a new analysis method, named ―iFit‖, which retrieves the SO 2 slant column density from UV spectra by directly fitting the measured intensity spectrum at high spectral resolution (0.01 nm) using a literature solar reference spectrum and measured instrument characteristics. This eliminates the requirement for a measured reference spectrum, providing a ―point and shoot‖ method for quantifying SO 2 slant column densities. We show that iFit retrieves correct SO2 slant column densities in a series of test
cases, finding agreement with existing methods. We propose that iFit is suitable for both traverse measurements and permanent scanning stations, and could be integrated into volcano monitoring networks at observatories. Finally, we provide an open source software implementation of iFit with a user friendly graphical interface to allow users to easily utilise iFit.
Type
article
File(s)![]()
![]()
Name
Esse et al., 2020.pdf
Description
ms
Size
2.86 MB
Format
Adobe PDF
Checksum (MD5)
The MD5 message-digest algorithm can be used to verify the integrity of the file that you have uploaded. You can calculate its value locally via tools that are generally available in each operative system like md5sum
cb1a87b2d6e9249f2d25903001062c1f
Name
iFit_JVGR_Revision_2.pdf
Size
2.43 MB
Format
Adobe PDF
Checksum (MD5)
The MD5 message-digest algorithm can be used to verify the integrity of the file that you have uploaded. You can calculate its value locally via tools that are generally available in each operative system like md5sum
6b10aac5abf2a44ac39e9d0cb853b9ef
