Skip to main content
The search returned 50 results
Now showing 1 - 10 of 50
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: Open Access ,

    Earthquake Early Warning System for Virgo: a design study

    The Virgo interferometer was able to reach its design sensitivity thanks to the performance of the seismic superattenuators. However, the ground shaking due to earthquakes both from regional and teleseismic distances can significantly affect the instrument duty cycle, especially during extended observational runs like the imminent O3.A strong event in proximity to the site could even threaten the delicate fused-silica suspensions.A fast, reliable Earthquake Early Warning system (EEWS) should issue an alert of incoming ground shaking leaving enough time to take appropriate counteractions to limit uncontrolled and unwanted oscillations of test masses. First we analyse the effects of past and present earthquakes at Virgo site with the goal to assess the relevant parameters (like distance, magnitude, azimuth) of the events able to cause significant shaking.This is accomplished using data recorded during the O2 run from seismometers located in the Virgo buildings integrated by data from italian seismic network from INGV.Then we present some ideas about the implementation of an EEWS and its requirements in term of new technologies to be developed within the framework of INGV and Ego Virgo collaboration. The aim is to define the most appropriate EEWS schema in order to maximize both safety and duty cycle of the interferometers for the case of local, regional and teleseismic earthquakes.
      226  317
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: Restricted ,

    Arrival angles of teleseismic fundamental mode Rayleigh waves across the the AlpArray

    The dense AlpArray network allows studying seismic wave propagation with high spatial resolution. Here we introduce an array approach to measure arrival angles of teleseismic Rayleigh waves. The approach combines the advantages of phase correlation as in the two-station method with array beamforming to obtain the phase-velocity vector. 20 earthquakes from the first two years of the AlpArray project are selected, and spatial patterns of arrival-angle deviations across the AlpArray are shown in maps, depending on period and earthquake location. The cause of these intriguing spatial patterns is discussed. A simple wave-propagation modelling example using an isolated anomaly and a Gaussian beam solution suggests that much of the complexity can be explained as a result of wave interference after passing a structural anomaly along the wave paths. This indicates that arrival-angle information constitutes useful additional information on the Earth structure, beyond what is currently used in inversions.
      3356  7
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: Open Access ,

    The Pollino seismic sequence/swarm

    In the years between 2010 and 2015 in the Apennines-Calabrian arc boundary, in the Pollino massif, a long seismic sequence took place. The area is subject to Northeast- Southwest extension, which results in a complex system of normal faults striking Northwest-Southeast, nearly parallel to the Apenninic mountain range. The seismic sequence includes more than 6000 earthquakes in the Pollino region, the maximum magnitude recorded is Ml=5.0 and it happened in October 25th 2012 after about two years of ongoing activity; the peculiar temporal evolution of the seismic sequence allows us to catalogue it as a swarm. Here we describe the main seismological characteristics of this seismic sequence and characterise the fracture field of the region. We analyse thousands of seismograms, deriving accurate locations crust velocity model and anisotropic parameters in the crust. These parameters yield clues and insights that may help understanding the physical mechanisms behind the seismic swarm. Since the late 60s-early 70s era seismologists started developing theories that included variations of the elastic properties of the Earth crust and the state of stress and its evolution prior to the occurrence of a large earthquake. Among the others the theory of the dilatancy: when a rock is subject to stress, the rock grains are shifted generating microcracks, thus the rock itself increases its volume. Inside the fractured rock, fluid saturation and pore pressure play an important role in earthquake nucleation, by modulating the effective stress. Thus, measuring the variations of wave speed and of anisotropic parameter in time can be highly informative on how the stress leading to a major fault failure builds up. We systematically look at seismic-wave propagation properties to possibly reveal short-term variations in the elastic properties of the Earth crust. In active fault areas, tectonic stress variation influences fracture field orientation and fluid migration processes, whose evolution over time can be monitored through the measurement of the anisotropic parameters. We analysed waveforms recorded at permanent and temporary stations hold by the Istituto Nazionale di Geofisica e Vulcanologia.
      199  122
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: Open Access ,

    Emergenza sismica in Molise. Report preliminare del Gruppo Operativo SISMIKO.

    Il 16 agosto 2018 alle ore 18:19:04 UTC un terremoto di magnitudo ML 5.2 (Mw 5.1) è stato ben risentito in un’ampia area che comprende molte regioni del Centro Sud Italia. I sismologi in turno presso la sala di monitoraggio e sorveglianza sismica dell’Istituto Nazionale di Geofisica e Vulcanologia (INGV) hanno localizzato l’evento in provincia di Campobasso, a 4 km a Sud-Est di Montecilfone e ad una profondità inizialmente calcolata di 9 km. Nella stessa area si era verificato due giorni prima, il 14 agosto alle ore 23.48 italiane un terremoto di Mw 4.6 anch’esso ben risentito (i dettagli dell’evento sono reperibili alla pagina [http://cnt.rm.ingv.it/event/20375681]). A seguito dell’evento di magnitudo Mw 5.1 e della sequenza ad esso associata, come in ogni emergenza di questo tipo, è stato attivato il Gruppo Operativo SISMIKO [Moretti et al., 2012; 2016; Pondrelli et al., 2016] per l’installazione di alcune stazioni sismiche temporanee ad integrazione di quelle permanenti della Rete Sismica Nazionale (RSN [Michelini et al., 2016]) presenti nella regione.
      239  220
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: Open Access ,

    Observation and analyses of shear wave splitting at the Larderello-Travale geothermal field, Italy

    We measured shear wave splitting (SWS) parameters from a large dataset of local microearthquakes recorded at the Larderello-Travale geothermal field (LTGF; Tuscany, Italy). For that geothermal area, seismic anisotropy is distributed in the upper crust following a complex pattern. Although the overall trend reflects the strike of the normal faults dominating the region, measurements at the southern and central part of the LTGF show large (up to 90°) deviations from the dominant polarization direction. This anomalous pattern suggests that besides the extensive dilatancy anisotropy, the fast wave polarization direction is also likely affected by the presence of over-pressurized geothermal fluids, by local rearrangement of the regional stress, and by the presence of non-vertical cracks. We found large differences in normalised delay times between sparse and clustered seismicity. While the average anisotropy percentage is on the order of 1.7%, a significant amount of our measurements exceeds the 4.5%, reaching values as high as 16%. The highest anisotropy percentages are associated with earthquakes located at the center and at the SE margin of the geothermal area, at depths lower than 5 km and in the 5–10 km range, respectively. This latter occurrence may be interpreted in terms of cracks filled with fluids which, given the expected pressure and temperature conditions, are likely in supercritical conditions. Shear-wave splitting thus confirms to be a powerful tool for better constraining location and extent of those deep fractured rock portions possibly hosting supercritical fluids, that represent the next frontier of geothermal exploitation due to their enhanced heat capacity.
      269  84
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: Open Access ,

    Reservoir Structure and Wastewater-Induced Seismicity at the Val d'Agri Oilfield (Italy) Shown by Three-Dimensional Vp and Vp /Vs Local Earthquake Tomography

    Wastewater injection into a high-rate well in the Val d’Agri oilfield, the largest in onshore Europe, has induced swarm microseismicity since the initiation of disposal in 2006. To investigate the reservoir structure and to track seismicity, we performed a high-spatial resolution local earthquake tomography using 1,281 natural and induced earthquakes recorded by local networks. The properties of the carbonate reservoir (rock fracturing, pore fluid pressure) and inherited faults control the occurrence and spatiotemporal distribution of seismicity. A low-Vp, high-Vp/Vs region under the well represents a fluid saturated fault zone ruptured by induced seismicity. High-Vp, high-Vp/Vs bumps match reservoir culminations indicating saturated liquid-bearing zones, whereas a very low Vp, low Vp/Vs anomaly might represent a strongly fractured and depleted zone of the hydrocarbon reservoir characterized by significant fluid withdrawal. The comprehensive picture of the injection-linked seismicity obtained by integrating reservoir-scale tomography, high-precision earthquake locations, and geophysical and injection data suggests that the driving mechanism is the channeling of pore pressure perturbations through a high permeable fault damage zone within the reservoir. The damage zone surrounds a Pliocene reverse fault optimally oriented in the current extensional stress field. The ruptured damage zone measures 2 km along strike and 3 km along dip and is confined between low permeability ductile formations. Injection pressure is the primary parameter controlling seismicity rate. Our study underlines that local earthquake tomography also using wastewater-induced seismicity can give useful insights into the physical mechanism leading to these earthquakes.
      1016  168
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: Open Access ,

    Discovering geothermal supercritical fluids: a new frontier for seismic exploration

    Exploiting supercritical geothermal resources represents a frontier for the next generation of geothermal electrical power plant, as the heat capacity of supercritical fluids (SCF),which directly impacts on energy production, is much higher than that of fluids at subcritical conditions. Reconnaissance and location of intensively permeable and productive horizons at depth is the present limit for the development of SCF geothermal plants. We use, for the first time, teleseismic converted waves (i.e. receiver function) for discovering those horizons in the crust. Thanks to the capability of receiver function to map buried anisotropic materials, the SCF-bearing horizon is seen as the 4km-depth abrupt termination of a shallow, thick, ultra-high (>30%) anisotropic rock volume, in the center of the Larderello geothermal field. The SCF-bearing horizon develops within the granites of the geothermal field, bounding at depth the vapor-filled heavily-fractured rock matrix that hosts the shallow steam-dominated geothermal reservoirs. The sharp termination at depth of the anisotropic behavior of granites, coinciding with a 2 km-thick stripe of seismicity and diffuse fracturing, points out the sudden change in compressibility of the fluid filling the fractures and is a key-evidence of deep fluids that locally traversed the supercritical conditions. The presence of SCF and fracture permeability in nominally ductile granitic rocks open new scenarios for the understanding of magmatic systems and for geothermal exploitation.
      358  137
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: Restricted ,

    Crustal seismic anisotropy beneath Shillong plateau - Assam valley in North East India: Shear-wave splitting analysis using local earthquakes

    We present crustal anisotropy estimates constrained by shear wave splitting (SWS) analysis using local earthquakes in the Shillong plateau and Assam valley area, North East India (NE India) region. Splitting parameters are determined using an automated cross-correlation (CC) method. We located 330 earthquakes recorded by 17 broadband seismic stations during 2001–2014 in the study area. Out of these 330 events, seismograms of 163 events are selected for the SWS analysis. Relatively small average delay times (0.039–0.084 s) indicate existence of moderate crack density in the crust below the study area. It is found that fast polarization directions vary from station to station depending on the regional stress system as well as geological conditions. The spatial pattern of crustal anisotropy in the area is controlled mostly by tectonic movement of the Indian plate towards NE. Presence of several E-W and N-S trending active faults in the area also play an important role on the observed pattern of crustal anisotropy.
      203  3
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: Open Access ,

    Emergenza sismica nel centro Italia. Terzo rapporto del gruppo operativo SISMIKO

    SISMIKO è una task force operativa che prevede il coordinamento a livello nazionale delle Reti Sismiche Mobili di Pronto Intervento dell’Istituto Nazionale di Geofisica e Vulcanologia (INGV) [Moretti et al., 2012; 2016; Pondrelli et al., 2016] e coinvolge le diverse Sezioni INGV che si occupano normalmente del monitoraggio sismico del territorio nazionale. La notte del 24 agosto 2016, a poche ore dal forte terremoto di magnitudo 6.0 che ha interessato il vasto settore del centro Italia, al confine tra l’Umbria, il Lazio, l’Abruzzo e le Marche [Gruppo di Lavoro INGV sul terremoto di Amatrice, 2016a; 2016b], SISMIKO, come gli altri gruppi operativi INGV previsti per la gestione delle emergenze, ovvero EMERGEO, per il rilievo degli effetti geologici cosismici, EMERSITO, per lo studio gli effetti di sito, QUEST per il rilievo macrosismico e IES rivolto alle attività informative per le scuole e la popolazione coinvolta, è stato prontamente convocato per partecipare all’Unità di Crisi INGV e, come previsto nell’ambito della Convenzione vigente fra il Dipartimento di Protezione Civile (DPC) e l’INGV, si è adoperato per l’installazione di stazioni sismiche temporanee ad integrazione della Rete Sismica Nazionale (RSN [Michelini et al., 2016]) presente in area epicentrale [SISMIKO working group, 2016a; Moretti et al., 2016]. La prima geometria della rete sismica temporanea installata da SISMIKO a pochi giorni dall’inizio della sequenza sismica, era costituita da 19 stazioni di cui 14 a 6 componenti (maggiori dettagli in [SISMIKO working group, 2016a; Moretti et al., 2016]). Successivamente, a seguito delle forti scosse che il 26 ottobre e poi il 30 ottobre hanno interessato il settore settentrionale della sequenza, la rete è stata ampliata di circa 25 km verso nord [SISMIKO working group, 2016b] portando a 23 il numero delle stazioni temporanee distribuite in un’area di circa 75 x60 km2. Nei primi giorni del nuovo anno, a causa di avverse condizioni meteo che hanno interessato tutta l’area colpita dal sisma, molte stazioni sismiche, sia permanenti che temporanee, hanno avuto gravi problemi di funzionamento mettendo a dura prova il sistema di monitoraggio della sequenza sismica in atto: numerose sono state le interruzioni della corrente elettrica che hanno influito sulla continuità della trasmissione dei dati, soprattutto nell’area abruzzese. Per diversi giorni è stato considerato imprudente mandare personale in area epicentrale per la manutenzione e il ripristino della strumentazione, considerato che era comunque garantita l’efficienza del servizio di sorveglianza sismica. La mattina del 18 gennaio, 4 nuove scosse di magnitudo superiore a 5.0 sono avvenute nell’estremità meridionale dell’area già attivatasi e quindi, seppur con difficoltà, sono state avviate le procedure per il ripristino del maggior numero di stazioni sismiche possibile. In tale occasione è stata installata una ulteriore stazione nella zona a SW della sequenza, a migliore copertura dell’ultima area colpita, portando a 24 il numero totale di stazioni temporanee installate dal 24 agosto 2016. In queste ultime settimane, il personale del gruppo operativo SISMIKO è stato costantemente impegnato nella cura e nella manutenzione della strumentazione per garantire la continuità dell’acquisizione e della trasmissione dei dati. Alla data di aggiornamento del presente report, è stata decretata, anche in considerazione dell’andamento della sismicità, una rimodulazione della geometria della rete sismica temporanea che avverrà durante la primavera. Tutti i dati acquisiti dalle stazioni temporanee SISMIKO, continuano ad essere disponibili senza alcun vincolo, al pari dei dati della RSN, tramite l’archivio di forme d’onda European Integrated Data Archive (EIDA [Mazza et al., 2012]) e utilizzati per prodotti scientifici in tempo reale (localizzazioni fornite in sala di sorveglianza sismica INGV, calcolo dei Time Domain Moment Tensor, shakeMaps, ecc) e off-line (ri-localizzazioni, ecc).
      277  283
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: Open Access ,

    AlpArray-Italy: Site description and noise characterization

    Within the framework of the European collaborative research initiative AlpArray (http://www.alparray.ethz. ch), the Istituto Nazionale di Geofisica e Vulcanolgia (INGV) deployed overall 20 broad-band seismic stations in Northern Italy and on two islands in the Tyrrhenian Sea (Capraia and Montecristo) during Fall-Winter 2015. The temporary deployment (16 stations) will run for two to three years and 4 INGV National Seismic Network accelerometric sites are now equipped with additional per- manent broad-band sensors. The 16 temporary stations are equipped with REF TEK 130 digitizers and Nanometrics Trillium Compact 120 s sensors, a couple have Nanometrics Trillium 120P sensors and one a Streckeisen STS2. For each site we describe the settings and discuss the noise levels, the site effects and the preliminary sensitivity analysis.
      2639  97