Albanese, Stefano
Preferred name
Albanese, Stefano
ORCID
3 results
Filters
Settings
The search returned 3 results
Now showing 1 - 3 of 3
- Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: Open Access , Multidisciplinary high resolution Geophysical Imaging of Pantano Ripa Rossa Segment of the Irpinia Fault (Southern Italy)
(2024-11-06); ;Ferrara, Giuseppe; ; The Irpinia Fault, also known as the Monte Marzano Fault System, located in the Southern Apennines (Italy), is one of the most seismically active structures in the Mediterranean. It is the source of the 1980, Ms 6.9, multi-segment rupture earthquake that caused significant damage and nearly 3,000 casualties. Paleoseismological surveys indicate that this structure has generated at least four Mw ~ 7 surface-rupturing earthquakes in the past 2 ka. This paper presents a comprehensive, high-resolution geophysical investigation focused on the southernmost fault segment of the Monte Marzano Fault System, i.e., the Pantano-Ripa Rossa Fault, outcropping within the Pantano di San Gregorio Magno intramontane basin. The project, named TEst Site IRpinia fAult (TESIRA), was supported by the University of Napoli Federico II to study the near-surface structure of this intra-basin fault splay that repeatedly ruptured co-seismically in the past thousands of years. Our imaging approach included 2D and 3D electrical and seismic surveys, gravimetry, 3D FullWaver electrical tomography, drone-borne GPR and magnetic surveys, and CO2 soil flux assessment across the surface rupture. This multidisciplinary investigation improved our understanding of the basin shallow structure, providing an image of a rather complex subsurface fault and basin geometry. Seismic data suggest that fault activity at the Pantano segment of MMFS is characterized by a near-surface cumulative displacement greater than previous estimations, calling into question earlier assumptions about the timing of its activation. Despite some challenges with our drone-mounted survey equipment, the integrated dataset provides a comprehensive and reliable image of the subsurface structure. This work demonstrates the utility of developing an integrated approach at high-resolution geophysical imaging and interpretation of fault zones with weak morphological expressions.18 97 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: Open Access , Hierarchical clustering and compositional data analysis for interpreting groundwater hydrogeochemistry: The application to Campi Flegrei volcanic aquifer (south Italy)
Comprehensive hydrogeochemical studies have been conducted in the Campi Flegrei volcanic aquifer since late 20th century due to the volcanic unrest. In the last decade, groundwater samples were grouped based on the dominant anion species (i.e. bicarbonate, sulfate and chloride) to explain the general hydrogeochemical processes. In this article, 44 groundwater samples are collected from Campi Flegrei aquifer to geochemically and spatially capture the main characteristics of the groundwater body. The hierarchical clustering algorithm is then performed on proportion of bicarbonate, sulfate and chloride, and the optimum number of clusters are determined regarding the results of deep hydrogeochemical investigations published in the past. The collected samples are categorized in the following groups: (1) bicarbonate-rich groundwater; (2) chlorine-rich groundwater; (3) sulfate-rich groundwater; and (4) mixed groundwater. The first group (As = 158.2 ± 169 μg/l, electric conductivity = 1,732.1 ± 1,086 μS/cm and temperature = 25.6 ± 8 ◦C) is mainly derived from poor arsenic meteoric water, but there is significant thermal/seawater contribution in the second one (As = 1,457.8 ± 2,210 μg/l, electric conductivity = 20,118.3 ± 11,139 μS/cm and temperature = 37.1 ± 20 ◦C). Interaction of the bicarbonate-rich groundwater and hydrothermal vapors gives rise to the sulfate-rich groundwater (As = 847.2 ± 679 μg/l, electric conductivity = 3,940.0 ± 540 μS/cm and temperature = 82.8 ± 3 ◦C) around Solfatara volcano. The mixed groundwater (As = 451.4 ± 388 μg/l, electric conductivity = 4,482.9 ± 4,027 μS/cm and temperature = 37.1 ± 16 ◦C) is observed where the three main groundwater groups undergo a mixing process, depending on the hydrogeology of the volcanic aquifer. Contrary to the bicarbonate- and sulfate-rich groundwater, the chlorine-rich and mixed groundwater generally occurs at low piezometric levels (approximately <1 m above sea level) near the coastline. The hierarchical cluster analysis provides more information about the volcanic aquifer, particularly when compositional data analysis is applied to study hydrogeochemistry of the homogeneous groundwater groups and to uncover the relationships between variables. Addressing compositional nature of data is recommended in the future studies for developing new tools that help deeper understanding of groundwater evolution in volcanic aquifers and identifying promising precursors of volcanic eruption.534 380 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: Restricted , The first application of compositional data analysis (CoDA) in a multivariate perspective for detection of pollution source in sea sediments: The Pozzuoli Bay (Italy) case study
In the last decades, investigating geochemistry of sea sediments has been challenging in the eastern sector of Pozzuoli Bay, source of the metal(loid)s has been a matter of debate and the proposed origin of potentially toxic elements (PTEs) has been occasionally inconsistent. In this study, compositional data analysis (CoDA) was used because the results are independent of the measurement unit, the selected subgroup of elements and the order of chemicals in the dataset. The robust variant of principal component analysis (PCA) indicated that Hg, Cd, Cu, Pb and Zn were positively correlated with mud and organic matter in the sediments deposited in front of the former industrial site. Concentrations of these metals decrease along the cores and in the distal zone. Nevertheless, Al, As, V, Fe, Cr, Ni and sand form an association along the coast which strengthens with increasing distance from fumaroles in the proximal zone. It suggests that arsenic was mainly originated from the pyroclastic deposits of Campi Flegrei and some of the seepages with hydrothermal component, supported by low contribution of the variables in robust PCA of the sediments from distal zone. Therefore, this pioneering article suggests CoDA as a powerful tool for answering the long-lasting questions over sediment geochemistry in polluted areas.353 3
