Yang, William
Preferred name
Yang, William
4 results
Filters
Settings
The search returned 4 results
Now showing 1 - 4 of 4
- Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: Open Access , PGS1, a new low cost and low power Portable Geo-physical Station “All in One”. Design and test
PGS1 is a new compact portable seismic station, designed at INGV OBS and Earth Lab, that is specifically intended for the deployment of dense arrays of seismographs on-shore. With its low cost, compact design, high data-quality and long battery life, PGS1 is a perfect solution for seismic monitoring networks. PGS1 design is based on a solid polypropylene suitcase, containing a complete data acquisition system, two battery packs and a photovoltaic panel. The new Earth Lab 5s medium-period seismic sensor is included. The whole system meets the IP67 standard requirements both in transport and in acquisition configuration. PGS1 is normally equipped with one battery pack, one more pack can be added inside the suitcase achieving 40 days of battery life. The station is equipped with a photovoltaic panel, useful to extend the deployment length. Inside the suitcase, there are compartments where to store the seismic sensor, the photovoltaic panel and all the cables. Therefore, the station is very easy to transport.216 118 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: Open Access , A study for the selection of a calibration system for seismic sensors
This work sets out to identify a state-of-the-art system to be used for the calibration of seismic sensors. The aim is to acquire such a system within the framework of the PON ARS01 00926 EWAS (an Early Warning System for cultural heritage) project, which seeks to develop new technologies for the protection, conservation and safety of cultural heritage and envisages creating a newly developed seismic monitoring system. This system will exploit the ETL3D/5s-H hybrid sensors, resulting from the integration of a precision accelerometer within the ETL3D/5s velocimeter [Fertitta et al., 2020]. The new calibration system, already acquired and being installed, can be used by the EWAS project partners (including the National Institute of Geophysics and Volcanology and the Kore University of Enna), to calibrate the ETL3D/5s-H sensors, and by external organisations to calibrate or gauge other seismic sensors, thus providing a useful service to the scientific community and supporting industrial activities. This paper presents the method used and the activities undertaken to define the technical specifications of the calibration system. A feasibility study of an electromechanical vibrating table and the testing of two electrodynamic calibration systems were carried out. One of the electrodynamic systems is the CS18P (Calibration System for Seismic Sensors) produced by the German firm SPEKTRA. The CS18P comprises two vibrating tables, one horizontal and one vertical, which, thanks to their fluid-dynamic suspension, eliminate the sliding and rolling friction associated with the movement of the moving part with respect to the fixed part. A hardware and software system monitors and controls the motion in real time, analyses the data and automatically processes a predefined set of measurements. In the light of the technical specifications and experimental results, the CS18P represents the ideal solution for the aims of the EWAS project and also in view of the possible future uses of the calibration system.242 638 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: Open Access , The Urban Seismic Observatory of Catania (Italy): A Real-Time Seismic Monitoring at Urban Scale
(2022-05-27); ; ; ; We describe the first dense real-time urban seismic–accelerometric network in Italy, named OSU-CT, located in the historic center of Catania. The city lies in the region with the greatest danger, vulnerability, and earthquake exposure in the entire Italian territory. OSU-CT was planned and realized within the project called EWAS “an Early WArning System for cultural heritage”, aimed at the rapid assessment of earthquake-induced damage and the testing of an on-site earthquake early warning system. OSU-CT is mainly based on low-cost instrumentation realized ad hoc by using cutting-edge technologies and digital MEMS (micro-electro-mechanical systems) triaxial accelerometers with excellent resolution and low noise. Twenty of the forty scheduled stations have already been set up on the ground floor of significant historic public buildings. In order to assess the performance of an earthquake early warning (EEW) on-site system, we also installed wide-band velocimeters (ETL3D/5s) in three edifices chosen as test sites, which will be instrumented for a structural health monitoring (SHM). In addition to several laboratory and field validation tests on the developed instruments, an effective operational test of OSU-CT was the Mw 4.3 earthquake occurring on 23 December 2021, 16 km west, south-west of Catania. Peak ground accelerations (4.956 gal to 39.360 gal) recorded by the network allowed obtaining a first urban shakemap and determining a reliable distribution of ground motion in the historical center of the city, useful for the vulnerability studies of the historical edifices.363 229 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: Open Access , Debris-flow hazard assessment at the archaeological UNESCO world heritage site of Villa Romana del Casale (Sicily, Italy)
Archaeological sites are extremely vulnerable to the impacts of weather-related events, which may lead to irreparable damages to cultural heritage. Here an assessment of the debris-flow hazard for the UNESCO site of Roman Villa del Casale (Italy) is carried out, through a combination of historical analyses, field surveys, geomorphological and hydrological investigations and two-dimensional hydraulic numerical modelling, all performed at river catchment scale. Historical analyses reveal that the site has been hit by several landslides in the far and recent past. This is presently confirmed by the high level of exposure to the impact of rain-triggered debris-flow events, due to the position of the Villa at a closure section of the related river basin and to the hydro- geomorphological characteristics of the basin itself. By applying the proposed approach, a scenario analysis is carried out. Results allow one to highlight the dynamics of the impact of debris flows, thanks to space and time- dependent maps about deposition areas, water depth and speed values, and to identify the most vulnerable archaeological elements within the study site. The numerical simulations are also used to test the efficiency of the existing hydraulic defense systems and to support the implementation of an early warning system for the site protection. Here, we also synthetize the design of the architecture of the wireless monitoring network, the sensor technology adopted to develop an effective real time environmental monitoring system and management plat-form, to construct a Wireless Sensor Network (WSN) - early warning and reporting system, which can be applied as a prevention measure.39 89
