Perrone, A.
Preferred name
Perrone, A.
Main Affiliation
The search returned 2 results
Now showing 1 - 2 of 2
- Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: Open Access , 2D electrical resistivity tomographies for investigating recent activation landslides in Basilicata Region (Southern Italy)
(2008-02); ; ; ; The results of a geoelectrical survey in the study of recent activation landslides in the Lucanian Apennine chain (Southern Italy) are discussed in this paper. During the last two years, after meteorological conditions which affected Southern Italy and in particular Basilicata Region, many landslides occurred in this area as reactivations of old movements. These reactivations seriously damaged buildings and infrastructure and they threatened the safety of the people living in the area. Taking into account the complexity and danger of the phenomena, some evacuation decrees for a few houses were adopted. In a short time and at low cost, by using the Mobile Laboratory of IMAA for geophysical measurements, active geoelectrical investigations were carried out and data processing performed using innovative techniques for data inversion. The results represent a valid cognitive support to choose the most appropriate technical solution for strengthening of the slopes and an example of best practice for the cooperation between the Civil Protection of Basilicata Region and IMAA-CNR333 1226 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: Open Access , New geological insights and structural control on fluid circulation in La Fossa cone (Vulcano, Aeolian Islands, Italy)
Electric resistivity tomography (ERT), self-potential (SP), soil CO2 flux, and temperature are used to study the inner structure of La Fossa cone (Vulcano, Aeolian Islands). Nine profiles were performed across the cone with a measurement spacing of 20 m. The crater rims of La Fossa cone are underlined by sharp horizontal resistivity contrasts. SP, CO2 flux, and temperature anomalies underline these boundaries which we interpret as structural limits associated to preferential circulation of fluids. The Pietre Cotte crater and Gran Cratere crater enclose the main hydrothermal system, identified at the centre of the edifice on the base of low electrical resistivity values (b20 Ω m) and strong CO2 degassing, SP, and temperature anomalies. In the periphery, the hydrothermal activity is also visible along structural boundaries such as the Punte Nere, Forgia Vecchia, and Palizzi crater rims and at the base of the cone, on the southern side of the edifice, along a fault attributed to the NW main tectonic trend of the island. Inside the Punte Nere crater, the ERT sections show an electrical resistive body that we interpret as an intrusion or a dome. This magmatic body is reconstructed in 3D using the available ERT profiles. Its shape and position, with respect to the Pietre Cotte crater fault, allows replacing this structure in the chronology of the development of the volcano. It corresponds to a late phase of activity of the Punte Nere edifice. Considering the position of the SP, soil CO2 flux, and temperature maxima and the repartition of conductive zones related to hydrothermal circulation with respect to the main structural features, La Fossa cone could be considered as a relevant example of the strong influence of preexisting structures on hydrothermal fluid circulation at the scale of a volcanic edifice.601 1677