Please use this identifier to cite or link to this item: http://hdl.handle.net/2122/14036
Authors: Tescione, Ines* 
Todesco, Micol* 
Giordano, Guido* 
Title: Geothermal fluid circulation in a caldera setting: The Torre Alfina medium enthalpy system (Italy)
Journal: Geothermics 
Series/Report no.: /89 (2021)
Publisher: Elsevier
Issue Date: 2021
DOI: 10.1016/j.geothermics.2020.101947
URL: https://www.sciencedirect.com/science/article/pii/S037565052030239X
Abstract: The Torre Alfina medium enthalpy geothermal field is located about 10 km north of the Bolsena caldera (Italy). The reservoir is a buried structural high consisting of fractured Meso-Cenozoic carbonate sequences and sealed by clayey flysch successions and Pliocene marine clays. We performed TOUGH2 numerical simulations, testing different model designs based on contrasting conceptual models. Results indicate that deep circulation is forced by the geometry of the reservoir and by the applied T and P gradients. We interpret the Torre Alfina field as a "blind" system, mostly recharged by lateral advection of heat and fluids from the Bolsena caldera deep high-enthalpy system, through the permeable caldera faults.
Appears in Collections:Article published / in press

Files in This Item:
File Description SizeFormat Existing users please Login
Tescione et al2021.pdf12.09 MBAdobe PDF
Show full item record

Page view(s)

159
checked on Apr 17, 2024

Download(s)

5
checked on Apr 17, 2024

Google ScholarTM

Check

Altmetric