Muscari, Giovanni
Preferred name
Muscari, Giovanni
Email
giovanni.muscari@ingv.it
Staff
staff
ORCID
The search returned 4 results
Now showing 1 - 4 of 4
- Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: Open Access , The development of a new 22 GHz microwave spectrometer for monitoring middle atmospheric water vapour at polar latitudes
(2011-11-07); ; ;Bertagnolio, P. P.; Istituto Nazionale di Geofisica e Vulcanologia, Sezione Roma2, Roma, Italia ;Muscari, G.; Istituto Nazionale di Geofisica e Vulcanologia, Sezione Roma2, Roma, ItaliaWater vapour is a crucial element of the climate system. Accurate observations of stratospheric humidity are needed in the equatorial belt, where water vapour crosses the tropopause, and in the Polar regions, that are affected the most by climate change trends [IPCC, 2007; Solomon et al., 2010]. Satellite-based observations provide atmospheric composition data with extensive spatial and temporal coverage, but these need to be validated and integrated by ground-based networks like GAW and NDACC Changes in middle atmospheric water vapour on time scales longer than the a satellite mission have been successfully observed by ground-based instruments [Nedoluha et al., 2009]. Several ground-based spectrometers have been developed in the last decades to detect the water vapour rotational emission line at 22.235 GHz with heterodyne microwave receivers [e.g., Nedoluha et al., 2009; Straub et al., 2011, Forkman et al., 2003, De Wachter et al., 2011] (see map on the left). The proposed sites for long-term installation of the new spectrometer are Concordia Station, Antarctica (3233 m asl 75.10°S, 123.3°E, NDACC site) or Thule Air Base, Greenland (76.5°N, 68.8°W; NDACC site) for polar monitoring, or Mount Chacaltaya, Bolivia (5.320 m asl, 16.2ºS, 68.1ºW, GAW site) for tropical observations.13030 353 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: Open Access , Intercomparison between Aura MLS and ground-based millimeter-wave observations of stratospheric O3 and HNO3 from Thule (76.5° N, 68.7° W)
(2011-11-07); ; ; ; The Ground-Based Millimeter-wave Spectrometer (GBMS) measures rotational emission spectra of middle atmospheric trace gases, with a spectral window of 600 MHz tunable between approximately 230 and 280 GHz and a resolution of up to 65 kHz. It was designed and built at the State University of New York at Stony Brook in the early 90’s and since then has been regularly upgraded and operated at a variety of sites in both hemispheres, at polar and mid-latitudes. In view of a growing need for long-term data sets of stratospheric constituents, in January 2009 we resolved to establish a long-term GBMS observation site at the Arctic station of Thule Air Base (76.5°N, 68.8°W), Greenland, in order to track the long- and short-term interactions between the changing climate and the seasonal processes tied to the ozone depletion phenomenon. Since then three winter campaigns were carried out from Thule during the period January-March 2009, 2010 and 2011. Observations of O3, HNO3, CO and N2O were performed, mostly on a daily basis, except during periods characterized by poor weather conditions. In this study we compare GBMS stratospheric O3 and HNO3 measurements obtained during these three winter periods at Thule with colocated satellite observations from the Aura Microwave Limb Sounder (MLS) experiment. The Version 3.3 Aura MLS O3 and HNO3 data sets have a resolution of about 2.5 km and 3-4 km, respectively, in the stratosphere. The MLS precisions range from 0.1 to 0.6 ppmv for O3 and about 0.6-0.7 ppbv for HNO3 throughout the stratosphere. Based on preliminary comparisons with correlative data sets and on results obtained for v2.2, systematic uncertainties are estimated to lead to HNO3 measurements biases that vary between ±0.5 and ±2 ppbv and multiplicative errors of ±5 –15% throughout most of the stratosphere. Similarly, a systematic uncertainty of the order of 5-10% has been assessed for O3 data. As for the GBMS, the O3 pure rotational transition line at 276.923 GHz is observed with a ~1.5-hour integration, while the weaker HNO3 spectrum, represented by a cluster of superimposed emission lines centered at 269.1 GHz, needs about 4 hours of integration. Taking advantage of the dependence of the line broadening on atmospheric pressure, inversion techniques allow the retrieval of vertical profiles from approximately 15 to 50 km. In the past, GBMS O3 and HNO3 spectra were deconvolved using a Chahine-Twomey (C-T) and an iterative constrained Matrix Inversion (MI) technique, respectively. More recently, the GBMS retrieval algorithm has been updated to an Optimal Estimation Method (OEM) in order to conform to the standard of the NDACC microwave group, and to easily provide retrievals with a set of averaging kernels that grants more straightforward comparisons with other data sets. The nominal vertical resolution of the retrieved profiles (defined as the FWHM of averaging kernels) is ~8 km for O3 and ~ 12 km for HNO3, although the inversion technique locates the maximum of the mixing ratio profile of both species with a much better accuracy (i.e., ~ ±1 km). The 1σ uncertainty of O3 and HNO3 mixing ratio vertical profiles depends on altitude and is estimated at ~15% or 0.3 ppbv, whichever is larger. Each GBMS profile is compared to the closest MLS profile, with coincidence criteria of ±10° longitude, ±2.5° latitude and ±12 h. In order to avoid of severely compromising the comparison between GBMS and Aura MLS observations due to the much higher resolution of the satellite-derived data sets, we ‘convolved’ the MLS profiles using the GBMS averaging kernels before directly comparing the two data sets. For both species a fairly good agreement between MLS and GBMS profiles is observed, with the GBMS showing, however, a ~10-15% low bias at the mixing ratio peak.370 291 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: Restricted , Development of A 22‐GHz ground‐based spectrometer for middle atmospheric water vapour monitoring
(2010-10-04); ; ; ;Bertagnolio, P. P.; Istituto Nazionale di Geofisica e Vulcanologia, Sezione Roma2, Roma, ItaliaMuscari, G.; Istituto Nazionale di Geofisica e Vulcanologia, Sezione Roma2, Roma, ItaliaWater vapour is a crucial element of the climate system. Accurate observations of stratospheric humidity are needed in the equatorial belt, where most water vapour crosses the tropopause, and in the polar regions, that are most affected by climate change trends. Satellite-based observations provide atmospheric composition data with extensive spatial and temporal coverage, but these need to be validated and integrated by ground-based networks like GAW (Global Atmospheric Watch) and NDACC (Network for Detection of Atmospheric Composition Change). This contribution presents a new ground-based spectrometer for the observation of middle atmospheric humidity profiles being currently developed at INGV - Istituto Nazionale di Geofisica e Vulcanologia. The instrument will detect the water vapour spectral line at 22.235 GHz by using the balanced beam-switching observation technique. The receiver antenna system has a parabolic mirror and a corrugated horn with an overall HPBW of 3.5°. Preliminary tests of the horn performed at the Table Mountain Facility of the Jet Propulsion Laboratory, California are presented. An uncooled GaAsFET low-noise amplifier was custom-assembled for the receiver front-end. The back-end will be a FFT spectrometer with a 1 GHz bandwidth and a 63 kHz resolution which, given the pressure broadening coefficient of the H2O line, will allow to retrieve concentration profiles from about 15 to 80 km altitude. Since the retrieval altitude range is also limited by the spectral signal-to-noise ratio and baseline artifacts, special care is taken in minimizing receiver noise temperature. Low noise temperatures will imply integration times short enough to be able to observe diurnal changes in the lower stratosphere. In order to extend unmanned operation time and limit LN2 supplies at remote stations, calibrated noise sources will be used as cold load reference on a daily basis. The control interface, which is also under development at INGV, will be based on reconfigurable hardware (USB-CPLD). Several different sites are proposed for permanent installation. Among these the GAW sites of Thule Airbase, Greenland for polar monitoring, or Mount Chacaltaya, Bolivia, for tropical tropopause observations.12930 105 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: Restricted , Cross-calibration of UARS and Aura MLS HNO3 data sets by means of ground-based millimeter-wave Observations
(2010-09-27); ; ; ; Nitric acid (HNO3) is a major player in processes controlling the springtime depletion of polar ozone. It is the main constituent of the Polar Stratospheric Clouds (PSCs) and a primary reservoir for reactive nitrogen. Potential variations in the stratospheric circulation and temperature may alter the extent and duration of PSCs activity, influencing the future ozone levels significantly. Monitoring HNO3 and its long-term variability, especially in polar region, is then crucial for better understanding issues related to ozone decline and expected recovery. In this study we present an intercomparison between ground based HNO3 measurements, carried out by means of the Ground-Based Millimeter-wave Spectrometer (GBMS), and two satellite data sets produced by the two NASA/JPL Microwave Limb Sounder (MLS) experiments. In particular, we compare UARS MLS measurements (1991-1999) with those carried out by the GBMS at South Pole, Antarctica (90°S), Fall of 1993 and 1995. A similar intercomparison is made between Aura MLS HNO3 observations (2004 - to date) and GBMS measurements obtained during the period February 2004 - March 2007, at the mid-latitudes/high altitudes station of Testa Grigia (45.9° N, 7.7° E, elev. 3500 m), and during polar winters 2008/09 and 2009/2010 at Thule Air Base (76.5°N 68.8°W), Greenland. We assess systematic differences between GBMS and both UARS and Aura HNO3 data sets at seven potential temperature levels (θ) spanning the range 465 – 960 K. The UARS data set advected to the South Pole shows a low bias, within 20% for all θ levels but the 960 K, with respect to GBMS measurements. A very good agreement, within 5%, is obtained between Aura and GBMS observations at Testa Grigia, while larger differences, possibly due to latitude dependent effects, are observed over Thule. These differences are under further investigations but a preliminary comparison over Thule among MLS v3, GBMS, and ACE-FTS measurements suggests that GBMS measurements carried out during winter 2009 might not be reliable. These comparisons have been performed in the framework of the NASA JPL GOZCARDS project, which is aimed at developing a long-term, global data record of the relevant stratospheric constituents in the context of ozone decline. GBMS has been selected in GOZCARDS since its HNO3 dataset, although sampling different latitudes in different years, is the only one spanning a sufficiently long time interval for cross-calibrating HNO3 measurements by the UARS and Aura MLS experiments.245 44
