    Measurements of low amounts of precipitable water vapor by millimeter wave spectroscopy: An intercomparison with radiosonde, Raman lidar, and Fourier transform infrared data

    Observations of very low amounts of precipitable water vapor (PWV) by means of the Ground-Based Millimeter wave Spectrometer (GBMS) are discussed. Low amounts of column water vapor (between 0.5 and 4 mm) are typical of high mountain sites and polar regions, especially during winter, and are difficult to measure accurately because of the lack of sensitivity of conventional instruments to such low PWV contents. The technique used involves the measurement of atmospheric opacity in the range between 230 and 280 GHz with a spectral resolution of 4 GHz, followed by the conversion to precipitable water vapor using a linear relationship. We present the intercomparison of this data set with simultaneous PWV observations obtained with Vaisala RS92k radiosondes, a Raman lidar, and an IR Fourier transform spectrometer. These sets of measurements were carried out during the primary field campaign of the Earth Cooling by Water vapor Radiation (ECOWAR) project which took place at Breuil-Cervinia (45.9N, 7.6E, elevation 1990 m) and Plateau Rosa (45.9N, 7.7E, elevation 3490 m), Italy, from 3 to 16 March 2007. GBMS PWV measurements show a good agreement with the other three data sets exhibiting a mean difference between observations of 9%. The considerable number of data points available for the GBMS versus lidar PWV correlation allows an additional analysis which indicates negligible systematic differences between the two data sets.
      280  30
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: Open Access ,

    Millimeter wave spectroscopic measurements of stratospheric and mesospheric constituents over the Italian Alps: stratospheric ozone

    Measurements of rotational lines emitted by middle atmospheric trace gases have been carried out from the Alpine station of Testa Grigia (45.9°N, 7.7°E, elev. 3500 m) by means of a Ground-Based Millimeter-wave Spectrometer (GBMS). Observations of species such as O3, HNO3, CO, N2O, HCN, and HDO took place during 4 winter periods, from February 2004 to March 2007, for a total of 116 days of measurements grouped in about 18 field campaigns. By studying the pressure-broadened shape of emission lines the vertical distribution of the observed constituents is retrieved within an altitude range of ∼17-75 km, constrained by the 600 MHz pass band and the 65 kHz spectral resolution of the back-end spectrometer. This work discusses the behavior of stratospheric O3 during the entire period of operation at Testa Grigia. Mid-latitude O3 columnar content as estimated using GBMS measurements can vary by large amounts over a period of very few days, with the largest variations observed in December 2005, February 2006, and March 2006, confirming that the northern winter of 2005-2006 was characterized by a particularly intense planetary wave activity. The largest rapid variation from maximum to minimum O3 column values over Testa Grigia took place in December 2006 and reached a relative value of 72% with respect to the average column content for that period. During most GBMS observation times much of the variability is concentrated in the column below 20 km, with tropospheric weather systems and advection of tropical tropospheric air into the lower stratosphere over Testa Grigia having a large impact on the observed variations in column contents. Nonetheless, a wide variability is also found in middle stratospheric GBMS O3 measurements, as expected for mid-latitude ozone. We find that O3 mixing ratios at ∼32 km are very well correlated with the solar illumination experienced by air masses over the previous ∼15 days, showing that already at 32 km altitude ozone photochemistry dominates over transport processes. The correlation of lower stratospheric ozone concentrations with potential vorticity as an indicator of transport is instead not as clear-cut, due to very complex mixing processes that characterize stratospheric air at mid-latitudes. Correlations of O3 over Testa Grigia with stratospheric tracers such as N2O and HCN, also observed by means of the GBMS, are planned for the future, in order to better characterize lower stratospheric dynamics and therefore lower stratospheric ozone concentrations at mid-latitudes.
      580  362
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: Restricted ,

    Water vapor sounding with the far infrared REFIR-PAD spectroradiometer from a high-altitude ground-based station during the ECOWAR campaign

    (2011-01-28)
    Bianchini, G.
    ;
    Palchetti, L.
    ;
    ; ;
    Di Girolamo, P.
    The Radiation Explorer in the Far InfraRed-Prototype for Applications and Development (REFIR-PAD) spectroradiometer was operated from the Testa Grigia Italian-Alps station in March 2007 during the Earth Cooling by Water Vapour Radiation (ECOWAR) measurement campaign, obtaining downwelling radiance spectra in the 100–1100 cm−1 range, under clear-sky conditions and in the presence of cirrus clouds. The analysis of these measurements has proven that the instrument is capable of determining precipitable water vapor with a total uncertainty of 5–7% by using the far-infrared rotational band of water. The measurement is unaffected by the presence of cirri, whose optical depth can be instead retrieved as an additional parameter. Information on the vertical profiles of water vapor volume mixing ratio and temperature can also be retrieved for three altitude levels. The ability to measure the water vapor column with a simple, uncooled instrument, capable of operating continuously and with a time resolution of about 10 min, makes REFIR-PAD a very valuable instrument for meteorological and climatological studies for the characterization of the water vapor distribution.
      414  32
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: Restricted ,

    Strato-mesospheric ozone measurements using ground-based millimeter-wave spectroscopy at Thule, Greenland

    On January 2009 a ground-based millimeter-wave spectrometer (GBMS) was installed at Thule Air Base (76.5ºN, 68.8ºW), Greenland, for long-term winter monitoring of several stratospheric and mesospheric trace gases in the framework of the Network for the Detection of Atmospheric Composition Change. This work is aimed at characterizing the GBMS O3 vertical profiles between 35 and 80 km altitude obtained by applying the optimal estimation method to O3 pressure-broadened spectral line measurements carried out during three winters. In this altitude range, GBMS O3 retrievals are highly sensitive to variations of the atmospheric state, and their accuracy is estimated to be the larger of 11% or 0.2 ppmv. Comparisons of GBMS O3 profiles with colocated satellite-based measurements from Aura Microwave Limb Sounder (MLS) and Thermosphere Ionosphere Mesosphere Energetics and Dynamics Sounding of the Atmosphere using Broadband Emission Radiometry (SABER) show a good agreement below 65 km altitude once the known 10%–20% high bias of SABER O3 profiles is considered, with the GBMS displaying an averaged low bias of 9% and 17% with respect to MLS and SABER. In the nighttime mesosphere, the GBMS detects the ozone tertiary maximum within 0.1 ppmv (6%) on average with respect to the convolved MLS, SABER, and global 3-D ROSE model profiles but shifts its position to lower altitudes by 4–5 km compared to the height obtained by the other three data sets. In the 50–80 km altitude range, estimates of mesospheric O3 diurnal variation obtained from the GBMS and the convolved satellite measurements agree well within the ±1 standard deviation (~ 0.6 ppmv) of the GBMS mean profile.
      554  75
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: Open Access ,

    Revising the retrieval technique of a long-term stratospheric HNO3 data set: from a constrained matrix inversion to the optimal estimation algorithm

    (2011-07-27) ; ; ;
    Fiorucci, I.; Istituto Nazionale di Geofisica e Vulcanologia, Sezione Roma2, Roma, Italia
    ;
    Muscari, G.; Istituto Nazionale di Geofisica e Vulcanologia, Sezione Roma2, Roma, Italia
    The Ground-Based Millimeter-wave Spectrometer (GBMS) was designed and built at the State University of New York at Stony Brook in the early 1990s and since then has carried out many measurement campaigns of stratospheric O3, HNO3, CO and N2O at polar and mid-latitudes. Its HNO3 data set shed light on HNO3 annual cycles over the Antarctic continent and contributed to the validation of both generations of the satellite-based JPL Microwave Limb Sounder (MLS). Following the increasing need for long-term data sets of stratospheric constituents, we resolved to establish a long-term GMBS observation site at the Arctic station of Thule (76.5 N, 68.8 W), Greenland, beginning in January 2009, in order to track the long- and short-term interactions between the changing climate and the seasonal processes tied to the ozone depletion phenomenon. Furthermore, we updated the retrieval algorithm adapting the Optimal Estimation (OE) method to GBMS spectral data in order to conform to the standard of the Network for the Detection of Atmospheric Composition Change (NDACC) microwave group, and to provide our retrievals with a set of averaging kernels that allow more straightforward comparisons with other data sets. The new OE algorithm was applied to GBMS HNO3 data sets from 1993 South Pole observations to date, in order to produce HNO3 version 2 (v2) profiles. A sample of results obtained at Antarctic latitudes in fall and winter and at mid-latitudes is shown here. In most conditions, v2 inversions show a sensitivity (i.e., sum of column elements of the averaging kernel matrix) of 100±20% from 20 to 45 km altitude, with somewhat worse (better) sensitivity in the Antarctic winter lower (upper) stratosphere. The 1 uncertainty on HNO3 v2 mixing ratio vertical profiles depends on altitude and is estimated at 15% or 0.3 ppbv, whichever is larger. Comparisons of v2 with former (v1) GBMS HNO3 vertical profiles, obtained employing the constrained matrix inversion method, show that v1 and v2 profiles are overall consistent. The main difference is at the HNO3 mixing ratio maximum in the 20–25 km altitude range, which is smaller in v2 than v1 profiles by up to 2 ppbv at mid-latitudes and during the Antarctic fall. This difference suggests a better agreement of GBMS HNO3 v2 profiles with both UARS/ and EOS Aura/MLS HNO3 data than previous v1 profiles.
      420  186
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: Open Access ,

    Ground-based stratospheric O3 and HNO3 measurements at Thule, Greenland: An intercomparison with Aura MLS observations

    (2013-09-23) ; ; ; ;
    Fiorucci, I.; Istituto Nazionale di Geofisica e Vulcanologia, Sezione Roma2, Roma, Italia
    In response to the need for improving our understanding of the evolution and the interannual variability of the winter Arctic stratosphere, in January 2009 a Ground-Based Millimeter-wave Spectrometer (GBMS) was installed at the Network for the Detection of Atmospheric Composition Change (NDACC) site in Thule (76.5° N, 68.8° W), Greenland. In this work, stratospheric GBMS O3 and HNO3 vertical profiles obtained from Thule during the winters 2010 (HNO3 only), 2011 and 2012 are characterized and intercompared with co-located measurements of the Aura Microwave Limb Sounder (MLS) experiment. Using a recently developed algorithm based on Optimal Estimation, we find that the GBMS O3 retrievals show good sensitivity (> 80%) to atmospheric variations between ~ 17 and ~ 50 km, where their 1σ uncertainty is estimated to be the larger of ~ 11% or 0.2 ppmv. Similarly, HNO3 profiles can be considered for scientific use between ~ 17 and ~ 45 km altitude, with a 1σ uncertainty that amounts to the larger of 15% or 0.2 ppbv. Comparisons with Aura MLS version 3.3 observations show that, on average, GBMS O3 mixing ratios are biased negatively with respect to MLS throughout the stratosphere, with differences ranging between ~ 0.3 ppmv (8%) and 0.9 ppmv (18%) in the 17–50 km vertical range. GBMS HNO3 values display instead a positive bias with respect to MLS up to 26 km, reaching a maximum of ~ 1 ppbv (10%) near the mixing ratio profile peak. O3 and HNO3 values from the two datasets prove to be well correlated at all altitudes, although their correlations worsen at the lower end of the altitude ranges considered. Column contents of GBMS and MLS O3 (from 20 km upwards) and HNO3 (from 17 km upwards) correlate very well and indicate that GBMS measurements can provide valuable estimates of column interannual and seasonal variations for these compounds.
      400  289
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: Open Access ,

    Evolution of temperature, O3, CO, and N2O profiles during the exceptional 2009 Arctic major stratospheric warming as observed by lidar and mm-wave spectroscopy at Thule (76.5°N, 68.8°W), Greenland.

    The 2009 Arctic sudden stratospheric warming (SSW) was the most intense event of this kind ever observed. Unique ground-based measurements of middle atmospheric profiles for temperature, O3, CO, and N2O obtained at Thule (76.5°N, 68.8°W), Greenland, in the period January – early March are used to show the evolution of the 2009 SSW in the region of its maximum intensity. The first sign of the SSW was detected at θ~2000 K on January 19, when a rapid decrease in CO mixing ratio took place. The first evidence of a temperature increase was observed at the same level on 22 January, the earliest date on which lidar measurements reached above ~50 km. The warming propagated from the upper to the lower stratosphere in 7 days and the record maximum temperature of 289 K was observed between 1300 and 1500 K potential temperature on 22 January. A strong vortex splitting was associated with the SSW. Stratospheric backward trajectories indicate that airmasses arriving to Thule during the warming peak underwent a rapid compression and an intense adiabatic warming of up to 50 K. The rapid advection of air from the extra-tropics was also occasionally observed to produce elevated values of N2O mixing ratio. Starting from mid-February the temperature profile and the N2O mixing ratio returned to the pre-warming values in the mid and upper stratosphere, indicating the reformation of the vortex at these levels. In late winter, vertical descent from starting altitudes of ~60 km is estimated from CO profiles to be 0.25±0.05 km/day.
      324  650
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: Open Access ,

    VESPA-22: a ground-based microwave spectrometer for long-term measurements of polar stratospheric water vapor

    The new ground-based 22 GHz spectrometer, VESPA-22 (water Vapor Emission Spectrometer for Polar Atmosphere at 22 GHz) measures the 22.23 GHz water vapor emission line with a bandwidth of 500MHz and a frequency resolution of 31 kHz. The integration time for a measurement ranges from 6 to 24 h, depending on season and weather conditions. Water vapor spectra are collected using the beam-switching technique. VESPA-22 is designed to operate automatically with little maintenance; it employs an uncooled front-end characterized by a receiver temperature of about 180K and its quasi-optical system presents a full width at half maximum of 3.5 . Every 30 min VESPA-22 measures also the sky opacity using the tipping curve technique. The instrument calibration is performed automatically by a noise diode; the emission temperature of this element is estimated twice an hour by observing alternatively a black body at ambient temperature and the sky at an elevation of 60 . The retrieved profiles obtained inverting 24 h integration spectra present a sensitivity larger than 0.8 from about 25 to 75 km of altitude during winter and from about 30 to 65 km during summer, a vertical resolution from about 12 to 23 km (depending on altitude), and an overall 1 uncertainty lower than 7% up to 60 km altitude and rapidly increasing to 20% at 75 km. In July 2016, VESPA-22 was installed at the Thule High Arctic Atmospheric Observatory located at Thule Air Base (76.5 N, 68.8 W), Greenland, and it has been operating almost continuously since then. The VESPA-22 water vapor mixing ratio vertical profiles discussed in this work are obtained from 24 h averaged spectra and are compared with version 4.2 of concurrent Aura/Microwave Limb Sounder (MLS) water vapor vertical profiles. In the sensitivity range of VESPA-22 retrievals, the intercomparison from July 2016 to July 2017 between VESPA-22 dataset and Aura/MLS dataset convolved with VESPA-22 averaging kernels shows an average difference within 1.4% up to 60 km altitude and increasing to about 6% (0.2 ppmv) at 72 km.
      197  218
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: Restricted ,

    Cross-calibration of UARS and Aura MLS HNO3 data sets by means of ground-based millimeter-wave Observations

    Nitric acid (HNO3) is a major player in processes controlling the springtime depletion of polar ozone. It is the main constituent of the Polar Stratospheric Clouds (PSCs) and a primary reservoir for reactive nitrogen. Potential variations in the stratospheric circulation and temperature may alter the extent and duration of PSCs activity, influencing the future ozone levels significantly. Monitoring HNO3 and its long-term variability, especially in polar region, is then crucial for better understanding issues related to ozone decline and expected recovery. In this study we present an intercomparison between ground based HNO3 measurements, carried out by means of the Ground-Based Millimeter-wave Spectrometer (GBMS), and two satellite data sets produced by the two NASA/JPL Microwave Limb Sounder (MLS) experiments. In particular, we compare UARS MLS measurements (1991-1999) with those carried out by the GBMS at South Pole, Antarctica (90°S), Fall of 1993 and 1995. A similar intercomparison is made between Aura MLS HNO3 observations (2004 - to date) and GBMS measurements obtained during the period February 2004 - March 2007, at the mid-latitudes/high altitudes station of Testa Grigia (45.9° N, 7.7° E, elev. 3500 m), and during polar winters 2008/09 and 2009/2010 at Thule Air Base (76.5°N 68.8°W), Greenland. We assess systematic differences between GBMS and both UARS and Aura HNO3 data sets at seven potential temperature levels (θ) spanning the range 465 – 960 K. The UARS data set advected to the South Pole shows a low bias, within 20% for all θ levels but the 960 K, with respect to GBMS measurements. A very good agreement, within 5%, is obtained between Aura and GBMS observations at Testa Grigia, while larger differences, possibly due to latitude dependent effects, are observed over Thule. These differences are under further investigations but a preliminary comparison over Thule among MLS v3, GBMS, and ACE-FTS measurements suggests that GBMS measurements carried out during winter 2009 might not be reliable. These comparisons have been performed in the framework of the NASA JPL GOZCARDS project, which is aimed at developing a long-term, global data record of the relevant stratospheric constituents in the context of ozone decline. GBMS has been selected in GOZCARDS since its HNO3 dataset, although sampling different latitudes in different years, is the only one spanning a sufficiently long time interval for cross-calibrating HNO3 measurements by the UARS and Aura MLS experiments.
      244  44
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: Open Access ,

    Intercomparison between Aura MLS and ground-based millimeter-wave observations of stratospheric O3 and HNO3 from Thule (76.5° N, 68.7° W)

    The Ground-Based Millimeter-wave Spectrometer (GBMS) measures rotational emission spectra of middle atmospheric trace gases, with a spectral window of 600 MHz tunable between approximately 230 and 280 GHz and a resolution of up to 65 kHz. It was designed and built at the State University of New York at Stony Brook in the early 90’s and since then has been regularly upgraded and operated at a variety of sites in both hemispheres, at polar and mid-latitudes. In view of a growing need for long-term data sets of stratospheric constituents, in January 2009 we resolved to establish a long-term GBMS observation site at the Arctic station of Thule Air Base (76.5°N, 68.8°W), Greenland, in order to track the long- and short-term interactions between the changing climate and the seasonal processes tied to the ozone depletion phenomenon. Since then three winter campaigns were carried out from Thule during the period January-March 2009, 2010 and 2011. Observations of O3, HNO3, CO and N2O were performed, mostly on a daily basis, except during periods characterized by poor weather conditions. In this study we compare GBMS stratospheric O3 and HNO3 measurements obtained during these three winter periods at Thule with colocated satellite observations from the Aura Microwave Limb Sounder (MLS) experiment. The Version 3.3 Aura MLS O3 and HNO3 data sets have a resolution of about 2.5 km and 3-4 km, respectively, in the stratosphere. The MLS precisions range from 0.1 to 0.6 ppmv for O3 and about 0.6-0.7 ppbv for HNO3 throughout the stratosphere. Based on preliminary comparisons with correlative data sets and on results obtained for v2.2, systematic uncertainties are estimated to lead to HNO3 measurements biases that vary between ±0.5 and ±2 ppbv and multiplicative errors of ±5 –15% throughout most of the stratosphere. Similarly, a systematic uncertainty of the order of 5-10% has been assessed for O3 data. As for the GBMS, the O3 pure rotational transition line at 276.923 GHz is observed with a ~1.5-hour integration, while the weaker HNO3 spectrum, represented by a cluster of superimposed emission lines centered at 269.1 GHz, needs about 4 hours of integration. Taking advantage of the dependence of the line broadening on atmospheric pressure, inversion techniques allow the retrieval of vertical profiles from approximately 15 to 50 km. In the past, GBMS O3 and HNO3 spectra were deconvolved using a Chahine-Twomey (C-T) and an iterative constrained Matrix Inversion (MI) technique, respectively. More recently, the GBMS retrieval algorithm has been updated to an Optimal Estimation Method (OEM) in order to conform to the standard of the NDACC microwave group, and to easily provide retrievals with a set of averaging kernels that grants more straightforward comparisons with other data sets. The nominal vertical resolution of the retrieved profiles (defined as the FWHM of averaging kernels) is ~8 km for O3 and ~ 12 km for HNO3, although the inversion technique locates the maximum of the mixing ratio profile of both species with a much better accuracy (i.e., ~ ±1 km). The 1σ uncertainty of O3 and HNO3 mixing ratio vertical profiles depends on altitude and is estimated at ~15% or 0.3 ppbv, whichever is larger. Each GBMS profile is compared to the closest MLS profile, with coincidence criteria of ±10° longitude, ±2.5° latitude and ±12 h. In order to avoid of severely compromising the comparison between GBMS and Aura MLS observations due to the much higher resolution of the satellite-derived data sets, we ‘convolved’ the MLS profiles using the GBMS averaging kernels before directly comparing the two data sets. For both species a fairly good agreement between MLS and GBMS profiles is observed, with the GBMS showing, however, a ~10-15% low bias at the mixing ratio peak.
      368  289