Item type:Publication, Access status: Restricted , The Gravimetric Station of Brasimone: results of an intercomparison experiment between gravimeters
(2000); ; ; ; Casula, G.; Istituto Nazionale di Geofisica e Vulcanologia, Sezione Bologna, Bologna, ItaliaThe GWR Superconducting Gravimeter (T015) is working continuously in a laboratory of the Research Center of ENEA (Italian National Institute for Energy Development)since 1995 in the frame of Global Geodynamics Project. The data are periodically send to the ICET to be analysed and to produce a valuable tool of high precision monitoring of the global gravity field. The superconducting gravimeter is periodically calibrated by means of a moving mass system with a precision better than 0.3%. In October 1997 a campaign involving the FG5-206 of the Institut de Physique du Globe of Strasbourg was performed in order to verify and to improve the calibration constant of the superconducting gravimeter (SC). The SC calibration constant was computed with the help of absolute gravity and with the mass system. In spite of the large amount of seismic noise present in the data, a good agreement between the two methods, at the 0.1% level, was obtained, improving the calibration factor of the SC gravimeter by a factor of three.154 28 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: Restricted , Calibration of a superconducting gravimeter: a comparison between the mass attraction method and the use of FG5 absolute gravity mesurements
(1999-12); ; ; ; Baldi, P.; Dipartimento di Fisica - Università di Bologna - ItalyThe Superconducting Gravimeter GWR T015 is recording continuously in a laboratory of ENEA (Italian National Institute for Energy Development) at Brasimone site, in the Apennines between Bologna and Florence (Italy). The gravimeter is routinely calibrated by means of a moving mass system with a precision of about 0.3%. In October 1997 a comparison campaign between the absolute gravimeter FG5-206 of EOST (Ecole et Observatorie des Sciences de la Terre) of Strasbourg and the Superconducting Gravimeter (SC) itself has been performed, in order to verify and to improve the precision of the calibration factor of the Sc gravimeter. The seismic noise due to the Umbria-Marche swarm earthquakes didn't effect the measurements, and the result of the comparison campaign agrees with the mass system at a level of 0.06%. The calibration constant of the SC gravimeter has been improved by a factor 2.5.181 30