Skip to main content
The search returned 9 results
Now showing 1 - 9 of 9
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: Open Access ,

    Temporal Variability in Gas Emissions at Bagana Volcano Revealed by Aerial, Ground, and Satellite Observations

    Bagana is a remote, highly active volcano, located on Bougainville Island in southeastern Papua New Guinea. The volcano has exhibited sustained and prodigious sulfur dioxide gas emissions in recent decades, accompanied by frequent episodes of lava extrusion. The remote location of Bagana and its persistent activity have made it a valuable case study for satellite observations of active volcanism. This remoteness has also left many features of Bagana relatively unexplored. Here, we present the first measurements of volcanic gas composition, achieved by unoccupied aerial system (UAS) flights through the volcano's summit plume, and a payload comprising a miniaturized MultiGAS. We combine our measurements of the molar CO2/SO2 ratio in the plume with coincident remote sensing measurements (ground- and satellite-based) of SO2 emission rate to compute the first estimate of CO2 flux at Bagana. We report low SO2 and CO2 fluxes at Bagana from our fieldwork in September 2019, ∼320 ± 76 td −1 and ∼320 ± 84 td −1, respectively, which we attribute to the volcano's low level of activity at the time of our visit. We use satellite observations to demonstrate that Bagana's activity and emissions behavior are highly variable and advance the argument that such variability is likely an inherent feature of many volcanoes worldwide and yet is inadequately captured by our extant volcanic gas inventories, which are often biased to sporadic measurements. We argue that there is great value in the use of UAS combined with MultiGAS-type instruments for remote monitoring of gas emissions from other inaccessible volcanoes.
      53  114
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: Open Access ,

    Combined ground and aerial measurements resolve vent-specific gas fluxes from a multi-vent volcano

    Volcanoes with multiple summit vents present a methodological challenge for determining vent-specific gas emissions. Here, using a novel approach combining multiple ultraviolet cameras with synchronous aerial measurements, we calculate vent-specific gas compositions and fluxes for Stromboli volcano. Emissions from vent areas are spatially heterogeneous in composition and emission rate, with the central vent area dominating passive emissions, despite exhibiting the least explosive behaviour. Vents exhibiting Strombolian explosions emit low to negligible passive fluxes and are CO2-dominated, even during passive degassing. We propose a model for the conduit system based on contrasting rheological properties between vent areas. Our methodology has advantages for resolving contrasting outgassing dynamics given that measured bulk plume compositions are often intermediate between those of the distinct vent areas. We therefore emphasise the need for a vent-specific approach at multi-vent volcanoes and suggest that our approach could provide a transformative advance in volcano monitoring applications.
      147  108
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: Open Access ,

    Ultraviolet Camera Measurements of Passive and Explosive (Strombolian) Sulphur Dioxide Emissions at Yasur Volcano, Vanuatu

    Here, we present the first ultraviolet (UV) camera measurements of sulphur dioxide (SO2) flux from Yasur volcano, Vanuatu, for the period 6–9 July 2018. These data yield the first direct gas-measurement-derived calculations of explosion gas masses at Yasur. Yasur typically exhibits persistent passive gas release interspersed with frequent Strombolian explosions. We used compact forms of the “PiCam” Raspberry Pi UV camera system powered through solar panels to collect images. Our daily median SO2 fluxes ranged from 4 to 5.1 kg s−1 , with a measurement uncertainty of −12.2% to +14.7%, including errors from the gas cell calibration drift, uncertainties in plume direction and distance, and errors from the plume velocity. This work highlights the use of particle image velocimetry (PIV) for plume velocity determination, which was preferred over the typically used cross-correlation and optical flow methods because of the ability to function over a variety of plume conditions. We calculated SO2 masses for Strombolian explosions ranging 8–81 kg (mean of 32 kg), which to our knowledge is the first budget of explosive gas masses from this target. Through the use of a simple statistical measure using the moving minimum, we estimated that passive degassing is the dominant mode of gas emission at Yasur, supplying an average of ~69% of the total gas released. Our work further highlights the utility of UV camera measurements in volcanology, and particularly the benefit of the multiple camera approach in error characterisation. This work also adds to our inventory of gas-based data, which can be used to characterise the spectrum of Strombolian activity across the globe
      62  60
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: Open Access ,

    Dynamics of Outgassing and Plume Transport Revealed by Proximal Unmanned Aerial System (UAS) Measurements at Volcán Villarrica, Chile

    Volcanic gas emissions are intimately linked to the dynamics of magma ascent and outgassing and, on geological time scales, constitute an important source of volatiles to the Earth's atmosphere. Measurements of gas composition and flux are therefore critical to both volcano monitoring and to determining the contribution of volcanoes to global geochemical cycles. However, significant gaps remain in our global inventories of volcanic emissions, (particularly for CO2, which requires proximal sampling of a concentrated plume) for those volcanoes where the near‐vent region is hazardous or inaccessible. Unmanned Aerial Systems (UAS) provide a robust and effective solution to proximal sampling of dense volcanic plumes in extreme volcanic environments. Here we present gas compositional data acquired using a gas sensor payload aboard a UAS flown at Volcán Villarrica, Chile. We compare UAS‐derived gas time series to simultaneous crater rim multi‐GAS data and UV camera imagery to investigate early plume evolution. SO2 concentrations measured in the young proximal plume exhibit periodic variations that are well correlated with the concentrations of other species. By combining molar gas ratios (CO2/SO2 = 1.48–1.68, H2O/SO2 = 67–75, and H2O/CO2 = 45–51) with the SO2 flux (142 ± 17 t/day) from UV camera images, we derive CO2 and H2O fluxes of ~150 t/day and ~2,850 t/day, respectively. We observe good agreement between time‐averaged molar gas ratios obtained from simultaneous UAS‐ and ground‐based multi‐GAS acquisitions. However, the UAS measurements made in the young, less diluted plume reveal additional short‐term periodic structure that reflects active degassing through discrete, audible gas exhalations.
      190  99
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: Open Access ,

    Thermal Imaging Metrology with a Smartphone Sensor

    Thermal imaging cameras are expensive, particularly those designed for measuring high temperature objects with low measurement uncertainty. A wide range of research and industrial applications would benefit from lower cost temperature imaging sensors with improved metrology. To address this problem, we present the first ever quantification methodology for the temperature measurement performance of an ultra-low cost thermal imaging system based on a smartphone sensor. The camera was formed from a back illuminated silicon Complementary Metal Oxide Semiconductor (CMOS) sensor, developed for the smartphone camera market. It was packaged for use with a Raspberry Pi computer. We designed and fitted a custom-made triplet lens assembly. The system performance was characterised with a range of state-of-the-art techniques and metrics: establishing a temperature resolution of below 10 °C in the range 600⁻1000 °C. Furthermore, the scene dependent aspects of combined uncertainty were considered. The minimum angular subtense for which an accurate thermal measurement could be made was determined to be 1.35°, which corresponds to a 23 mm bar at a distance of 1 m, or 45:1 field-of-view in radiation thermometer nomenclature.
      68  97
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: Open Access ,

    Ultraviolet Imaging of Volcanic Plumes: A New Paradigm in Volcanology

    Ultraviolet imaging has been applied in volcanology over the last ten years or so. This provides considerably higher temporal and spatial resolution volcanic gas emission rate data than available previously, enabling the volcanology community to investigate a range of far faster plume degassing processes than achievable hitherto. To date, this has covered rapid oscillations in passive degassing through conduits and lava lakes, as well as puffing and explosions, facilitating exciting connections to be made for the first time between previously rather separate sub-disciplines of volcanology. Firstly, there has been corroboration between geophysical and degassing datasets at ≈1 Hz, expediting more holistic investigations of volcanic source-process behaviour. Secondly, there has been the combination of surface observations of gas release with fluid dynamic models (numerical, mathematical, and laboratory) for gas flow in conduits, in attempts to link subterranean driving flow processes to surface activity types. There has also been considerable research and development concerning the technique itself, covering error analysis and most recently the adaptation of smartphone sensors for this application, to deliver gas fluxes at a significantly lower instrumental price point than possible previously. At this decadal juncture in the application of UV imaging in volcanology, this article provides an overview of what has been achieved to date as well as a forward look to possible future research directions.
      101  70
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: Open Access ,

    Reply to Kern, C. The Difficulty of Measuring the Absorption of Scattered Sunlight by H2O and CO2 in Volcanic Plumes: A Comment on Pering, et al. “A Novel and Inexpensive Method for Measuring Volcanic Plume Water Fluxes at High Temporal Resolution”, Remote Sens. 2017, 9, 146

    We would like to thank our colleague, Christoph Kern, for his comment [1] on our recent paper [2], which provides a valuable adjunct to that published piece. In the comment, Kern details the difficulty of measuring water vapour in volcanic plumes at relatively low altitudes, especially considering the importance of in-plume scattering effects [2]. In particular, Kern [1] suggests that our image-based assessments of plume water amounts at Vulcano Island and Mt. Etna may in fact be more related to in-plume scattering, rather than in-plume water vapour column amounts. This said, we would respectfully argue, that as per the work of others, e.g., [3,4], that an empirical relationship between water and measured in-plume scattering can be established, from which trends in flux data can be determined, provided that sufficiently regular calibrations are performed. This was indeed the key message of the article, and in our case calibration was employed. As Kern remarks, the high ambient concentrations of CO2 and H2O in volcanic plumes do present key challenges to remote sensing of these species in volcano plumes. One key mitigating step is to measure plumes at higher altitude, where the overlying atmospheric column of these species will be reduced. Indeed, the possibility of measuring plume water vapour in this scenario has recently been rather elegantly demonstrated, in the case of Sabancaya volcano in Peru, one of the highest sources of volcanic degassing on the planet
      100  102
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: Open Access ,

    A Low-Cost Smartphone Sensor-Based UV Camera for Volcanic SO2 Emission Measurements

    Recently, we reported on the development of low-cost ultraviolet (UV) cameras, based on the modification of sensors designed for the smartphone market. These units are built around modified Raspberry Pi cameras (PiCams; ≈USD 25), and usable system sensitivity was demonstrated in the UVA and UVB spectral regions, of relevance to a number of application areas. Here, we report on the first deployment of PiCam devices in one such field: UV remote sensing of sulphur dioxide emissions from volcanoes; such data provide important insights into magmatic processes and are applied in hazard assessments. In particular, we report on field trials on Mt. Etna, where the utility of these devices in quantifying volcanic sulphur dioxide (SO2) emissions was validated. We furthermore performed side-by-side trials of these units against scientific grade cameras, which are currently used in this application, finding that the two systems gave virtually identical flux time series outputs, and that signal-to-noise characteristics of the PiCam units appeared to be more than adequate for volcanological applications. Given the low cost of these sensors, allowing two-filter SO2 camera systems to be assembled for ≈USD 500, they could be suitable for widespread dissemination in volcanic SO2 monitoring internationally.
      108  148
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: Open Access ,

    A Novel and Inexpensive Method for Measuring Volcanic Plume Water Fluxes at High Temporal Resolution

    Water vapour (H2O) is the dominant species in volcanic gas plumes. Therefore,measurements of H2O fluxes could provide valuable constraints on subsurface degassing and magmatic processes. However, due to the large and variable concentration of this species in the background atmosphere, little attention has been devoted to monitoring the emission rates of this species from volcanoes. Instead, the focus has been placed on remote measurements of SO2, which is present in far lower abundances in plumes, and therefore provides poorer single flux proxies for overall degassing conditions. Here, we present a new technique for the measurement of H2O emissions at degassing volcanoes at high temporal resolution ( 1 Hz), via remote sensing with low cost digital cameras. This approach is analogous to the use of dual band ultraviolet (UV) cameras for measurements of volcanic SO2 release, but is focused on near infrared absorption by H2O. We report on the field deployment of these devices on La Fossa crater, Vulcano Island, and the North East Crater of Mt. Etna, during which in-plume calibration was performed using a humidity sensor, resulting in estimated mean H2O fluxes of 15 kg s􀀀1 and 34 kg s􀀀1, respectively, in accordance with previously reported literature values. By combining the Etna data with parallel UV camera and Multi-GAS observations, we also derived, for the first time, a combined record of 1 Hz gas fluxes for the three most abundant volcanic gas species: H2O, CO2, and SO2. Spectral analysis of the Etna data revealed oscillations in the passive emissions of all three species, with periods spanning 40–175 s, and a strong degree of correlation between the periodicity manifested in the SO2 and H2O data, potentially related to the similar exsolution depths of these two gases. In contrast, there was a poorer linkage between oscillations in these species and those of CO2, possibly due to the deeper exsolution of carbon dioxide, giving rise to distinct periodic degassing behaviour.
      107  92