Skip to main content
The search returned 15 results
Now showing 1 - 10 of 15
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: Open Access ,

    Health impact of natural gas emission at Cava dei Selci residential zone (metropolitan city of Rome, Italy)

    Natural gas hazard was assessed at Cava dei Selci, a residential neighbourhood of Marino (Rome) by a joint study of gas emissions and related health problems. Here a densely urbanized zone with 4000 residents surrounds a dangerous natural gas discharge where, along the years, dozens of animals were killed by the gas. Gas originates from Colli Albani volcano and consists mostly of CO2 with ~1 vol.% of H2S. In recent years, several gas-related accidents occurred in the urbanized zone (gas blowouts and road collapses). Some houses were evacuated because of hazardous indoor air gas concentration. Gas hazard was assessed by soil CO2 flux and concentration surveys and indoor and outdoor air CO2 and H2S concentration measurements. Open fields and house gardens release a high quantity of CO2 (32.23 tonnes*day-1). Inside most houses, CO2 air concentration exceeds 0.1 vol.%, the acceptable long-term exposure range. In several houses both CO2 and H2S exceed the IDLH level (Immediately Dangerous to Life and Health). An epidemiological cohort study was carried out on the residents of two Cava dei Selci zones with high (ZoneA) and medium (ZoneB) gas hazard exposure, using the rest of Marino as reference zone. We found excess mortality and Emergency Room Visits (ERV) related to high exposure to CO2 and H2S; in particular , an increased risk of mortality and ERV for diseases of central nervous system (HR 1.57, 95% CI 0.76-3.25 and HR 5.82, 95% CI 1.27-26.56 respectively) was found among men living in Zone A.
      502  122
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: Open Access ,

    Assessment of a low-enthalpy geothermal resource and evaluation of the natural CO2 output in the Tor di Quinto area (Rome city, Italy)

    Rome Capital City is located in a high heat flux area of central Italy, suitable for low-enthalpy geothermal exploitation. In the central-northern part of the city, near Tor di Quinto hippodrome close to Tiber River, a wide undeveloped area occurs, which is a possible future urban development site. We present the results of a geochemical and geophysical study aimed at assessing the presence in this zone of a low-enthalpy geothermal aquifer and at evaluating its depth, thickness and the physico-chemical characteristics of the geothermal water. Furthermore the natural CO2 output of this zone has been investigated. A soil CO2 flux survey with 551 measurements over a surface of 3.09 km2 revealed the presence of parallel NW-SE trending positive flux anomalies. The total CO2 output was estimated to 87.77 t*day-1, most of which (85 %) of endogenous or mixed origin. An Electrical Resistivity Tomography survey, consisting of five parallel 355 m long and 100 m spaced profiles, allowed the reconstruction of the stratigraphy of the underground sediments, which are fluvial deposits of the near Tiber River. The geothermal water is hosted in a low-resistivity layer, corresponding to the Tiber base gravels, which are here 20 m thick and whose top is 40 m below the surface. The water has a nearly constant temperature of 17.5 °C, a relatively high salinity and an appreciable content in dissolved gas. This low-enthalpy resource is suitable for direct uses, e.g. individual and district heating/cooling, sanitary hot water, spa facilities for swimming and bathing.
      531  145
  • Some of the metrics are blocked by your 
    Item type:Product, Access status: Open Access ,
      84  87
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: Open Access ,

    Continuous monitoring of CO2 and H2S air concentration and soil CO2 flux survey for gas hazard assessment at Tor Caldara nature reserve (Anzio, Italy).

    Tor Caldara natural reserve hosts the southernmost discharge of endogenous gas of Colli Albani volcano (mostly CO2 with a relevant H2S content up to 6.3 vol.%). Gas discharges in zones where past sulfur mining removed the impervious surficial cover (e.g. Miniera Grande and Miniera Piccola) and along tectonic fissures. A structural study of the reserve has shown the presence of two zones with different characteristics: prevailing directions NS and N30° in the northern zone; EW and N60° in the southern one. In MarchJuly 2012 a geochemical study was carried out, including a soil CO2 flux survey and continuous monitoring (from 2 to 11 days) of air concentration of CO2 and H2S in 12 sites of the reserve. Environmental parameters were also monitored. Total diffuse soil flux of endogenous CO2 was estimated to 17.48 ton*day1 from 1,259 measurements over a 0.47 km2 surface, with 6.56 ton*day1 only from Miniera Grande. This is the second highest value of soil CO2 flux at Miniera Grande, after that of 2005 (9.25 ton*day1) and is significantly higher than in 2009 (1.20 ton*day1). As both the 2005 and 2012 surveys were made shortly after earthquakes with epicentres near to Tor Caldara (max ML= 4.7 in 2005 and 3.5 in 2012), data confirm that soil CO2 flux increases during earthquakes because of seismic rock microfracturing and soil shaking. Hazardous air concentrations have been found only for H2S, up to immediately lethal values (5651,124 ppm) and with potentially lethal values (≥ 250 ppm) long persisting (up to 12h27’) in several no wind nights. Instead, the CO2 air concentration remained always well below dangerous levels (maximum recorded value = 2.1 vol.%). The most hazardous gas releasing sites were found in Miniera Grande and in a small pond NE of Miniera Piccola, where the carcasses of mammals and other small animals are frequently found. The killer gas is H2S, and the dangerous sites should be appropriately fenced to prevent access to people and animals.
      690  197
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: Open Access ,

    Using a multi-method approach based on soil radon deficit, resistivity, and induced polarization measurements to monitor non-aqueous phase liquid contamination in two study areas in Italy and India

    Geochemical and geophysical surveys employing radon deficit, resistivity, and induced polarization (IP) measurements were undertaken on soil contaminated with non-aqueous phase liquids (NAPLs) in two different sites in India and in Italy. Radon deficit, validated through the comparison with average soil radon in reference unpolluted areas, shows the extension of contamination in the upper part of the unsaturated aquifers. In site 1 (Italy), the spill is not recent. A residual film of kerosene covers soil grains, inhibiting their chargeability and reducing electrical resistivity difference with background unpolluted areas. No correlation between the two parameters is observed. Soil volatile organic compounds (VOCs) concentration is not linked with radon deficit, supporting the old age of the spillage. NAPL pollution in sites 2a and 2b (India) is more recent and probably still active, as demonstrated by higher values of electrical resistivity. A good correlation with IP values suggests that NAPL is still distributed as droplets or as a continuous phase in the pores, strengthening the scenario of a fresh spill or leakage. Residual fraction of gasoline in the pore space of sites 2a and 2b is respectively 1.5 and 11.8 kg per cubic meter of terrain. This estimation is referred to the shallower portion of the unsaturated aquifer. Electrical resistivity is still very high indicating that the gasoline has not been strongly degraded yet. Temperature and soil water content influence differently radon deficit in the three areas, reducing soil radon concentration and partly masking the deficit in sites 2a and 2b.
      134  190
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: Restricted ,

    Soil radon survey to assess NAPL contamination from an ancient spill. Do kerosene vapors affect radon partition ?

    A soil radon-deficit survey was carried out in a site polluted with kerosene (Rome, Italy) in winter 2016 to assess the contamination due to the NAPL residual component in the vadose zone and to investigate the role of the vapor plume. Radon is indeed more soluble in the residual NAPL than in air or water, but laboratory experiments demonstrated that it is also preferentially partitioned in the NAPL vapors that transport it and may influence soil radon distribution patterns. Specific experimental configurations were designed and applied to a 31-station grid to test this hypothesis; two RAD7 radon monitors were placed in-series and connected to the top of a hollow probe driven up to 80-cm depth; the first instrument was directly attached to the probe and received humid soil gas, which was counted and then conveyed to the second monitor through a desiccant (drierite) cylinder capturing moisture and eventually the NAPL volatile component plus the radon dissolved in vapors. The values from the two instruments were cross-calibrated through specifically designed laboratory experiments and compared. The results are in agreement within the error range, so the presence of significant NAPL vapors, eventually absorbed by drierite, was ruled out. This is in agreement with low concentrations of soil VOCs. Accordingly, the radon-deficit is ascribed to the residual NAPL in the soil pores, as shown very well also by the obtained maps. Preferential areas of radon-deficit were recognised, as in previous surveys. An average estimate of 21 L (17 Kg) of residual NAPL per cubic meter of terrain is provided on the basis of original calculations, developed from published equations. A comparison with direct determination of total hydrocarbon concentration (23 kg per cubic meter of terrain) is provided.
      139  1
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: Restricted ,

    Laboratory simulation of recent NAPL spills to investigate radon partition among NAPL vapours and soil air

    Soil radon is employed to trace residual NAPL (Non-Aqueous Phase Liquid) contamination because it is very soluble in these substances and is strongly depleted over polluted volumes of the subsoil. The solubility of radon into NAPL vapors, generally poorly considered, is investigated here, either as growth of radon exhalation from a material contaminated with increasing volumes of kerosene, or as radon partition between liquid kerosene, water and total air, considered ad the sum of kerosene vapors plus air.
      121  2
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: Restricted ,

    Correcting for H2O interference using a RAD7 electrostatic collection-based silicon detector

    The effect of water molecules on the electrostatic collection of 218Po ions onto the surface of silicon detectors (neutralization) is evaluated through the comparison with a scintillation cell (ZnS), not affected by air humidity. A radon monitor (RAD7, Durridge Company) was connected to a stainless steel radon chamber, equipped with the scintillation cell. Radon gas, extracted from an acidified RaCl2 source, was injected into the chamber and the amount of water molecules in the system was alternatively lowered or increased (from 0.00075 to 0.014 g of water in RAD7) by connecting the chamber to a desiccant or to a bubbling water bottle. The relative efficiency of the silicon detector with respect to the scintillation cell decreases with the growth of water molecules inside RAD7. This dependence, with a fixed i) electrostatic chamber geometry and ii) nominal high voltage, diverges during the humidification or the drying phase because it is in turn influenced by the length of interaction of polonium atoms with water molecules, which impacts on the size of 218Po clusters and thus on the neutralization process. For water contents higher that 0.01 g in RAD7, this effect is greatly enhanced. Temperature in the investigated range (18.5-35.6 °C) does not affect the efficiency of electrostatic collection-based silicon detectors. Based on these experiments, admitting a certain error on the efficiency (from 1.8 to 7.5%, depending on the water content), proper corrections were developed to adjust soil radon readings, when a desiccant is removed. This operation is necessary if recent Non-Aqueous Phase Liquids (NAPLs) leakage has occurred in the subsoil to avoid the sorption and possible later release of radon by Drierite, with related partition between the solid and liquid phases (water and NAPL).
      102  475