Skip to main content
The search returned 33 results
Now showing 1 - 10 of 33
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: Open Access ,

    SEISMOLOGICAL ANALYSIS OF THE 1917 MONTERCHI EARTHQUAKE (CENTRAL APENNINES, ITALY) FOR SEISMOTECTONIC IMPLICATIONS

    On April 26, 1917 at 9:35:59 (GMT) an earthquake occurred in the Sansepolcro Basin (the northernmost portion of the High Tiber Valley - Italy) producing large damages and fatalities. This event, noted as Monterchi earthquake, is well constrained in the Catalogue of Strong Italian Earthquakes (Boschi et al., 2000) by 134 felt reports locations, mainly distributed on the right side of the Tiber Valley, mostly affecting the towns of Monterchi, Citerna and surrounding localities. The maximum and epicentral intensity was determined as Io=IX-X degree of the MCS scale corresponding to an equivalent magnitude of Me=6 that define this event as the most important of the region. The Sansepolcro Basin was generated on the hanging-wall of the Altotiberina Fault (ATF) system. The ATF system is composed by an E-dipping low-angle normal fault, active at least since the Late Pliocene, that represents one of the main regional detachments of the Northern Apennines, and its antithetic W-dipping high-angle normal faults (Barchi, et al., 2009, Boncio et al., 2000). Although the southern part of the ATF was demonstrated to creep (Piccinini et al., 2003), its capability to generate strong or moderate earthquakes is still debated and the historical seismicity that affected the region was not associated to specific geologic sources. For these reasons the study of the Monterchi earthquake plays an important role in the debate. On this light, many authors tried to define the main seismic source parameters through the analysis of historical seismograms and respective bulletins. Preliminary results were presented at previous ECEES, ESC and EGU congresses (Caciagli et al., 2006, Ciaccio et al., 2008, Bernardi et al., 2009). In all these works the hypocentre of the Monterchi earthquake has been substantially unresolved, because of the absolute P and S-phases use, and, for this reason, its epicentre was located 20 km North of the macroseismic one. Concerning the focal mechanism, Bernardi et al. (2009) proposed a moment tensor solution for the Monterchi event, based on almost horizontal recordings from 4 stations situated in a very small azimuthal range. Independently of the validity of the normal fault mechanism proposed by Bernardi et al (2009) their conclusions fit perfectly in the context of the seismotectonic setting of the ATF, but do not account for the discrepancy between the instrumental and the macroseismic epicentres. Today, 49 seismograms from 19 different Euro-Mediterranean observatories are available in the database of the SISMOS Project – INGV (http://sismos.rm.ingv.it/) The BAAS (British Association for Advancement of Sciences) bulletin of 1917, although if incomplete because of the 1st World War, reports a list of 21 seismological observatories that recorded the P and S-phases for this earthquake. Additionally to this database, we included additional arrival-times deriving from further seismic bulletins not contained in the BAAS reports and from directly digitizing original historical seismograms. An incisive approach to analyse these different data allows us to obtain a new, robust and consistent hypocentral solution, coherent with the macroseismic data, in particular by using S-P travel time differences for recordings where the absolute timing is uncertain. An accurate research on the technical characteristics of the recording historical seismometers (period, damping, gain etc), including the analysis of the instrumental natural period recorded in some seismograms, allows to deconvolute the original digitized seismic traces in order to evaluate the potential of moment tensor inversion, to determine the main seismic parameters (Mo, Mw, Circular Fault Radius), and to implement the solution in the framework of the regional tectonic setting.
      185  166
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: Open Access ,

    The seismic sequence of 30 th May - 9 th June 2016 in the geothermal site of Torre Alfina (central Italy) and related variations in soil gas emissions

    In the framework of a medium-enthalpy geothermal exploitation project, seismicity and soil gas emissions have been monitored in the area of Castel Giorgio - Torre Alfina (central Italy) since 2014. A dedicated local seismic network, called ReMoTA, allows deepening of the knowledge of the natural local seismicity in terms of source mechanisms, high-quality event localization and magnitude estimation. From November 2014 to May 2016, ReMoTA recorded 846 seismic events with a magnitude range of Md 0.1 to ML 2.8 and with hypocentres between 4 and 8 km depth. Most of these events occurred in six short lasting clusters. On 30th May 2016 a Mw 4.3 earthquake occurred near Castel Giorgio, followed by almost 1700 aftershocks. The moment tensor solution for the main shock depicts a WNW-ESE oriented normal fault with small right-lateral strike component. An overview of the epicentral distribution of the different clusters recorded since 2014, highlights that the active tectonic structures are orientated principally along the NE - SW and WNW-ESE directions. The relocation of the 1957 Me 4.9 historical earthquake suggests that this event occurred in the same fault system as the 2016 seismic sequence. In the study area, there is only one natural emergence (Solfanare) emitting a CO2 dominated gas, having the same chemical and isotopic composition of the gas contained in a cap at the summit of the geothermal reservoir. Apart from small perturbations, no significant compositional variations, were recorded during the 2016 seismic sequence in the gas of the Solfanare vents that was also analyzed continuously by an automatic gas-chromatographic station. The diffuse soil CO2 flux is monitored since 2013 in six target areas located around the future production and reinjection wells, in order to assess the level of background natural degassing. In all target areas the maximum value of soil CO2 flux has been recorded during the 2016 seismic sequence. However, values remained relatively low (maximum 112 g ⋅m−2 ⋅d−1) and the values of δ13C of the emitted CO2 (-25.25 to -24.22 ‰ vs. PDB) indicated a shallow biological origin of the gas (by soil respiration). Only at Solfanare high values of diffuse soil CO2 flux were recorded up to a maximum of 20,125 g ⋅m−2 ⋅d−1). All the seismicity of the May - June 2016 sequence is located above the ML4.1 main event and is distributed on small distinct faults (such as at San Lorenzo Nuovo, Acquapendente, etc.) and triggered by the main shock. The source mechanism provided by the full moment tensor indicates that rupture processes at depth probably deviate from a pure normal fault. The significant contribution of CLVD and isotropic components suggest a possible opening of fluid cracks below the geothermal reservoir hosted in fractured Mesozoic limestones. In spite of the increase of the CO2 flux, no significant changes have been observed in the chemical and isotopic composition of the Solfanare gas. The seismo-tectonic scenario indicates that the Solfanare fault was not activated. Kinematics and orientation of the activated faults suggest a relationship with the Bolsena caldera collapse.
      997  328
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: Open Access ,

    On the uncertainties of seismic parameters: a Bayesian framework for their estimation using Brune's model

    (2012-12-03) ; ;
    Selva, Jacopo
    ;
    Caciagli, Marco; Istituto Nazionale di Geofisica e Vulcanologia, Sezione Bologna, Bologna, Italia
    ;
    Garcia-Aristizabal, Alexander; AMRA
    The estimation of seismic parameters from ground-motion records is subject to many uncertainties, such as: (i) parameterization, modeling procedures and underlying hypotheses, (ii) approximated input parameters, (iii) instrumental errors on records and their impact in data post-processing, (iv) procedures to estimate model’s parameters. However these uncertainties are rarely treated and propagated to the final results. For example, on one side, density of rocks, velocity model, geometrical spreading, radiation pattern are just some of the common parameters needed to estimate the main seismic parameters of an earthquake and are generally used as average values. On the other side, uncertainties derived from the acquisition system and processing of the data are often neglected. Nevertheless, in many cases these uncertainties may be particularly important, as for example in the analysis of historical earthquakes, where both instrumental response and treatment of analog records intrinsically imply non negligible sources of uncertainty. Here, we present a new Bayesian procedure to estimate seismic parameters that allows: (i) to obtain a robust estimation of the Brune’s model parameters (Brune 1970, 1971) and relatives uncertainties, (ii) to account for the uncertainty related to the Earth model, and (iii) to propagate such uncertainties on the estimation of seismological parameters (seismic moment, moment magnitude, radius of the circular source zone and static stress drop). It is important to highlight that this study does not want to discuss the validity or the physical significance of the Brune’s model, but it is focused on the details of how to fit it on a dataset in order to evaluate the seismological parameters, accounting and properly propagating a rather large range of uncertainties. These capabilities of the proposed procedure are finally demonstrated through an illustrative application analyzing seismic records from historical events.
      174  400
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: Open Access ,
      196  534
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: Open Access ,

    Design and realization of a seismic monitoring system for the geothermal production site of Torre Alfina (Italy)

    The geothermal field of Torre Alfina is located in Central Italy, at the boundary between the regions Tuscany and Latium, at the northern extremity of the Vulsini quaternary volcanic complex. Geochemical and geophysical wells drilled in the 1970s and 1980s down to depths ranging from 563 m to 2710 m revealed that Torre Alfina is a medium- enthalpy (T = 140$\,^{\circ}$ C) geothermal field, hosted in buried fractured Mesozoic limestones. Recently a multi-national industrial company received the license for the production of geothermal energy up to a maximum of 5 MW. In 2013 the INGV was commissioned to realize a monitoring system that includes the observation of gas emissions, microseismicity and ground deformation. National guidelines published recently by the Italian Ministry of Economic Development (MISE) regulate in detail the governmental monitoring ordinances exclusively regarding the extraction of hydrocarbons and the fluid injection due to wastewater and CO2 storage but concerning geothermal energy production appropriate regulations are missing. Following the recommendations, described in the Ministerial Decree that regulates the geothermal production activity, the seismic monitoring system should be capable to record (i) the local microseismicity during the phase of geothermal energy production and (ii) the natural seismicity already 12 months before the beginning of the production operations. In 2014 we started to install a seismic network consisting of 5 short period stations within a radius of 5 km (Inner Domain) and thereafter further 5 stations inside an area with a 10 km radius (Outer Domain). The seismic noise level recorded at the single stations is unfavorably high, due to an intensive colonization and numerous settlements of small and medium industries. Transients as well as persistent monochromatic disturbances are recorded very well especially at the southern stations, probably due to a low wave energy dissipation inside the layer of quaternary volcanic rocks.
      49  90
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: Open Access ,

    Surface ruptures following the 30 October 2016 Mw 6.5 Norcia earthquake, central Italy

    We present a 1:25,000 scale map of the coseismic surface ruptures following the 30 October 2016 M-w 6.5 Norcia normal-faulting earthquake, central Italy. Detailed rupture mapping is based on almost 11,000 oblique photographs taken from helicopter flights, that has been verified and integrated with field data (>7000 measurements). Thanks to the common efforts of the Open EMERGEO Working Group (130 people, 25 research institutions and universities from Europe), we were able to document a complex surface faulting pattern with a dominant strike of N135 degrees-160 degrees (SW-dipping) and a subordinate strike of N320 degrees-345 degrees (NE-dipping) along about 28km of the active Mt. Vettore-Mt. Bove fault system. Geometric and kinematic characteristics of the rupture were observed and recorded along closely spaced, parallel or subparallel, overlapping or step-like synthetic and antithetic fault splays of the activated fault systems, comprising a total surface rupture length of approximately 46km when all ruptures were considered.
      6036  226
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: Open Access ,

    On the seismicity recorded in the geothermal area of Mt. Amiata. (Oral Presentation - ESC2016-461)

    Mt. Amiata in Tuscany (Italy) is an extinct volcano whose last eruptive activity was dated about 200 ky ago. Being still characterized by a high geothermal gradient the area lends itself for geothermal exploitation. Beneath the Tuscan Geothermal Areas seismicity is exclusively observed in the upper crust and is confined in depth by the so called K-horizon (400°C isotherme). The structure above contains permeable layers of highly fractured, volcanic rocks saturated with hot water and steam. Geothermal exploitation from these layers started in the 1960’s. Shallow earthquakes have occurred close to the geothermal wells, and the question is raised whether these event are of natural origin or related to the exploitation of heat. To monitor the seismic activity inside the geothermal field, an 8 station seismic network and a 7 element small aperture seismic array were installed in 2015 in the vicinity of the geothermal power plants during a joint field experiment by the Istituto Nazionale di Geofisica e Vulcanologia, the University of Potsdam and the GFZ-German Research Center of Geoscience. Already during the first 24 hours of seismic recording the array and the neighboring network stations recorded a M0.5 seismic event in the vicinity of the geothermal field of Bagnore. Since then micro-earthquake activity was recorded regularly. One of the main challenges of the seismic array/network installation, deployed in direct proximity to the geothermal energy production, is to identify seismic events caused by human operations. As hypocenters are located close to the geothermal power plants, at a similar depth as the production level, it is very difficult - if not impossible - to discriminate between natural earthquakes and anthropogenic events. The main goal of the seismic array/network deployed in the framework of our project is to shed some additional light on this question. The monitoring capabilities of the recording system permit a lowering of the detection threshold for local seismic events, performing high-resolution hypocentral determination, especially in the vicinity of the industrial operations, and calculating focal mechanisms. Array techniques and relative location methods will be used for a precise hypocentral determination. Polarization and spectral analysis, will be applied to discriminate seismic recordings from Mt. Amiata that sometimes resemble rather volcano-seismic waveforms with long-period characteristics, than typical tectonic events.
      136  190
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: Open Access ,

    Coseismic effects of the 2016 Amatrice seismic sequence: first geological results

    Since the beginning of the ongoing Amatrice seismic sequence on August 24, 2016, initiated by a Mw 6.0 normal faulting earthquake, the EMERGEO Working Group (an INGV team devoted to earthquake aftermath geological survey) investigated coseismic effects on the natural environment. Up to now, we surveyed about 750 km2 and collected more than 3200 geological observations including differently oriented tectonic fractures together with intermediate- to small- sized landslides. The most impressive coseismic evidence was found along the known active Mt. Vettore fault system, where surface ruptures with clear vertical/horizontal offset were observed for more than 5 km, while unclear and discontinuous coseismic features were recorded along the Laga Mts. Fault systems.
      4889  340
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: Open Access ,

    Surface ruptures following the 26 December 2018, Mw 4.9, Mt. Etna earthquake, Sicily (Italy)

    We present a 1:10,000 scale map of the coseismic surface ruptures following the 26 December 2018 Mw 4.9 earthquake that struck the eastern flank of Mt. Etna volcano (southern Italy). Detailed rupture mapping is based on extensive field surveys in the epicentral region. Despite the small size of the event, we were able to document surface faulting for about 8 km along the trace of the NNW-trending active Fiandaca Fault, belonging to the Timpe tectonic system in the eastern flank of the volcano. The mapped ruptures are characterized in most cases by perceivable opening and by a dominant right-oblique sense of slip, with an average slip of about 0.09 m and a peak value of 0.35 m. It is also noteworthy that the ruptures vary significantly in their kinematic expression, denoting locally high degree of complexity of the surface faulting.
      3992  256
  • Some of the metrics are blocked by your 
    Item type:Publication, Access status: Open Access ,

    Microseismicity recorded before geothermal exploitation at Torre Alfina (Italy), (Poster Session - ESC2016-464)

    The geothermal field of Torre Alfina is located in Central Italy at the northern extremity of the Vulsini quaternary volcanic complex. Wells drilled in the 1970s and 1980s down to depths ranging from 563 to 2710 m revealed that Torre Alfina is a medium-enthalpy (T=140 C) geothermal field, hosted in buried fractured Mesozoic limestones. Recently a multinational industrial company received the license for the production of geothermal energy up to a maximum of 5 MW. In 2013, the INGV was commissioned to realize a monitoring system that includes the observation of gas emissions, microseismicity and ground deformation. Following the recommendations, described in the Ministerial Decree that regulates the geothermal production activity, the seismic monitoring system should be capable to record the local microseismicity during the phase of geothermal energy production and the natural seismicity since 12 months before the beginning of the production operations. In 2014, we started to install a short-period seismic network called ReMoTA near the future geothermal production site of Torre Alfina. Stations are equipped with 24 bit digitizers and short-period seismometers. The seismic noise level recorded at the single stations is unfavorably high, due to an intensive colonization and numerous settlements of small and medium industries. Transients as well as persistent monochromatic disturbances are recorded very well especially at the southern stations, probably due to a low wave energy dissipation inside the layer of quaternary volcanic rocks. During the period from June 2014 – November 2015 ReMoTA recorded 289 local earthquakes and 19 quarry blasts, with respect to 46 seismic events reported by ISIDE. The depth distribution of the seismic events recorded during 18 months before the beginning of the geothermal exploitation is concentrated inside the upper crust at a depth range between 4 - 8 km. The spatial distribution of the hypocenters seems to dip slightly towards SW beneath the area of Torre Alfina. This tendency together with the focal solutions of the Dec 2014 seismicity cluster highlights the presence of a normal fault with a weak transverse component striking in NW-SE-direction, within splitting distance to the future geothermal production site. The other two seismicity cluster of Mar-2015 and Nov-2015 seem to delineate antithetic structures with respect to the main fault. Considering that the future production level will be at a depth range between 1500 – 2300 m, and being aware of the hypocentral uncertainties, the discrimination between “natural” earthquakes and seismicity triggered by anthropic activity will be an important challenge.
      195  230