Earth-prints repository, logo   DSpace

About DSpace Software
|earth-prints home page | roma library | bologna library | catania library | milano library | napoli library | palermo library
Please use this identifier to cite or link to this item: http://hdl.handle.net/2122/5179

Authors: Lombardo, V.*
Harris, A. J. L.*
Calvari, S.*
Buongiorno, M. F.*
Title: Spatial variations in lava flow field thermal structure and effusion rate derived from very high spatial resolution hyperspectral (MIVIS) data
Title of journal: Journal of Geophysical Research
Series/Report no.: /114(2009)
Publisher: AGU
Issue Date: 2009
DOI: 10.1029/2008JB005648
Keywords: effusion rate
satellite measurements
Abstract: High spatial resolution hyperspectral measurements of volcanic thermal anomalies allow for an unconstrained solution of a two-component thermal model. This can be used for identification of lava flow emplacement style and the calculation of lava flow heat and volume flux. The multispectral infrared and visible imaging spectrometer (MIVIS) is an airborne sensor equipped with 72 bands in the short infrared range and 10 bands in the thermal infrared region of the spectrum. We used MIVIS acquired for Mount Etna (Italy) during the July–August 2001 eruption to solve the dual band equations in an unconstrained fashion using three bands of unsaturated data. Our results suggest a complex thermal structure for Etnean lava flows. This is characterized by a downflow transition from a lightly crusted active channel to a more heavily crusted distal section, both surrounded by zones of stagnant cooling flow where exposed molten material is absent and maximum temperatures are thus lower. The total flow field effusion rate obtained for 29 July 2001 (0700 local time) of 8–16 m3/s is in excellent agreement with that obtained from ground-based measurements and Advanced Very High Resolution Radiometer data. Flow-by-flow effusion rates obtained from the MIVIS data vary depending on whether the vent is linked to the central conduit or the dyke that was injected from greater depth, as well as vent elevation, with lower elevation vents experiencing higher effusion rates.
Appears in Collections:04.03.06. Measurements and monitoring
Papers Published / Papers in press

Files in This Item:

File Description SizeFormatVisibility
Lombardo et al 2009.pdfMain article886.2 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.


Share this record
Del.icio.us

Citeulike

Connotea

Facebook

Stumble it!

reddit


 

Valid XHTML 1.0! ICT Support, development & maintenance are provided by CINECA. Powered on DSpace Software. CINECA