Please use this identifier to cite or link to this item: http://hdl.handle.net/2122/12644
Authors: Huret, Nathalie* 
Segonne, Charlotte* 
Payan, Sébastien* 
Salerno, Giuseppe* 
Catoire, Valéry* 
Ferrec, Yann* 
Roberts, Tjarda* 
Pola Fossi, Armande* 
Rodriguez, Delphy* 
Croizé, Laurence* 
Chevrier, Stéphane* 
Langlois, Stéphane* 
La Spina, Alessandro* 
Caltabiano, Tommaso* 
Title: Infrared Hyperspectral and Ultraviolet Remote Measurements of Volcanic Gas Plume at MT Etna during IMAGETNA Campaign
Journal: Remote Sensing 
Series/Report no.: /11 (2019)
Issue Date: 2019
DOI: 10.3390/rs11101175
Keywords: volcanic plume
hyperspectral
radiative transfer
data retrieval
remote sensing
Abstract: Quantification of gaseous emission fluxes from volcanoes can yield valuable insights on processes occurring in the Earth’s interior as part of hazard monitoring. It is also an important task in the framework of climate change, in order to refine estimates of natural emissions. Passive open-path UltraViolet (UV) scattered observation by UV camera allows the imaging of volcanic plumes and evaluation of sulfur dioxide (SO2) fluxes at high temporal resolution during daytime. Another technique of imaging is now available in the InfraRed (IR) spectral domain. Infrared hyperspectral imagers have the potential to overcome the boundary of daytime sampling of the UV, providing measurements also during the night and giving access simultaneously to additional relevant gas species. In this context the IMAGETNA campaign of measurements took place at Mt Etna (Italy) in June 2015. Three di erent IR imagers (commercial and under developments) were deployed, together with a Fourier Transform InfraRed spectrometer (FTIR) instrument, a UV camera, a LongWavelength InfraRed (LWIR) camera and a radiometer. We present preliminary results obtained by the two IR cameras under development, and then the IR hyperspectral imager results, coming from full physics retrieval, are compared to those of the UV camera. The comparison points out an underestimation of the SO2 Slant Column Densities (SCD) of the UV camera by a factor of 3.6. The detailed study of the retrieved SO2 SCD highlights the promising application of IR imaging in volcanology for remotely volcanic plume gas measurements. It also provides a way to investigate uncertainties in the SO2 SCD imaging in the UV and the IR.
Appears in Collections:Article published / in press

Files in This Item:
File Description SizeFormat
Huret et 2019 al., .pdf8.36 MBAdobe PDFView/Open
Show full item record

WEB OF SCIENCETM
Citations 50

1
checked on Feb 7, 2021

Page view(s)

452
checked on Apr 27, 2024

Download(s)

107
checked on Apr 27, 2024

Google ScholarTM

Check

Altmetric