Please use this identifier to cite or link to this item: http://hdl.handle.net/2122/10675
Authors: Trolese, Matteo* 
Giordano, Guido* 
Cifelli, Francesca* 
Winkler, Aldo* 
Mattei, Massimo* 
Title: Forced transport of thermal energy in magmatic and phreatomagmatic large volume ignimbrites: Paleomagnetic evidence from the Colli Albani volcano, Italy
Journal: Earth and Planetary Sciences Letters 
Series/Report no.: /478 (2017)
Issue Date: 15-Nov-2017
DOI: 10.1016/j.epsl.2017.09.004
Keywords: Colli Albani
thermal remanent magnetization
emplacement temperature
large volume eruption
magmatic/phreatomagmatic ignimbrite
Abstract: Few studies have detailed the thermal architecture of large-volume pyroclastic density current deposits, although such work has a clear importance for understanding the dynamics of eruptions of this magnitude. Here we examine the temperature of emplacement of large-volume caldera-forming ignimbrites related to magmatic and phreatomagmatic eruptions at the Colli Albani volcano, Italy, by using thermal remanent magnetization analysis on both lithic and juvenile clasts. Results show that all the magmatic ignimbrites were deposited at high temperature, between the maximum blocking temperature of the magnetic carrier (600–630 °C) and the glass transition temperature (about 710 °C). Temperature estimations for the phreatomagmatic ignimbrite range between 200 and 400 °C, with most of the clasts emplaced between 200 and 320 °C. Because all the investigated ignimbrites, magmatic and phreatomagmatic, share similar magma composition, volume and mobility, we attribute the temperature difference to magma–water interaction, highlighting its pronounced impact on thermal dissipation, even in large-volume eruptions. The homogeneity of the deposit temperature of each ignimbrite across its areal extent, which is maintained across topographic barriers, suggests that these systems are thermodynamically isolated from the external environment for several tens of kilometers. Based on these findings, we propose that these large-volume ignimbrites are dominated by the mass flux, which forces the lateral transport of mass, momentum, and thermal energy for distances up to tens of kilometers away from the vent. We conclude that spatial variation of the emplacement temperature can be used as a proxy for determining the degree of forced-convection flow.
Appears in Collections:Article published / in press

Files in This Item:
File Description SizeFormat Existing users please Login
1-s2.0-S0012821X17304995-main.pdf2.7 MBAdobe PDF
Show full item record

WEB OF SCIENCETM
Citations 20

14
checked on Feb 10, 2021

Page view(s)

391
checked on Apr 24, 2024

Download(s)

7
checked on Apr 24, 2024

Google ScholarTM

Check

Altmetric