SWIPE: a bolometric polarimeter for the Large-Scale Polarization Explorer
Author(s)
Language
English
Obiettivo Specifico
1.10. TTC - Telerilevamento
Status
Published
JCR Journal
N/A or not JCR
Issue/vol(year)
/ 8452 (2012)
Pages (printed)
84523F
Date Issued
2012
Alternative Location
Abstract
The balloon-borne LSPE mission is optimized to measure the linear polarization of the Cosmic Microwave Background
at large angular scales. The Short Wavelength Instrument for the Polarization Explorer (SWIPE) is composed of 3 arrays
of multi-mode bolometers cooled at 0.3K , with optical components and filters cryogenically cooled below 4K to reduce
the background on the detectors. Polarimetry is achieved by means of large rotating half-wave plates and wire-grid
polarizers in front of the arrays. The polarization modulator is the first component of the optical chain, reducing
significantly the effect of instrumental polarization. In SWIPE we trade angular resolution for sensitivity. The diameter
of the entrance pupil of the refractive telescope is 45 cm, while the field optics is optimized to collect tens of modes for
each detector, thus boosting the absorbed power. This approach results in a FWHM resolution of 1.8, 1.5, 1.2 degrees at
95, 145, 245 GHz respectively. The expected performance of the three channels is limited by photon noise, resulting in a
final sensitivity around 0.1-0.2 μK per beam, for a 13 days survey covering 25% of the sky
at large angular scales. The Short Wavelength Instrument for the Polarization Explorer (SWIPE) is composed of 3 arrays
of multi-mode bolometers cooled at 0.3K , with optical components and filters cryogenically cooled below 4K to reduce
the background on the detectors. Polarimetry is achieved by means of large rotating half-wave plates and wire-grid
polarizers in front of the arrays. The polarization modulator is the first component of the optical chain, reducing
significantly the effect of instrumental polarization. In SWIPE we trade angular resolution for sensitivity. The diameter
of the entrance pupil of the refractive telescope is 45 cm, while the field optics is optimized to collect tens of modes for
each detector, thus boosting the absorbed power. This approach results in a FWHM resolution of 1.8, 1.5, 1.2 degrees at
95, 145, 245 GHz respectively. The expected performance of the three channels is limited by photon noise, resulting in a
final sensitivity around 0.1-0.2 μK per beam, for a 13 days survey covering 25% of the sky
Sponsors
Italian Space Agency
References
[1] Reichborn-Kjennerud, B., Aboobaker, A. M. , Ade, et al., ”EBEX: a balloon-borne CMB polarization
experiment”. Proc. SPIE 7741, 77411C (2010)
[2] Filippini, J. P., Ade, P. A. R., Amiri, et al., "SPIDER: a balloon-borne CMB polarimeter for large angular
scales", Proc. SPIE, 7741, 77411N-77411N-12 (2010).
[3] Pagano, L., Cooray, A., Melchiorri A., and Kamionkowski, M., “Red density perturbations and inflationary
gravitational waves”, JCAP, 0804, 009 (2008) and references therein.
[4] The LSPE collaboration: Amico, G., Battistelli, E., Baù, A., et al., these proceedings (2012)
[5] Draine, B. T., and Fraisse, A. A., "Polarized Far-Infrared and Submillimeter Emission from Interstellar Dust",
ApJ, 696, 1-11 (2009)
[6] Martin, P. G., "On Predicting the Polarization of Low Frequency Emission by Diffuse Interstellar Dust", EAS
Publ. Ser., 23, 165-188, (2006)
[7] Benoît, A., P. Ade, A. Amblard, et al., "First detection of polarization of the submillimetre diffuse galactic
dust emission by Archeops", A&A, 424, 571-582, (2004).
[8] Page, L., Hinshaw, G., Komatsu, et al., “Diffuse Source Separation in CMB Observations”, Lecture Notes in
Physics, 665, 159-205 (2009)
[9] Leach, S.M., Cardoso, J.-F., Baccigalupi, C., et al., “Component separation methods for the PLANCK
mission”, Astronomy and Astrophysics, 491, 597-615 (2008)
[10]Bonaldi, A. and Ricciardi, S., "Forecast B-modes detection at large scales in presence of noise and
foregrounds”, MNRAS, 414, 615-620 (2011).
[11]Bersanelli, M., Mennella, A., Morgante, G., et al., “A coherent polarimeter array for the Large Scale
Polarisation Explorer balloon experiment”, these proceedings (2012)
[12] Johnson, B. R., Collins, J., Abroe, M. E., et al., “MAXIPOL: Cosmic Microwave Background Polarimetry
Using a Rotating Half-Wave Plate”, Ap.J., 665, 42–54, (2007)
[13]Arnold, K., Ade, P. A. R., Anthony, A. E., et al., “The POLARBEAR CMB polarization experiment”, Proc.
experiment”. Proc. SPIE 7741, 77411C (2010)
[2] Filippini, J. P., Ade, P. A. R., Amiri, et al., "SPIDER: a balloon-borne CMB polarimeter for large angular
scales", Proc. SPIE, 7741, 77411N-77411N-12 (2010).
[3] Pagano, L., Cooray, A., Melchiorri A., and Kamionkowski, M., “Red density perturbations and inflationary
gravitational waves”, JCAP, 0804, 009 (2008) and references therein.
[4] The LSPE collaboration: Amico, G., Battistelli, E., Baù, A., et al., these proceedings (2012)
[5] Draine, B. T., and Fraisse, A. A., "Polarized Far-Infrared and Submillimeter Emission from Interstellar Dust",
ApJ, 696, 1-11 (2009)
[6] Martin, P. G., "On Predicting the Polarization of Low Frequency Emission by Diffuse Interstellar Dust", EAS
Publ. Ser., 23, 165-188, (2006)
[7] Benoît, A., P. Ade, A. Amblard, et al., "First detection of polarization of the submillimetre diffuse galactic
dust emission by Archeops", A&A, 424, 571-582, (2004).
[8] Page, L., Hinshaw, G., Komatsu, et al., “Diffuse Source Separation in CMB Observations”, Lecture Notes in
Physics, 665, 159-205 (2009)
[9] Leach, S.M., Cardoso, J.-F., Baccigalupi, C., et al., “Component separation methods for the PLANCK
mission”, Astronomy and Astrophysics, 491, 597-615 (2008)
[10]Bonaldi, A. and Ricciardi, S., "Forecast B-modes detection at large scales in presence of noise and
foregrounds”, MNRAS, 414, 615-620 (2011).
[11]Bersanelli, M., Mennella, A., Morgante, G., et al., “A coherent polarimeter array for the Large Scale
Polarisation Explorer balloon experiment”, these proceedings (2012)
[12] Johnson, B. R., Collins, J., Abroe, M. E., et al., “MAXIPOL: Cosmic Microwave Background Polarimetry
Using a Rotating Half-Wave Plate”, Ap.J., 665, 42–54, (2007)
[13]Arnold, K., Ade, P. A. R., Anthony, A. E., et al., “The POLARBEAR CMB polarization experiment”, Proc.
Description
In press. Copyright 2012 Society of Photo-Optical Instrumentation Engineers. One print or electronic copy may be made for personal use only. Systematic reproduction and distribution, duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper are prohibited
Type
article
File(s)![]()
Name
SWIPE a bolometric polarimeter.pdf
Description
main article
Size
719.17 KB
Format
Adobe PDF
Checksum (MD5)
The MD5 message-digest algorithm can be used to verify the integrity of the file that you have uploaded. You can calculate its value locally via tools that are generally available in each operative system like md5sum
38972ebfe21528907e74266ffbd11837