Detecting 1-D and 2-D ground resonances with a single-station approach
Author(s)
Language
English
Obiettivo Specifico
5T. Sismologia, geofisica e geologia per l'ingegneria sismica
Status
Published
JCR Journal
JCR Journal
Peer review journal
Yes
Issue/vol(year)
/223 (2020)
ISSN
0956-540X
Publisher
Oxford University Press - The Royal Astronomical Society
Pages (printed)
471–487
Date Issued
2020
Abstract
The vibration modes of the ground have been described both in the 1-D and 2-D case. The 1-D
resonance is found on geological structures whose aspect ratio is low, that is on layers with a
lateral width much larger than their thickness. A typical example is that of a horizontal soft
sediment layer overlying hard bedrock. In this case, the 1-D resonance frequency, traditionally
detected by means of the microtremor H/V (horizontal to vertical spectral ratio) technique,
depends on the bedrock depth and on the shear wave velocity of the resonating cover layer. The
H/V technique is thus used both to map the resonance frequencies in seismic microzonation
studies and for stratigraphic imaging. When 2-D resonance occurs, generally on deep and
narrow valleys, the whole sedimentary infill vibrates at the same frequency and stratigraphic
imaging can no longer be performed by means of the 1-D resonance equation. Understanding
the 1-D or 2-D resonance nature of a site is therefore mandatory to avoid wrong stratigraphic
and dynamic interpretations, which is in turn extremely relevant for seismic site response
assessment. In this paper, we suggest a procedure to address this issue using single-station approaches,
which are much more common compared to the multistation synchronized approach
presented by research teams in earlier descriptions of the 2-D resonances. We apply the procedure
to the Bolzano sedimentary basin in Northern Italy, which lies at the junction of three
valleys, for which we observed respectively 1-D-only, 1-D and 2-D, and 2-D-only resonances.
We conclude by proposing a workflow scheme to conduct experimental measurements and
data analysis in order to assess the 1-D or 2-D resonance nature of a site using a single-station
approach.
resonance is found on geological structures whose aspect ratio is low, that is on layers with a
lateral width much larger than their thickness. A typical example is that of a horizontal soft
sediment layer overlying hard bedrock. In this case, the 1-D resonance frequency, traditionally
detected by means of the microtremor H/V (horizontal to vertical spectral ratio) technique,
depends on the bedrock depth and on the shear wave velocity of the resonating cover layer. The
H/V technique is thus used both to map the resonance frequencies in seismic microzonation
studies and for stratigraphic imaging. When 2-D resonance occurs, generally on deep and
narrow valleys, the whole sedimentary infill vibrates at the same frequency and stratigraphic
imaging can no longer be performed by means of the 1-D resonance equation. Understanding
the 1-D or 2-D resonance nature of a site is therefore mandatory to avoid wrong stratigraphic
and dynamic interpretations, which is in turn extremely relevant for seismic site response
assessment. In this paper, we suggest a procedure to address this issue using single-station approaches,
which are much more common compared to the multistation synchronized approach
presented by research teams in earlier descriptions of the 2-D resonances. We apply the procedure
to the Bolzano sedimentary basin in Northern Italy, which lies at the junction of three
valleys, for which we observed respectively 1-D-only, 1-D and 2-D, and 2-D-only resonances.
We conclude by proposing a workflow scheme to conduct experimental measurements and
data analysis in order to assess the 1-D or 2-D resonance nature of a site using a single-station
approach.
Description
This article has been accepted for publication in Geophysical Journal International ©: The Authors 2020. Published by Oxford University Press on behalf of the Royal Astronomical Society. All rights reserved. Uploaded in accordance with the publisher's self-archiving policy.
Type
article
File(s)![]()
Name
Sgattoni_Castellaro_GJI_2020.pdf
Size
16.6 MB
Format
Adobe PDF
Checksum (MD5)
The MD5 message-digest algorithm can be used to verify the integrity of the file that you have uploaded. You can calculate its value locally via tools that are generally available in each operative system like md5sum
AA8E7C0F12BB47D9041560EB9BB1F6F3