Identification through seismometric measurements of transients propagating inside the asinelli and garisenda towers (Bologna, Italy), implication on structural
Author(s)
Type
Conference paper
Language
English
Obiettivo Specifico
5T. Sismologia, geofisica e geologia per l'ingegneria sismica
Status
Published
Date Issued
June 24, 2019
Conference Location
Crete, Greece
Publisher
Institute of Structural Analysis and Antiseismic Research School of Civil Engineering National Technical University of Athens (NTUA)
Subjects
seismology for earthquake engineering
Abstract
The SHM has a very important role in the diagnostic process of cultural heritage buildings,
for which generally, the identification of the structural behaviour is affected by many uncer-
tainties. The use of ambient vibration tests allow to characterize the dynamic behavior of the
structures, providing also information to validate numerical modeling. Moreover, continuous
monitoring allows to record streams of seismic ambient noise for long time intervals in order
to retrieve the temporal evolution of the structural characteristics and to highlight the re-
sponse of them to seasonal variations of environmental parameters (temperature, humidity)
and the stresses due to the human activities or to the rapid (daily or weekly) changes in the
ambient conditions (temperature, wind velocity and intensity).
Three seismic monitoring experiments were performed in 2012, 2013 and 2014 at the Asinelli
and Garisenda Towers, two masonry leaning tower built in the center of Bologna (Italy). The
aim of this work is to present the results of the analysis of the data recorded by seismic moni-
toring that allowed to clearly identify the normal modes of oscillation of the Two Towers. A
particular attention was devoted to the identification of transient that, propagating inside the
structures, produce beating effects at the top stations. Implication to the structural modeling
and to the State of health monitoring are discussed.
for which generally, the identification of the structural behaviour is affected by many uncer-
tainties. The use of ambient vibration tests allow to characterize the dynamic behavior of the
structures, providing also information to validate numerical modeling. Moreover, continuous
monitoring allows to record streams of seismic ambient noise for long time intervals in order
to retrieve the temporal evolution of the structural characteristics and to highlight the re-
sponse of them to seasonal variations of environmental parameters (temperature, humidity)
and the stresses due to the human activities or to the rapid (daily or weekly) changes in the
ambient conditions (temperature, wind velocity and intensity).
Three seismic monitoring experiments were performed in 2012, 2013 and 2014 at the Asinelli
and Garisenda Towers, two masonry leaning tower built in the center of Bologna (Italy). The
aim of this work is to present the results of the analysis of the data recorded by seismic moni-
toring that allowed to clearly identify the normal modes of oscillation of the Two Towers. A
particular attention was devoted to the identification of transient that, propagating inside the
structures, produce beating effects at the top stations. Implication to the structural modeling
and to the State of health monitoring are discussed.
References
[1] ISCARSAH (International Scientific Committee for Analysis and Restoration of
Structures of Architectural Heritage), “Recommendations for the analysis, conservation
and structural restoration of Architectural Heritage,” Icomos, no. June, pp. 3–6, 2003.
[2] Guidelines for Evaluation and Mitigation of Seismic Risk to Cultural Heritage,
“Guidelines for Evaluation and Mitigation of Seismic Risk to Cultural Heritage,” Gazz.
Uff., vol. 47, 2011.
[3] F. Cavani, Sulla pendenza e sulla stabilità della torre degli Asinelli di Bologna. 1912.
[4] M. Palermo, S. Silvestri, G. Gasparini, S. Baraccani, and T. Trombetti, “An approach
for the mechanical characterisation of the Asinelli Tower (Bologna) in presence of
insufficient experimental data,” J. Cult. Herit., vol. 16, no. 4, pp. 536–543, 2015.
[5] C. Ceccoli, P. Diotallevi, P. Pozzati, L. Sanpaolesi, and G. Dallavalle, “Indagini
inerenti le strutture murarie e fondali e consolidamento delle parti in elevazione della
Torre Garisenda".” 2001.
[6] G. Francisco, La Torre Garisenda. 2000.
[7] S. Baraccani, M. Palermo, R. M. Azzara, G. Gasparini, S. Silvestri, and T. Trombetti,
Structural interpretation of data from static and dynamic structural health monitoring
of monumental buildings, vol. 747 KEM. 2017.
[8] S. Baraccani, G. Gasparini, M. Palermo, S. Silvestri, and T. Trombetti, “A possible
interpretation of data acquired from monitoring systems,” Civil-Comp Proc., vol. 106,
2014.
[9]
R. M. Azzara, A. Cavaliere, S. Danesi, and A. Morelli, “Il monitoraggio sismico della
Torre degli Asinelli e della Garisenda. Risultati preliminari dell’analisi dei dati.,” 2014.
[10] M. Palermo, S. Silvestri, G. Gasparini, S. Baraccani, and T. Trombetti, “An approach
for the mechanical characterisation of the Asinelli Tower (Bologna) in presence of
insufficient experimental data,” J. Cult. Herit., vol. 16, no. 4, 2015.
[11] M. Palermo et al., “Measurements of the Free Vibration Response of the Asinelli
Tower in Bologna and Its Interpretation,” in Second European Conference on
Earthquake Engineering and Seismology, 2014, pp. 1–12.
Structures of Architectural Heritage), “Recommendations for the analysis, conservation
and structural restoration of Architectural Heritage,” Icomos, no. June, pp. 3–6, 2003.
[2] Guidelines for Evaluation and Mitigation of Seismic Risk to Cultural Heritage,
“Guidelines for Evaluation and Mitigation of Seismic Risk to Cultural Heritage,” Gazz.
Uff., vol. 47, 2011.
[3] F. Cavani, Sulla pendenza e sulla stabilità della torre degli Asinelli di Bologna. 1912.
[4] M. Palermo, S. Silvestri, G. Gasparini, S. Baraccani, and T. Trombetti, “An approach
for the mechanical characterisation of the Asinelli Tower (Bologna) in presence of
insufficient experimental data,” J. Cult. Herit., vol. 16, no. 4, pp. 536–543, 2015.
[5] C. Ceccoli, P. Diotallevi, P. Pozzati, L. Sanpaolesi, and G. Dallavalle, “Indagini
inerenti le strutture murarie e fondali e consolidamento delle parti in elevazione della
Torre Garisenda".” 2001.
[6] G. Francisco, La Torre Garisenda. 2000.
[7] S. Baraccani, M. Palermo, R. M. Azzara, G. Gasparini, S. Silvestri, and T. Trombetti,
Structural interpretation of data from static and dynamic structural health monitoring
of monumental buildings, vol. 747 KEM. 2017.
[8] S. Baraccani, G. Gasparini, M. Palermo, S. Silvestri, and T. Trombetti, “A possible
interpretation of data acquired from monitoring systems,” Civil-Comp Proc., vol. 106,
2014.
[9]
R. M. Azzara, A. Cavaliere, S. Danesi, and A. Morelli, “Il monitoraggio sismico della
Torre degli Asinelli e della Garisenda. Risultati preliminari dell’analisi dei dati.,” 2014.
[10] M. Palermo, S. Silvestri, G. Gasparini, S. Baraccani, and T. Trombetti, “An approach
for the mechanical characterisation of the Asinelli Tower (Bologna) in presence of
insufficient experimental data,” J. Cult. Herit., vol. 16, no. 4, 2015.
[11] M. Palermo et al., “Measurements of the Free Vibration Response of the Asinelli
Tower in Bologna and Its Interpretation,” in Second European Conference on
Earthquake Engineering and Seismology, 2014, pp. 1–12.
File(s)![]()
Name
compdyn_2019.pdf
Size
1.15 MB
Format
Adobe PDF
Checksum (MD5)
The MD5 message-digest algorithm can be used to verify the integrity of the file that you have uploaded. You can calculate its value locally via tools that are generally available in each operative system like md5sum
7b36bb32b6b36deb532071e89f32861e