Item type:Publication, Access status: Restricted , Hydrogen sulfide measurements in air by passive/diffusive samplers and high-frequency analyzer: A critical comparison
(2016-09); ; ; ; In this study, hydrogen sulfide (H2S) measurements in air carried out using (a) passive/diffusive samplers (Radiello® traps) and (b) a high-frequency (60 s) real-time analyzer (Thermo® 450i) were compared in order to evaluate advantages and limitations of the two techniques. Four different sites in urban environments (Florence, Italy) and two volcanic areas characterized by intense degassing of H2S-rich fluids (Campi Flegrei and Vulcano Island, Italy) were selected for such measurements. The concentrations of H2S generally varied over 5 orders of magnitude (from 10 1e103 mg/m3), the H2S values measured with the Radiello® traps (H2SR) being significantly higher than the average values measured by the Thermo® 450i during the trap exposure (H2STa), especially when H2S was <30 mg/m3. To test the reproducibility of the Radiello® traps, 8 passive/diffusive samplers were contemporaneously deployed within an 0.2 m2 area in an H2S-contaminated site at Mt. Amiata (Tuscany, Italy), revealing that the precision of the H2SR values was ±49%. This large uncertainty, whose cause was not recognizable, is to be added to that related to the environmental conditions (wind speed and direction, humidity, temperature), which are known to strongly affect passive measurements. The Thermo® 450i analyzer measurements highlighted the occurrence of short-term temporal variations of the H2S concentrations, with peak values (up to 5732 mg/m3) potentially harmful to the human health. The Radiello® traps were not able to detect such temporal variability due to their large exposure time. The disagreement between the H2SR and H2STa values poses severe concerns for the selection of an appropriate methodological approach aimed to provide an accurate measurement of this highly toxic air pollutant in compliance with the WHO air quality guidelines. Although passive samplers may offer the opportunity to carry out low-cost preliminary surveys, the use of the high-frequency H2S analyzer is preferred when an accurate assessment of air quality is required. In fact, the latter provides precise real-time measurements for a reliable estimation of the effective exposure to hazardous H2S concentrations, giving insights into the mechanisms regulating the dispersion of this air pollutant in relation to the meteorological parameters.506 46 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: Restricted , Origin of methane and light hydrocarbons in natural fluid emissions: A key study from Greece
Greece, a country characterised by intense seismic and volcanic activity, has a complex geodynamic and geological setting that favours the occurrence of many gas manifestations. In this study, we address the origin of CH4 and light hydrocarbons in cold and thermal emissions discharging along the Hellenic territory. Also, we investigate their possible relationship with the main geochemical composition of the gases and the different geological settings of the sampling sites. For this purpose we collected 101 new samples that were analysed for their chemical (O2, N2, CH4, CO2, He, Ne, Ar, H2, H2S and C2-C6 hydrocarbons) and isotopic (R/RA, δ13C-CO2, δ13C-CH4 and δ2H-CH4) composition. Results show that CH4 presents a wide range of concentrations (from<0.5 to 925,200 μmol/mol) and isotopic values (δ13C-CH4 from−79.8 to +45.0‰vs. V-PDB; δ2H-CH4 from−311 to +301‰ vs. V-SMOW). Greece was subdivided in four geologic units (External [EH] and Internal [IH] Hellenides, Hellenic Hinterland [HH] and active Volcanic Arc [VA]) and a decreasing CH4 concentration from EH to HH was recognized, whereas CH4 showed intermediate concentrations in VA. The CH4/(C2H6+C3H8) ratios (from 1.5 to 93,200), coupled with CH4 isotopic features, suggest that the light alkanes derive from different primary sources and are affected by secondary processes. An almost exclusive biotic, mainly microbial, origin of CH4 can be attributed to EH gases. Cold gases at IH have mainly a thermogenic origin, although some gases connected to continental serpentinization may have an abiogenic origin. Methane in gases bubbling in thermal waters of IH, HH and VA and fumarolic gases of the VA seem to have an abiogenic origin, although their chemical and isotopic characteristics may have been produced by secondary oxidation of thermogenic CH4, a process that in some of the sampled gases causes extremely positive isotopic values (δ13C-CH4 up to +45.0‰vs. V-PDB and δ2H-CH4 up to +301‰ vs. V-SMOW).168 181 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: Open Access , GEOCHEMISTRY OF THE GAS MANIFESTATIONS OF GREECE: METHANE AND LIGHT HYDROCARBONS
(Bulletin of the Geological Society of Greece, 2016-05-25); ; ; ; Greece has a very complex geodynamic setting deriving from a long and complicat-ed geological history being characterized by intense seismic activity and enhanced geothermal gradient. This activity, with the contribution of an active volcanic arc, favours the existence of many gas manifestations. Depending on the prevailing gas species, the latter can be subdivided in three main groups: CO2-, N2- and CH4-dominated. In the present work, we focus on methane and light hydrocarbons (C2-C6) to define their origin. CH4 concentrations (<2 to 915,200 μmol/mol) and isotop-ic ratios (δ13C -79.8 to +16.9 ‰, δD -298 to +264‰) cover a wide range of values indicating different origins and/or secondary post-genetic processes. Samples from gas discharged along the Ionian coast and in northern Aegean Sea have a prevail-ing microbial origin. Cold and thermal gas manifestations of central and northern Greece display a prevalent thermogenic origin. Methane in gases released along the active volcanic arc is prevailingly abiogenic, although thermogenic contributions cannot be excluded. Gases collected in the geothermal areas of Sperchios basin and northern Euboea are likely affected by strong secondary oxidation processes, as suggested by their highly positive C and H isotopic values (up to +16.9‰ and +264‰ respectively) and low C1/(C2+C3) ratios.132 162 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Access status: Restricted , A new approach for the measurement of gaseous elemental mercury (GEM) and H2S in air from anthropogenic and natural sources: Examples from Mt. Amiata (Siena, Central Italy) and Solfatara Crater (Campi Flegrei, Southern Italy)
(2017-04); ; ; ; Real-time measurements of GEM and H2S discharged fromnatural and anthropogenic sources are a valuable tool to investigate the dispersion dynamics of these contaminants in air. In this study, a new approach to measure GEM and H2S concentrations in air, carried out by coupling a portable Zeeman atomic absorption spectrometer with high frequency modulation of light polarization (Lumex RA-915M) and a pulsed fluorescence gas analyzer (Thermo Scientific Model 450i), was applied to two distinct areas: (i) in the surroundings of Piancastagnaio (Siena, Central Italy), located in the eastern flanks ofMt. Amiata (a 200,000 years old volcano), where three geothermal plants are operating and whose exhaust gases are dispersed in the atmosphere after passing through the turbines and an abatement system to mitigate the environmental impact on air, and (ii) at Solfatara Crater (Campi Flegrei, Southern Italy), a volcanic apparatus characterized by intense hydrothermal activity. In 2014, seven GEMand H2S surveys were carried out in the two areas along pre-defined pathways performed by car at both the study sites. The lowest and highest recorded GEM and H2S concentrations at Piancastagnaio were up to 194 and 77 ng/m3, respectively, whilst at Solfatara Crater were up to 690 and 3392 μg/m3, respectively. Although the GEM concentrations at Piancastagnaio were lower than the limit value recommended by local regulations for outdoor environment (300 ng/m3), they were almost one order of magnitude higher than the GEM background both in Tuscany (~3.5 ng/m3) and Mt. Amiata (3–5 ng/m3), suggesting that the main source of GEM was likely related to the geothermal plants. At Solfatara Crater, the highest GEM values were recognized in proximity of the main fumarolic gas discharges. As far as the H2S concentrations are concerned, the guideline value of 150 μg/m3, recommended by WHO (2000), was frequently overcome in the study areas. Dot (in the surroundings of Piancastagnaio) and contour (at Solfatara Crater) maps for GEM and H2S concentrations built for each survey highlighted the important effects played by the meteorological parameters, the latter being measured by a Davis® Vantage Vue weather station. In particular, the GEM and H2S plumes were strongly affected by the wind speed and direction thatwere able to modify the dispersion of the two parameters in air in a matter of hours, indicating that the proposed analytical approach is able to produce a more realistic picture of the distribution of these air pollutants than that provided by using passive traps. Finally, the H2S/GEMratio, calculated by normalizing the measured GEM and H2S concentrations to their highest values (nH2S/GEM),was used as a good proxy for the chemical-physical processes that these two gas species can suffer once emitted in the air. In particular, H2S resulted to be more affected by secondary processes than GEM, possibly related to photochemical oxidation reactions.181 11