Options
Rinaldis, D.
Loading...
Preferred name
Rinaldis, D.
2 results
Now showing 1 - 2 of 2
- PublicationOpen AccessLa Microzonazione Sismica della Macroarea 8 (Poggio di Roio, Colle di Roio, Roio Piano, Santa Rufina; AQ): Un esempio d’applicazione di approccio metodologico multidisciplinare.(2009-11-16)
; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ;; ; ; ; ; ; ; ; ; ; ; ; ; ; ; Nell’ambito del Piano di Microzonazione Sismica (di seguito MS) dei Comuni colpiti dal terremoto dell’Aquila in data 6/04/2009, promosso e coordinato dal Dipartimento di Protezione Civile Nazionale con OPCM n. 3772 del 19 maggio 2009, si è costituito un Gruppo di Lavoro (di seguito GdL) al fine di realizzare la MS del territorio denominato Macroarea 8 (di seguito MA8). Il78 30 - PublicationRestrictedRecorded Motions of the Mw6.3 April 6, 2009 L’Aquila (Italy) Earthquake and Implications for Building Structural Damage: Overview.(2010)
; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ;Celebi, M.; USGS ;Bazzurro, P. ;Chiaraluce, L.; Istituto Nazionale di Geofisica e Vulcanologia, Sezione CNT, Roma, Italia ;Clemente, P. ;Decanini, L. ;DedeSortis, A. ;Ellsworth, W.; USGS ;Gorini, A ;Kalkan, E. ;Marcucci, S. ;Milana, G.; Istituto Nazionale di Geofisica e Vulcanologia, Sezione Roma1, Roma, Italia ;Mollaioli, F. ;Olivieri, M.; Istituto Nazionale di Geofisica e Vulcanologia, Sezione CNT, Roma, Italia ;Paolucci, R. ;Rinaldis, D. ;Rovelli, A; Istituto Nazionale di Geofisica e Vulcanologia, Sezione Roma1, Roma, Italia ;Sabetta, F. ;Stephens, C.; ;; ; ; ;; ; ; ;; ;; ; ;; ;The normal-faulting earthquake of 6 April 2009 in the Abruzzo Region of central Italy caused heavy losses of life and substantial damage to centuriesold buildings of significant cultural importance and to modern reinforcedconcrete- framed buildings with hollow masonry infill walls. Although structural deficiencies were significant and widespread, the study of the characteristics of strong motion data from the heavily affected area indicated that the short duration of strong shaking may have spared many more damaged buildings from collapsing. It is recognized that, with this caveat of shortduration shaking, the infill walls may have played a very important role in preventing further deterioration or collapse of many buildings. It is concluded that better new or retrofit construction practices that include reinforcedconcrete shear walls may prove helpful in reducing risks in such seismic areas of Italy, other Mediterranean countries, and even in United States, where there are large inventories of deficient structures.263 27