Please use this identifier to cite or link to this item: http://hdl.handle.net/2122/627
Authors: Vinciguerra, S.* 
Elsworth, D.* 
Malone, S.* 
Title: The 1980 pressure response and flank failure of Mount St. Helens (USA) inferred from seismic scaling exponents
Journal: Journal of Volcanologi and Geothermal Research 
Series/Report no.: 144
Publisher: Elsevier
Issue Date: 2005
DOI: 10.1016/j.jvolgeores.2004.11022
Keywords: seismicity
scaling exponents
haronic inflation
pressurisation mechanics
Subject Classification04. Solid Earth::04.01. Earth Interior::04.01.04. Mineral physics and properties of rocks 
04. Solid Earth::04.08. Volcanology::04.08.02. Experimental volcanism 
04. Solid Earth::04.08. Volcanology::04.08.05. Volcanic rocks 
Abstract: The cataclysmic 18 May 1980 eruption at Mount St. Helens was preceded by intense seismic activity marking the mechanical response of the volcanic edifice to interior pressurisation. This seismicity is analysed to yield the temporal change in the seismic scaling exponent, D, inferred from the seismic b-value, that in-turn is related to the seismic moment of an earthquake. Time evolution of D preceding the eruption onset reveals: (1) a major decrease in D occurring over only a few days at the end of March; (2) a steady but stepped decrease in D (steps ~5–10 days) occurring from the end of March to early May; (3) a sharp decrease in D in early May; and (4) steady low values of D occurring 2–3 days before the eruption onset. This response is interpreted as major ruptures, formed at the end of March, arresting and participating in, but not triggering the ultimate failure of the flank. Rather, the rate of interior fracturing slowed in the 2 months preceding the 18 May 1980 major blast, and the triggering of failure is consistent with interior gas overpressurisation. The occurrence of two swarms of low frequency seismic events and the high values of the harmonic tremor indicate the action of interior pressurisation on a cycle of 20–25 days. Solutions are applied to represent the harmonic interior pressurisation of the edifice by gas exsolving from the volcano core. The transient radial migration of overpressured gas may reduce the apparent strength of the edifice, and ultimately trigger failure of the flank. Importantly, this mechanism is capable of triggering flank failure both after multiple core pressurisation cycles have been sustained, and as core pressures are low and diminishing—and may be a minimum. These twin attributes are both apparent in the seismic record for Mount St. Helens, used as a proxy for the unrecorded timing and magnitude of gas pressurisation at the volcano core.
Appears in Collections:Article published / in press
Article published / in press
Manuscripts

Files in This Item:
File Description SizeFormat Existing users please Login
Vinciguerra S..pdf330.49 kBAdobe PDF
journal volcanology geothermal research.htmredirect - journal volcanology geothermal research497 BHTMLView/Open
Show full item record

Page view(s)

146
checked on Apr 24, 2024

Download(s)

67
checked on Apr 24, 2024

Google ScholarTM

Check

Altmetric