Please use this identifier to cite or link to this item: http://hdl.handle.net/2122/4843
Authors: Vassallo, M.* 
Bobbio, A.* 
Iannaccone, G.* 
Title: A comparison of sea floor and on land seismic ambient noise in the Campi Flegrei caldera (Southern Italy)
Journal: Bulletin of the Seismological Society of America 
Series/Report no.: /98 (2008)
Publisher: Seismological Society of America
Issue Date: Dec-2008
DOI: 10.1785/0120070152
Keywords: Campi Flegrei Caldera
Sea-Floor and On-Land Seismic
Subject Classification04. Solid Earth::04.06. Seismology::04.06.06. Surveys, measurements, and monitoring 
Abstract: The Campi Flegrei (southern Italy) is one of the most active calderas in the world. This caldera is characterized by episodes of slow vertical ground movement, called bradyseism. With several hundred thousand people living within its borders, this area is in a high-risk category should there be an eruption. The seismological monitoring system in the Campi Flegrei is based on nine seismic stations, eight of which are equipped with short-period seismometers (1 Hz), and one with a broadband seismometer (60 sec–50 Hz). While all of the seismic stations are located on land, part of the seismic activity occurs in the undersea area of the Pozzuoli Gulf (Campi Flegrei), where there are no seismic stations. This gap in the data coverage produces a biased and incomplete image of the volcanic area.We carried out an experiment in the Pozzuoli Gulf with the installation of two broadband seismic stations on the seafloor with remote and continuous data acquisition for a duration of 31 days between January and March 2005. Using the data acquired, we have computed the power spectral density (PSD) to characterize the background seismic noise, and to evaluate the true noise variation, we have generated the seismic noise probability density functions from the computed PSD curves. The results of our analysis show that the broadband seismic noise is high when compared with the Peterson noise model (land model), but for periods less than 0.3 sec, the seismic noise on the seafloor is lower than the recordings on land over the same period range. The last bradyseismic crisis (1982–1984) highlights the importance of this frequency range, where most of the spectral content of the recorded earthquakes was observed. Finally, we evaluate the detection threshold of a new seismic station located on the seafloor of the Campi Flegrei caldera considering the characteristics of the local seismicity. This analysis shows that the detection threshold for the sea-floor stations (Mw ∼ 0:2) is less than that for land stations (Mw ∼ 0:8).
Appears in Collections:Article published / in press

Files in This Item:
File Description SizeFormat Existing users please Login
2962.pdf1.82 MBAdobe PDF
Show full item record

WEB OF SCIENCETM
Citations 50

15
checked on Feb 10, 2021

Page view(s)

299
checked on Apr 24, 2024

Download(s)

25
checked on Apr 24, 2024

Google ScholarTM

Check

Altmetric