Please use this identifier to cite or link to this item: http://hdl.handle.net/2122/4000
Authors: Fiorucci, I.* 
Muscari, G.* 
Bianchi, C.* 
Di Girolamo, P.* 
Esposito, F.* 
Grieco, G.* 
Summa, D.* 
Bianchini, G.* 
Palchetti, L.* 
Cacciani, M.* 
Di Iorio, T.* 
Pavese, G.* 
Cimini, D.* 
de Zafra, R.* 
Title: Measurements of low amounts of precipitable water vapor by millimeter wave spectroscopy: An intercomparison with radiosonde, Raman lidar, and Fourier transform infrared data
Journal: Journal of Geophysical Research 
Series/Report no.: / 113 (2008)
Publisher: American Geophysical Union
Issue Date: Jul-2008
DOI: 10.1029/2008JD009831
URL: http://www.agu.org/journals/jd/jd0814/2008JD009831/
Keywords: millimeter wave spectroscopy
column water vapor
Subject Classification01. Atmosphere::01.01. Atmosphere::01.01.01. Composition and Structure 
Abstract: Observations of very low amounts of precipitable water vapor (PWV) by means of the Ground-Based Millimeter wave Spectrometer (GBMS) are discussed. Low amounts of column water vapor (between 0.5 and 4 mm) are typical of high mountain sites and polar regions, especially during winter, and are difficult to measure accurately because of the lack of sensitivity of conventional instruments to such low PWV contents. The technique used involves the measurement of atmospheric opacity in the range between 230 and 280 GHz with a spectral resolution of 4 GHz, followed by the conversion to precipitable water vapor using a linear relationship. We present the intercomparison of this data set with simultaneous PWV observations obtained with Vaisala RS92k radiosondes, a Raman lidar, and an IR Fourier transform spectrometer. These sets of measurements were carried out during the primary field campaign of the Earth Cooling by Water vapor Radiation (ECOWAR) project which took place at Breuil-Cervinia (45.9N, 7.6E, elevation 1990 m) and Plateau Rosa (45.9N, 7.7E, elevation 3490 m), Italy, from 3 to 16 March 2007. GBMS PWV measurements show a good agreement with the other three data sets exhibiting a mean difference between observations of 9%. The considerable number of data points available for the GBMS versus lidar PWV correlation allows an additional analysis which indicates negligible systematic differences between the two data sets.
Appears in Collections:Article published / in press

Files in This Item:
File Description SizeFormat Existing users please Login
2008JD009831.pdfMain article637.02 kBAdobe PDF
Show full item record

WEB OF SCIENCETM
Citations 50

20
checked on Feb 10, 2021

Page view(s) 50

260
checked on Apr 17, 2024

Download(s)

30
checked on Apr 17, 2024

Google ScholarTM

Check

Altmetric